Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling

Detalhes bibliográficos
Autor(a) principal: Pinheiro, Bethânia Camargo
Data de Publicação: 2003
Outros Autores: Bramante, Alexandre Silva, Hussne, Renata Pardini
Tipo de documento: Artigo
Idioma: por
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3137
Resumo: PURPOSE: the purpose of this study was to compare the quality of the obturation and the difference of penetration depth inside the root canal of the instruments Finger Spreader, file type Kerr, Flexofile and Nitiflex when used as spreaders during the filling by Active Lateral Condensation Technique. MATERIAL AND METHOD: 40 extracted permanent human teeth were instrumented by the Modified Goerig Technique and divided in four groups. In the group I the finger spreader was used; in the group II, files type Kerr was used; in the group III, files Flexofile was used and, in the group IV, files Nitiflex, all number 30, for space opening for placement of the secondary cones, during the Technique of Active Lateral Condensation. The radiographic quality of the obturation and the depth of penetration of the instruments was evaluated and analysed statisticaly (Kruskal-Wallis and Dunn's Test). RESULTS AND CONCLUSION: with relationship to the radiograph analysis of the quality of the filling, the group II was what it presented the best result, followed by the groups I, IV and III, respectively. In relation to the depth of penetration of the instruments, the group IV approached more the desired distance, or, 1 millimeter less than the length of the work, followed, respectively, by groups II, III and I.
id USP-17_e0afad1c674033ea1eb10bc412919c6b
oai_identifier_str oai:revistas.usp.br:article/3137
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling Influência da penetração de instrumentos, empregados na condensação lateral ativa, na qualidade da obturação de canais radiculares Root canal obturationDental instrumentsFinger spreaderObturação do canal radicularInstrumentos odontológicosEspaçadores PURPOSE: the purpose of this study was to compare the quality of the obturation and the difference of penetration depth inside the root canal of the instruments Finger Spreader, file type Kerr, Flexofile and Nitiflex when used as spreaders during the filling by Active Lateral Condensation Technique. MATERIAL AND METHOD: 40 extracted permanent human teeth were instrumented by the Modified Goerig Technique and divided in four groups. In the group I the finger spreader was used; in the group II, files type Kerr was used; in the group III, files Flexofile was used and, in the group IV, files Nitiflex, all number 30, for space opening for placement of the secondary cones, during the Technique of Active Lateral Condensation. The radiographic quality of the obturation and the depth of penetration of the instruments was evaluated and analysed statisticaly (Kruskal-Wallis and Dunn's Test). RESULTS AND CONCLUSION: with relationship to the radiograph analysis of the quality of the filling, the group II was what it presented the best result, followed by the groups I, IV and III, respectively. In relation to the depth of penetration of the instruments, the group IV approached more the desired distance, or, 1 millimeter less than the length of the work, followed, respectively, by groups II, III and I. OBJETIVO: comparar a qualidade da obturação e a diferença de profundidade de penetração, no interior do canal radicular, dos espaçadores digitais (Finger Spreader), limas tipo Kerr, Flexofile e Nitiflex, quando utilizados como espaçadores, durante a obturação pela Técnica da Condensação Lateral Ativa. MATERIAL E MÉTODOS: foram utilizados 40 dentes molares permanentes humanos, extraídos, instrumentados pela Técnica de Goerig Modificada e divididos em quatro grupos. No grupo I foi utilizado o espaçador digital C; no grupo II, lima tipo Kerr; no grupo III, lima Flexofile e, no grupo IV, lima Nitiflex, todos com diâmetro (D1) ou diâmetro da ponta correspondente ao diâmetro de uma lima 30 (0,30mm), para abertura de espaço para colocação dos cones secundários, durante a Técnica da Condensação Lateral Ativa. Avaliou-se e submeteu-se à análise estatística (Kruskal-Wallis e teste de Dunn) a qualidade radiográfica da obturação e a profundidade de penetração dos instrumentos. RESULTADOS E CONCLUSÃO: quanto à análise radiográfica da qualidade da obturação, o grupo II foi o que apresentou o melhor resultado, seguido