Usability of volumetric infusion pumps in pediatric intensive care

Detalhes bibliográficos
Autor(a) principal: Oliveira,Elizandra Cassia da Silva
Data de Publicação: 2021
Outros Autores: Silva,Roberto Carlos Lyra da, Arruda,Gustavo Aires de, Oliveira,Regina Célia de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista da Escola de Enfermagem da USP (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0080-62342021000100429
Resumo: ABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to September 2018. The Methodological Guideline for Medical Care Equipment Assessment Studies and the quality model proposed by NBR ISO/IEC 9126-1 were followed. Descriptive statistical analysis was used applying Fisher’s exact test, binomial test and Mann-Whitney test. Results: 91.7% of tasks were completed. The infusion pump-2 model was associated (p < 0.001) with operationalization, tasks accomplished with non-conformities, use of a manual calculator (measure effectiveness) and task accomplishment time (measure efficiency). Conclusion: Efficacy and efficiency measures can evidence a better context of usability of IPs and identify interaction failures with the nursing staff to be improved in care practice.
id USP-24_d39c79e3ae74caea80d8115f79d5c7b8
oai_identifier_str oai:scielo:S0080-62342021000100429
network_acronym_str USP-24
network_name_str Revista da Escola de Enfermagem da USP (Online)
repository_id_str
spelling Usability of volumetric infusion pumps in pediatric intensive careInfusion PumpsIntensive Care Units, PediatricErgonomicsPediatric NursingQuality of Health CareTechnology Assessment, BiomedicalABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to September 2018. The Methodological Guideline for Medical Care Equipment Assessment Studies and the quality model proposed by NBR ISO/IEC 9126-1 were followed. Descriptive statistical analysis was used applying Fisher’s exact test, binomial test and Mann-Whitney test. Results: 91.7% of tasks were completed. The infusion pump-2 model was associated (p < 0.001) with operationalization, tasks accomplished with non-conformities, use of a manual calculator (measure effectiveness) and task accomplishment time (measure efficiency). Conclusion: Efficacy and efficiency measures can evidence a better context of usability of IPs and identify interaction failures with the nursing staff to be improved in care practice.Universidade de São Paulo, Escola de Enfermagem2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0080-62342021000100429Revista da Escola de Enfermagem da USP v.55 2021reponame:Revista da Escola de Enfermagem da USP (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/s1980-220x2020001103712info:eu-repo/semantics/openAccessOliveira,Elizandra Cassia da SilvaSilva,Roberto Carlos Lyra daArruda,Gustavo Aires deOliveira,Regina Célia deeng2021-05-06T00:00:00Zoai:scielo:S0080-62342021000100429Revistahttp://www.scielo.br/reeuspPUBhttps://old.scielo.br/oai/scielo-oai.php||nursingscholar@usp.br1980-220X0080-6234opendoar:2021-05-06T00:00Revista da Escola de Enfermagem da USP (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Usability of volumetric infusion pumps in pediatric intensive care
title Usability of volumetric infusion pumps in pediatric intensive care
spellingShingle Usability of volumetric infusion pumps in pediatric intensive care
Oliveira,Elizandra Cassia da Silva
Infusion Pumps
Intensive Care Units, Pediatric
Ergonomics
Pediatric Nursing
Quality of Health Care
Technology Assessment, Biomedical
title_short Usability of volumetric infusion pumps in pediatric intensive care
title_full Usability of volumetric infusion pumps in pediatric intensive care
title_fullStr Usability of volumetric infusion pumps in pediatric intensive care
title_full_unstemmed Usability of volumetric infusion pumps in pediatric intensive care
title_sort Usability of volumetric infusion pumps in pediatric intensive care
author Oliveira,Elizandra Cassia da Silva
author_facet Oliveira,Elizandra Cassia da Silva
Silva,Roberto Carlos Lyra da
Arruda,Gustavo Aires de
Oliveira,Regina Célia de
author_role author
author2 Silva,Roberto Carlos Lyra da
Arruda,Gustavo Aires de
Oliveira,Regina Célia de
author2_role author
author
author
dc.contributor.author.fl_str_mv Oliveira,Elizandra Cassia da Silva
Silva,Roberto Carlos Lyra da
Arruda,Gustavo Aires de
Oliveira,Regina Célia de
dc.subject.por.fl_str_mv Infusion Pumps
Intensive Care Units, Pediatric
Ergonomics
Pediatric Nursing
Quality of Health Care
Technology Assessment, Biomedical
topic Infusion Pumps
Intensive Care Units, Pediatric
Ergonomics
Pediatric Nursing
Quality of Health Care
Technology Assessment, Biomedical
description ABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to September 2018. The Methodological Guideline for Medical Care Equipment Assessment Studies and the quality model proposed by NBR ISO/IEC 9126-1 were followed. Descriptive statistical analysis was used applying Fisher’s exact test, binomial test and Mann-Whitney test. Results: 91.7% of tasks were completed. The infusion pump-2 model was associated (p < 0.001) with operationalization, tasks accomplished with non-conformities, use of a manual calculator (measure effectiveness) and task accomplishment time (measure efficiency). Conclusion: Efficacy and efficiency measures can evidence a better context of usability of IPs and identify interaction failures with the nursing staff to be improved in care practice.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0080-62342021000100429
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0080-62342021000100429
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1980-220x2020001103712
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade de São Paulo, Escola de Enfermagem
publisher.none.fl_str_mv Universidade de São Paulo, Escola de Enfermagem
dc.source.none.fl_str_mv Revista da Escola de Enfermagem da USP v.55 2021
reponame:Revista da Escola de Enfermagem da USP (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Revista da Escola de Enfermagem da USP (Online)
collection Revista da Escola de Enfermagem da USP (Online)
repository.name.fl_str_mv Revista da Escola de Enfermagem da USP (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||nursingscholar@usp.br
_version_ 1748936540984180736