Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Clinics |
Texto Completo: | https://www.revistas.usp.br/clinics/article/view/17829 |
Resumo: | PURPOSE: To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS: Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSureTM wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively). Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at p |
id |
USP-19_11927c6d76e2ad7d78ee1fb8d191f825 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/17829 |
network_acronym_str |
USP-19 |
network_name_str |
Clinics |
repository_id_str |
|
spelling |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm Post-exclusionEndoleakEndoprosthesisPressure measurementsAneurysm sac PURPOSE: To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS: Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSureTM wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively). Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at pHospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo2008-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/clinics/article/view/1782910.1590/S1807-59322008000100011Clinics; Vol. 63 No. 1 (2008); 59-66 Clinics; v. 63 n. 1 (2008); 59-66 Clinics; Vol. 63 Núm. 1 (2008); 59-66 1980-53221807-5932reponame:Clinicsinstname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/clinics/article/view/17829/19894Silveira, Pierre GalvagniMiller, Christopher William TeixeiraMendes, Rafael FreygangGalego, Gilberto Nascimentoinfo:eu-repo/semantics/openAccess2012-05-22T18:36:45Zoai:revistas.usp.br:article/17829Revistahttps://www.revistas.usp.br/clinicsPUBhttps://www.revistas.usp.br/clinics/oai||clinics@hc.fm.usp.br1980-53221807-5932opendoar:2012-05-22T18:36:45Clinics - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm |
title |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm |
spellingShingle |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm Silveira, Pierre Galvagni Post-exclusion Endoleak Endoprosthesis Pressure measurements Aneurysm sac |
title_short |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm |
title_full |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm |
title_fullStr |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm |
title_full_unstemmed |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm |
title_sort |
Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm |
author |
Silveira, Pierre Galvagni |
author_facet |
Silveira, Pierre Galvagni Miller, Christopher William Teixeira Mendes, Rafael Freygang Galego, Gilberto Nascimento |
author_role |
author |
author2 |
Miller, Christopher William Teixeira Mendes, Rafael Freygang Galego, Gilberto Nascimento |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Silveira, Pierre Galvagni Miller, Christopher William Teixeira Mendes, Rafael Freygang Galego, Gilberto Nascimento |
dc.subject.por.fl_str_mv |
Post-exclusion Endoleak Endoprosthesis Pressure measurements Aneurysm sac |
topic |
Post-exclusion Endoleak Endoprosthesis Pressure measurements Aneurysm sac |
description |
PURPOSE: To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS: Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSureTM wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively). Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at p |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/clinics/article/view/17829 10.1590/S1807-59322008000100011 |
url |
https://www.revistas.usp.br/clinics/article/view/17829 |
identifier_str_mv |
10.1590/S1807-59322008000100011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/clinics/article/view/17829/19894 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo |
publisher.none.fl_str_mv |
Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo |
dc.source.none.fl_str_mv |
Clinics; Vol. 63 No. 1 (2008); 59-66 Clinics; v. 63 n. 1 (2008); 59-66 Clinics; Vol. 63 Núm. 1 (2008); 59-66 1980-5322 1807-5932 reponame:Clinics instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Clinics |
collection |
Clinics |
repository.name.fl_str_mv |
Clinics - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||clinics@hc.fm.usp.br |
_version_ |
1800222753934016512 |