Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study

Detalhes bibliográficos
Autor(a) principal: Zuhur, Sayid Shafi
Data de Publicação: 2012
Outros Autores: Özel, Alper, Velet, Selvinaz, Buğdacı, Mehmet Sait, Çil, Esra, Altuntas, Yüksel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Clinics
Texto Completo: https://www.revistas.usp.br/clinics/article/view/19677
Resumo: OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 ageand sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with colorflow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.
id USP-19_a70183098be036897e9be11d2be47fd1
oai_identifier_str oai:revistas.usp.br:article/19677
network_acronym_str USP-19
network_name_str Clinics
repository_id_str
spelling Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective studyGestational transient thyrotoxicosisGraves' diseaseInferior thyroid arteryColor-flow Doppler ultrasonographyPregnancyOBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 ageand sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with colorflow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo2012-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/clinics/article/view/1967710.6061/clinics/2012(02)06Clinics; Vol. 67 No. 2 (2012); 125-129Clinics; v. 67 n. 2 (2012); 125-129Clinics; Vol. 67 Núm. 2 (2012); 125-1291980-53221807-5932reponame:Clinicsinstname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/clinics/article/view/19677/21741Zuhur, Sayid ShafiÖzel, AlperVelet, SelvinazBuğdacı, Mehmet SaitÇil, EsraAltuntas, Yükselinfo:eu-repo/semantics/openAccess2012-05-24T18:50:33Zoai:revistas.usp.br:article/19677Revistahttps://www.revistas.usp.br/clinicsPUBhttps://www.revistas.usp.br/clinics/oai||clinics@hc.fm.usp.br1980-53221807-5932opendoar:2012-05-24T18:50:33Clinics - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
title Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
spellingShingle Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
Zuhur, Sayid Shafi
Gestational transient thyrotoxicosis
Graves' disease
Inferior thyroid artery
Color-flow Doppler ultrasonography
Pregnancy
title_short Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
title_full Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
title_fullStr Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
title_full_unstemmed Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
title_sort Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study
author Zuhur, Sayid Shafi
author_facet Zuhur, Sayid Shafi
Özel, Alper
Velet, Selvinaz
Buğdacı, Mehmet Sait
Çil, Esra
Altuntas, Yüksel
author_role author
author2 Özel, Alper
Velet, Selvinaz
Buğdacı, Mehmet Sait
Çil, Esra
Altuntas, Yüksel
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Zuhur, Sayid Shafi
Özel, Alper
Velet, Selvinaz
Buğdacı, Mehmet Sait
Çil, Esra
Altuntas, Yüksel
dc.subject.por.fl_str_mv Gestational transient thyrotoxicosis
Graves' disease
Inferior thyroid artery
Color-flow Doppler ultrasonography
Pregnancy
topic Gestational transient thyrotoxicosis
Graves' disease
Inferior thyroid artery
Color-flow Doppler ultrasonography
Pregnancy
description OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 ageand sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with colorflow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.
publishDate 2012
dc.date.none.fl_str_mv 2012-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/clinics/article/view/19677
10.6061/clinics/2012(02)06
url https://www.revistas.usp.br/clinics/article/view/19677
identifier_str_mv 10.6061/clinics/2012(02)06
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/clinics/article/view/19677/21741
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
dc.source.none.fl_str_mv Clinics; Vol. 67 No. 2 (2012); 125-129
Clinics; v. 67 n. 2 (2012); 125-129
Clinics; Vol. 67 Núm. 2 (2012); 125-129
1980-5322
1807-5932
reponame:Clinics
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Clinics
collection Clinics
repository.name.fl_str_mv Clinics - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||clinics@hc.fm.usp.br
_version_ 1800222758236323840