Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching

Detalhes bibliográficos
Autor(a) principal: STEINHAUSER, Henrique Caballero
Data de Publicação: 2014
Outros Autores: TURSSI, Cecília Pedroso, FRANÇA, Fabiana Mantovani Gomes, AMARAL, Flávia Lucisano Botelho do, BASTING, Roberta Tarkany
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/80548
Resumo: Objective: The aim of this study was to evaluate the effect of feldspathic ceramic surface cleaning on micro-shear bond strength and ceramic surface morphology. Material and Methods: Forty discs of feldspathic ceramic were prepared and etched with 10% hydrofluoric acid for 2 minutes. The discs were randomly distributed into five groups (n=8): C: no treatment, S: water spray + air drying for 1 minute, US: immersion in ultrasonic bath for 5 minutes, F: etching with 37% phosphoric acid for 1 minute, followed by 1-minute rinse, F+US: etching with 37% phosphoric acid for 1 minute, 1-minute rinse and ultrasonic bath for 5 minutes. Composite cylinders were bonded to the discs following application of silane and hydrophobic adhesive for micro-shear bond strength testing in a universal testing machine at 0.5 mm/min crosshead speed until failure. Stereomicroscopy was used to classify failure type. Surface micromorphology of each treatment type was evaluated by scanning electron microscopy at 500 and 2,500 times magnification. Results: One-way ANOVA test showed no significant difference between treatments (p=0.3197) and the most common failure types were cohesive resin cohesion followed by adhesive failure. Micro-shear bond strength of the feldspathic ceramic substrate to the adhesive system was not influenced by the different surface cleaning techniques. Absence of or less residue was observed after etching with hydrofluoric acid for the groups US and F+US. Conclusions: Combining ceramic cleaning techniques with hydrofluoric acid etching did not affect ceramic bond strength, whereas, when cleaning was associated with ultrasound, less residue was observed.
id USP-17_e3ba4a3cf97c5cbb42704ec0348a56d3
oai_identifier_str oai:revistas.usp.br:article/80548
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching Objective: The aim of this study was to evaluate the effect of feldspathic ceramic surface cleaning on micro-shear bond strength and ceramic surface morphology. Material and Methods: Forty discs of feldspathic ceramic were prepared and etched with 10% hydrofluoric acid for 2 minutes. The discs were randomly distributed into five groups (n=8): C: no treatment, S: water spray + air drying for 1 minute, US: immersion in ultrasonic bath for 5 minutes, F: etching with 37% phosphoric acid for 1 minute, followed by 1-minute rinse, F+US: etching with 37% phosphoric acid for 1 minute, 1-minute rinse and ultrasonic bath for 5 minutes. Composite cylinders were bonded to the discs following application of silane and hydrophobic adhesive for micro-shear bond strength testing in a universal testing machine at 0.5 mm/min crosshead speed until failure. Stereomicroscopy was used to classify failure type. Surface micromorphology of each treatment type was evaluated by scanning electron microscopy at 500 and 2,500 times magnification. Results: One-way ANOVA test showed no significant difference between treatments (p=0.3197) and the most common failure types were cohesive resin cohesion followed by adhesive failure. Micro-shear bond strength of the feldspathic ceramic substrate to the adhesive system was not influenced by the different surface cleaning techniques. Absence of or less residue was observed after etching with hydrofluoric acid for the groups US and F+US. Conclusions: Combining ceramic cleaning techniques with hydrofluoric acid etching did not affect ceramic bond strength, whereas, when cleaning was associated with ultrasound, less residue was observed. Universidade de São Paulo. Faculdade de Odontologia de Bauru2014-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/8054810.1590/1678-775720130339Journal of Applied Oral Science; Vol. 22 No. 2 (2014); 85-90Journal of Applied Oral Science; Vol. 22 Núm. 2 (2014); 85-90Journal of Applied Oral Science; v. 22 n. 2 (2014); 85-901678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/80548/84211Copyright (c) 2014 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessSTEINHAUSER, Henrique Caballero TURSSI, Cecília Pedroso FRANÇA, Fabiana Mantovani Gomes AMARAL, Flávia Lucisano Botelho do BASTING, Roberta Tarkany 2014-05-08T13:29:51Zoai:revistas.usp.br:article/80548Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2014-05-08T13:29:51Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
title Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
spellingShingle Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
STEINHAUSER, Henrique Caballero
title_short Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
title_full Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
title_fullStr Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
title_full_unstemmed Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
title_sort Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
author STEINHAUSER, Henrique Caballero
author_facet STEINHAUSER, Henrique Caballero
TURSSI, Cecília Pedroso
FRANÇA, Fabiana Mantovani Gomes
AMARAL, Flávia Lucisano Botelho do
BASTING, Roberta Tarkany
author_role author
author2 TURSSI, Cecília Pedroso
FRANÇA, Fabiana Mantovani Gomes
AMARAL, Flávia Lucisano Botelho do
BASTING, Roberta Tarkany
author2_role author
author
author
author
dc.contributor.author.fl_str_mv STEINHAUSER, Henrique Caballero
TURSSI, Cecília Pedroso
FRANÇA, Fabiana Mantovani Gomes
AMARAL, Flávia Lucisano Botelho do
BASTING, Roberta Tarkany
description Objective: The aim of this study was to evaluate the effect of feldspathic ceramic surface cleaning on micro-shear bond strength and ceramic surface morphology. Material and Methods: Forty discs of feldspathic ceramic were prepared and etched with 10% hydrofluoric acid for 2 minutes. The discs were randomly distributed into five groups (n=8): C: no treatment, S: water spray + air drying for 1 minute, US: immersion in ultrasonic bath for 5 minutes, F: etching with 37% phosphoric acid for 1 minute, followed by 1-minute rinse, F+US: etching with 37% phosphoric acid for 1 minute, 1-minute rinse and ultrasonic bath for 5 minutes. Composite cylinders were bonded to the discs following application of silane and hydrophobic adhesive for micro-shear bond strength testing in a universal testing machine at 0.5 mm/min crosshead speed until failure. Stereomicroscopy was used to classify failure type. Surface micromorphology of each treatment type was evaluated by scanning electron microscopy at 500 and 2,500 times magnification. Results: One-way ANOVA test showed no significant difference between treatments (p=0.3197) and the most common failure types were cohesive resin cohesion followed by adhesive failure. Micro-shear bond strength of the feldspathic ceramic substrate to the adhesive system was not influenced by the different surface cleaning techniques. Absence of or less residue was observed after etching with hydrofluoric acid for the groups US and F+US. Conclusions: Combining ceramic cleaning techniques with hydrofluoric acid etching did not affect ceramic bond strength, whereas, when cleaning was associated with ultrasound, less residue was observed.
publishDate 2014
dc.date.none.fl_str_mv 2014-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/80548
10.1590/1678-775720130339
url https://www.revistas.usp.br/jaos/article/view/80548
identifier_str_mv 10.1590/1678-775720130339
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/80548/84211
dc.rights.driver.fl_str_mv Copyright (c) 2014 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2014 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 22 No. 2 (2014); 85-90
Journal of Applied Oral Science; Vol. 22 Núm. 2 (2014); 85-90
Journal of Applied Oral Science; v. 22 n. 2 (2014); 85-90
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221678116012032