The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis

Detalhes bibliográficos
Autor(a) principal: Xu, Qi
Data de Publicação: 2023
Outros Autores: Wang, Jiale, Wang, Jing, Guo, Runzhao, Qian, Yao, Liu, Feng
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Clinics
Texto Completo: https://www.revistas.usp.br/clinics/article/view/214060
Resumo: Objective: This study aimed to perform a meta-analysis to investigate the diagnostic safety and accuracy of Ultrasound-Guided Core Needle Biopsy (US-CNB) Axillary Lymph Nodes (ALNs) region in patients with Breast Cancer (BC). Methods: The authors searched the electronic databases PubMed, Scopus, Embase, and Web of Science for clinical trials about US-CNB for the detection of ALNs in breast cancer patients. The authors extracted and pooled raw data from the included studies and performed statistical analyses using Meta-DiSc 1.4 and Review Manager 5.3 software. A random effects model was used to calculate the data. At the same time, data from the Ultrasound-guided Fine-Needle Aspiration (US-FNA) were introduced for comparison with the US-CNB. In addition, the subgroup was performed to explore the causes of heterogeneity. (PROSPERO ID: CRD42022369491). Results: In total, 18 articles with 2521 patients were assessed as meeting the study criteria. The overall sensitivity was 0.90 (95% CI [Confidence Interval], 0.87‒0.91; p = 0.00), the overall specificity was 0.99 (95% CI 0.98‒1.00; p = 0.62), the overall area under the curve (AUC) was 0.98. Next, in the comparison of US-CNB and US-FNA, US-CNB is better than US-FNA in the diagnosis of ALNs metastases. The sensitivity was 0.88 (95% CI 0.84‒0.91; p = 0.12) vs. 0.73 (95% CI 0.69‒0.76; p = 0.91), the specificity was 1.00 (95% CI 0.99‒1.00; p = 1.00) vs. 0.99 (95% CI 0.67‒0.74; p = 0.92), and the AUC was 0.99 vs. 0.98. Subgroup analysis showed that heterogeneity may be related to preoperative Neoadjuvant Chemotherapy (NAC) treatment, region, size of tumor diameter, and the number of punctures. Conclusion: US-CNB has a satisfactory diagnostic performance with good specificity and sensitivity in the preoperative diagnosis of ALNs in BC patients.
id USP-19_d3ad4b6424355167eed55e55b31fb808
oai_identifier_str oai:revistas.usp.br:article/214060
network_acronym_str USP-19
network_name_str Clinics
repository_id_str
spelling The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysisCore needle biopsyBreast cancerMeta-analysisDiagnosticAxillary lymph nodesObjective: This study aimed to perform a meta-analysis to investigate the diagnostic safety and accuracy of Ultrasound-Guided Core Needle Biopsy (US-CNB) Axillary Lymph Nodes (ALNs) region in patients with Breast Cancer (BC). Methods: The authors searched the electronic databases PubMed, Scopus, Embase, and Web of Science for clinical trials about US-CNB for the detection of ALNs in breast cancer patients. The authors extracted and pooled raw data from the included studies and performed statistical analyses using Meta-DiSc 1.4 and Review Manager 5.3 software. A random effects model was used to calculate the data. At the same time, data from the Ultrasound-guided Fine-Needle Aspiration (US-FNA) were introduced for comparison with the US-CNB. In addition, the subgroup was performed to explore the causes of heterogeneity. (PROSPERO ID: CRD42022369491). Results: In total, 18 articles with 2521 patients were assessed as meeting the study criteria. The overall sensitivity was 0.90 (95% CI [Confidence Interval], 0.87‒0.91; p = 0.00), the overall specificity was 0.99 (95% CI 0.98‒1.00; p = 0.62), the overall area under the curve (AUC) was 0.98. Next, in the comparison of US-CNB and US-FNA, US-CNB is better than US-FNA in the diagnosis of ALNs metastases. The sensitivity was 0.88 (95% CI 0.84‒0.91; p = 0.12) vs. 0.73 (95% CI 0.69‒0.76; p = 0.91), the specificity was 1.00 (95% CI 0.99‒1.00; p = 1.00) vs. 0.99 (95% CI 0.67‒0.74; p = 0.92), and the AUC was 0.99 vs. 0.98. Subgroup analysis showed that heterogeneity may be related to preoperative Neoadjuvant Chemotherapy (NAC) treatment, region, size of tumor diameter, and the number of punctures. Conclusion: US-CNB has a satisfactory diagnostic performance with good specificity and sensitivity in the preoperative diagnosis of ALNs in BC patients.Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo2023-05-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/clinics/article/view/21406010.1016/j.clinsp.2023.100207Clinics; Vol. 78 (2023); 100207Clinics; v. 78 (2023); 100207Clinics; Vol. 78 (2023); 1002071980-53221807-5932reponame:Clinicsinstname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/clinics/article/view/214060/196291Copyright (c) 2023 Clinicsinfo:eu-repo/semantics/openAccessXu, QiWang, JialeWang, JingGuo, RunzhaoQian, YaoLiu, Feng2023-07-06T13:05:36Zoai:revistas.usp.br:article/214060Revistahttps://www.revistas.usp.br/clinicsPUBhttps://www.revistas.usp.br/clinics/oai||clinics@hc.fm.usp.br1980-53221807-5932opendoar:2023-07-06T13:05:36Clinics - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
title The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
spellingShingle The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
Xu, Qi
Core needle biopsy
Breast cancer
Meta-analysis
Diagnostic
Axillary lymph nodes
title_short The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
title_full The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
title_fullStr The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
title_full_unstemmed The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
title_sort The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
author Xu, Qi
author_facet Xu, Qi
Wang, Jiale
Wang, Jing
Guo, Runzhao
Qian, Yao
Liu, Feng
author_role author
author2 Wang, Jiale
Wang, Jing
Guo, Runzhao
Qian, Yao
Liu, Feng
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Xu, Qi
Wang, Jiale
Wang, Jing
Guo, Runzhao
Qian, Yao
Liu, Feng
dc.subject.por.fl_str_mv Core needle biopsy
Breast cancer
Meta-analysis
Diagnostic
Axillary lymph nodes
topic Core needle biopsy
Breast cancer
Meta-analysis
Diagnostic
Axillary lymph nodes
description Objective: This study aimed to perform a meta-analysis to investigate the diagnostic safety and accuracy of Ultrasound-Guided Core Needle Biopsy (US-CNB) Axillary Lymph Nodes (ALNs) region in patients with Breast Cancer (BC). Methods: The authors searched the electronic databases PubMed, Scopus, Embase, and Web of Science for clinical trials about US-CNB for the detection of ALNs in breast cancer patients. The authors extracted and pooled raw data from the included studies and performed statistical analyses using Meta-DiSc 1.4 and Review Manager 5.3 software. A random effects model was used to calculate the data. At the same time, data from the Ultrasound-guided Fine-Needle Aspiration (US-FNA) were introduced for comparison with the US-CNB. In addition, the subgroup was performed to explore the causes of heterogeneity. (PROSPERO ID: CRD42022369491). Results: In total, 18 articles with 2521 patients were assessed as meeting the study criteria. The overall sensitivity was 0.90 (95% CI [Confidence Interval], 0.87‒0.91; p = 0.00), the overall specificity was 0.99 (95% CI 0.98‒1.00; p = 0.62), the overall area under the curve (AUC) was 0.98. Next, in the comparison of US-CNB and US-FNA, US-CNB is better than US-FNA in the diagnosis of ALNs metastases. The sensitivity was 0.88 (95% CI 0.84‒0.91; p = 0.12) vs. 0.73 (95% CI 0.69‒0.76; p = 0.91), the specificity was 1.00 (95% CI 0.99‒1.00; p = 1.00) vs. 0.99 (95% CI 0.67‒0.74; p = 0.92), and the AUC was 0.99 vs. 0.98. Subgroup analysis showed that heterogeneity may be related to preoperative Neoadjuvant Chemotherapy (NAC) treatment, region, size of tumor diameter, and the number of punctures. Conclusion: US-CNB has a satisfactory diagnostic performance with good specificity and sensitivity in the preoperative diagnosis of ALNs in BC patients.
publishDate 2023
dc.date.none.fl_str_mv 2023-05-02
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/clinics/article/view/214060
10.1016/j.clinsp.2023.100207
url https://www.revistas.usp.br/clinics/article/view/214060
identifier_str_mv 10.1016/j.clinsp.2023.100207
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/clinics/article/view/214060/196291
dc.rights.driver.fl_str_mv Copyright (c) 2023 Clinics
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2023 Clinics
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
dc.source.none.fl_str_mv Clinics; Vol. 78 (2023); 100207
Clinics; v. 78 (2023); 100207
Clinics; Vol. 78 (2023); 100207
1980-5322
1807-5932
reponame:Clinics
instname:Universidade de São Paulo (USP)