Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572019000100426 |
Resumo: | Abstract Pain due to administration of local anesthetics is the primary reason for patients' fear and anxiety, and various methods are used to minimize it. This study aimed to measure the degree of pain during administration of anesthesia and determine the latency time and duration of pulpal anesthesia using two anesthetic methods in the maxilla. Materials and Methods: A randomized, single-blind, split-mouth clinical trial was conducted with 41 volunteers who required class I restorations in the maxillary first molars. Local anesthesia was administered with a needleless jet injection system (experimental group) or with a carpule syringe (control) using a 30-gauge short needle. The method of anesthesia and laterality of the maxilla were randomized. A pulp electric tester measured the latency time and duration of anesthesia in the second molar. Visual analogue scale (VAS) was used to measure the degree of pain during the anesthetic method. Data were tabulated and then analyzed by a statistician. The t-test was used to analyze the differences between the groups for basal electrical stimulation. Duration of anesthesia and degree of pain were compared using the Mann-Whitney test. A 5% significance level was considered. Results: There was no statistical difference in the basal electrical stimulation threshold (mA) and degree of pain between the two methods of anesthesia (p>0.05). Latency time was 2 minutes for all subjects. The duration of pulpal anesthesia showed no statistical difference (minutes) between the two methods (p<0.001), with a longer duration for the traditional method of anesthesia (median of 40 minutes). Conclusions: The two anesthetics methods did not differ concerning the pain experienced during anesthesia. Latency lasted 2 minutes for all subjects; the traditional infiltration anesthesia resulted in a longer anesthetic duration compared with the needleless jet injection. |
id |
USP-17_ed13a33c4ed20b869230e0ef0e3aca76 |
---|---|
oai_identifier_str |
oai:scielo:S1678-77572019000100426 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trialAnesthesiadentalDental pulpPainAbstract Pain due to administration of local anesthetics is the primary reason for patients' fear and anxiety, and various methods are used to minimize it. This study aimed to measure the degree of pain during administration of anesthesia and determine the latency time and duration of pulpal anesthesia using two anesthetic methods in the maxilla. Materials and Methods: A randomized, single-blind, split-mouth clinical trial was conducted with 41 volunteers who required class I restorations in the maxillary first molars. Local anesthesia was administered with a needleless jet injection system (experimental group) or with a carpule syringe (control) using a 30-gauge short needle. The method of anesthesia and laterality of the maxilla were randomized. A pulp electric tester measured the latency time and duration of anesthesia in the second molar. Visual analogue scale (VAS) was used to measure the degree of pain during the anesthetic method. Data were tabulated and then analyzed by a statistician. The t-test was used to analyze the differences between the groups for basal electrical stimulation. Duration of anesthesia and degree of pain were compared using the Mann-Whitney test. A 5% significance level was considered. Results: There was no statistical difference in the basal electrical stimulation threshold (mA) and degree of pain between the two methods of anesthesia (p>0.05). Latency time was 2 minutes for all subjects. The duration of pulpal anesthesia showed no statistical difference (minutes) between the two methods (p<0.001), with a longer duration for the traditional method of anesthesia (median of 40 minutes). Conclusions: The two anesthetics methods did not differ concerning the pain experienced during anesthesia. Latency lasted 2 minutes for all subjects; the traditional infiltration anesthesia resulted in a longer anesthetic duration compared with the needleless jet injection.Faculdade De Odontologia De Bauru - USP2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572019000100426Journal of Applied Oral Science v.27 2019reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/1678-7757-2018-0195info:eu-repo/semantics/openAccessOliveira,Allan Carlos Araújo deAmorim,Klinger de SouzaNascimento Júnior,Edmundo Marques doDuarte,Amanda Caroline BatistaGroppo,Francisco CarlosTakeshita,Wilton MitsunariSouza,Liane Maciel de Almeidaeng2019-01-17T00:00:00Zoai:scielo:S1678-77572019000100426Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2019-01-17T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial |
title |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial |
spellingShingle |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial Oliveira,Allan Carlos Araújo de Anesthesia dental Dental pulp Pain |
title_short |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial |
title_full |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial |
title_fullStr |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial |
title_full_unstemmed |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial |
title_sort |
Assessment of anesthetic properties and pain during needleless jet injection anesthesia: a randomized clinical trial |
author |
Oliveira,Allan Carlos Araújo de |
author_facet |
Oliveira,Allan Carlos Araújo de Amorim,Klinger de Souza Nascimento Júnior,Edmundo Marques do Duarte,Amanda Caroline Batista Groppo,Francisco Carlos Takeshita,Wilton Mitsunari Souza,Liane Maciel de Almeida |
author_role |
author |
author2 |
Amorim,Klinger de Souza Nascimento Júnior,Edmundo Marques do Duarte,Amanda Caroline Batista Groppo,Francisco Carlos Takeshita,Wilton Mitsunari Souza,Liane Maciel de Almeida |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Oliveira,Allan Carlos Araújo de Amorim,Klinger de Souza Nascimento Júnior,Edmundo Marques do Duarte,Amanda Caroline Batista Groppo,Francisco Carlos Takeshita,Wilton Mitsunari Souza,Liane Maciel de Almeida |
dc.subject.por.fl_str_mv |
Anesthesia dental Dental pulp Pain |
topic |
Anesthesia dental Dental pulp Pain |
description |
Abstract Pain due to administration of local anesthetics is the primary reason for patients' fear and anxiety, and various methods are used to minimize it. This study aimed to measure the degree of pain during administration of anesthesia and determine the latency time and duration of pulpal anesthesia using two anesthetic methods in the maxilla. Materials and Methods: A randomized, single-blind, split-mouth clinical trial was conducted with 41 volunteers who required class I restorations in the maxillary first molars. Local anesthesia was administered with a needleless jet injection system (experimental group) or with a carpule syringe (control) using a 30-gauge short needle. The method of anesthesia and laterality of the maxilla were randomized. A pulp electric tester measured the latency time and duration of anesthesia in the second molar. Visual analogue scale (VAS) was used to measure the degree of pain during the anesthetic method. Data were tabulated and then analyzed by a statistician. The t-test was used to analyze the differences between the groups for basal electrical stimulation. Duration of anesthesia and degree of pain were compared using the Mann-Whitney test. A 5% significance level was considered. Results: There was no statistical difference in the basal electrical stimulation threshold (mA) and degree of pain between the two methods of anesthesia (p>0.05). Latency time was 2 minutes for all subjects. The duration of pulpal anesthesia showed no statistical difference (minutes) between the two methods (p<0.001), with a longer duration for the traditional method of anesthesia (median of 40 minutes). Conclusions: The two anesthetics methods did not differ concerning the pain experienced during anesthesia. Latency lasted 2 minutes for all subjects; the traditional infiltration anesthesia resulted in a longer anesthetic duration compared with the needleless jet injection. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572019000100426 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572019000100426 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1678-7757-2018-0195 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science v.27 2019 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1748936440036720640 |