dos grupos I, IV e III, respectivamente. Em relação à profundidade de penetração dos instrumentos, o grupo IV aproximou-se mais da distância desejada, ou seja, 1 milímetro aquém do comprimento de trabalho, seguido, respectivamente, dos grupos II, III e I. Universidade de São Paulo. Faculdade de Odontologia de Bauru2003-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/313710.1590/S1678-77572003000300006Journal of Applied Oral Science; Vol. 11 No. 3 (2003); 186-191 Journal of Applied Oral Science; Vol. 11 Núm. 3 (2003); 186-191 Journal of Applied Oral Science; v. 11 n. 3 (2003); 186-191 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPporhttps://www.revistas.usp.br/jaos/article/view/3137/3826Copyright (c) 2003 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessPinheiro, Bethânia CamargoBramante, Alexandre SilvaHussne, Renata Pardini2012-04-27T11:44:34Zoai:revistas.usp.br:article/3137Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:44:34Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
Influência da penetração de instrumentos, empregados na condensação lateral ativa, na qualidade da obturação de canais radiculares
title Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
spellingShingle Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
Pinheiro, Bethânia Camargo
Root canal obturation
Dental instruments
Finger spreader
Obturação do canal radicular
Instrumentos odontológicos
Espaçadores
title_short Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
title_full Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
title_fullStr Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
title_full_unstemmed Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
title_sort Influence of the penetration of instruments, used in the active lateral condensation, in the quality of root canal filling
author Pinheiro, Bethânia Camargo
author_facet Pinheiro, Bethânia Camargo
Bramante, Alexandre Silva
Hussne, Renata Pardini
author_role author
author2 Bramante, Alexandre Silva
Hussne, Renata Pardini
author2_role author
author
dc.contributor.author.fl_str_mv Pinheiro, Bethânia Camargo
Bramante, Alexandre Silva
Hussne, Renata Pardini
dc.subject.por.fl_str_mv Root canal obturation
Dental instruments
Finger spreader
Obturação do canal radicular
Instrumentos odontológicos
Espaçadores
topic Root canal obturation
Dental instruments
Finger spreader
Obturação do canal radicular
Instrumentos odontológicos
Espaçadores
description PURPOSE: the purpose of this study was to compare the quality of the obturation and the difference of penetration depth inside the root canal of the instruments Finger Spreader, file type Kerr, Flexofile and Nitiflex when used as spreaders during the filling by Active Lateral Condensation Technique. MATERIAL AND METHOD: 40 extracted permanent human teeth were instrumented by the Modified Goerig Technique and divided in four groups. In the group I the finger spreader was used; in the group II, files type Kerr was used; in the group III, files Flexofile was used and, in the group IV, files Nitiflex, all number 30, for space opening for placement of the secondary cones, during the Technique of Active Lateral Condensation. The radiographic quality of the obturation and the depth of penetration of the instruments was evaluated and analysed statisticaly (Kruskal-Wallis and Dunn's Test). RESULTS AND CONCLUSION: with relationship to the radiograph analysis of the quality of the filling, the group II was what it presented the best result, followed by the groups I, IV and III, respectively. In relation to the depth of penetration of the instruments, the group IV approached more the desired distance, or, 1 millimeter less than the length of the work, followed, respectively, by groups II, III and I.
publishDate 2003
dc.date.none.fl_str_mv 2003-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3137
10.1590/S1678-77572003000300006
url https://www.revistas.usp.br/jaos/article/view/3137
identifier_str_mv 10.1590/S1678-77572003000300006
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3137/3826
dc.rights.driver.fl_str_mv Copyright (c) 2003 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2003 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 11 No. 3 (2003); 186-191
Journal of Applied Oral Science; Vol. 11 Núm. 3 (2003); 186-191
Journal of Applied Oral Science; v. 11 n. 3 (2003); 186-191
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221671218479104