Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista do Hospital das Clínicas |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0041-87812003000200003 |
Resumo: | PURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure. |
id |
USP-57_f0e34a94dc10a3f1e10cc2b53ab451a3 |
---|---|
oai_identifier_str |
oai:scielo:S0041-87812003000200003 |
network_acronym_str |
USP-57 |
network_name_str |
Revista do Hospital das Clínicas |
repository_id_str |
|
spelling |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needlesMediastinal massesTomography, computed axialNeedle biopsyPURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure.Faculdade de Medicina / Universidade de São Paulo - FM/USP2003-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0041-87812003000200003Revista do Hospital das Clínicas v.58 n.2 2003reponame:Revista do Hospital das Clínicasinstname:Universidade de São Paulo (USP)instacron:USP10.1590/S0041-87812003000200003info:eu-repo/semantics/openAccessFarias,André Piovesan deDeheinzelin,DanielYounes,Riad N.Chojniak,Rubenseng2003-06-26T00:00:00Zoai:scielo:S0041-87812003000200003Revistahttp://www.scielo.br/rhcPUBhttps://old.scielo.br/oai/scielo-oai.php||revista.hc@hcnet.usp.br1678-99030041-8781opendoar:2003-06-26T00:00Revista do Hospital das Clínicas - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles |
title |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles |
spellingShingle |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles Farias,André Piovesan de Mediastinal masses Tomography, computed axial Needle biopsy |
title_short |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles |
title_full |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles |
title_fullStr |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles |
title_full_unstemmed |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles |
title_sort |
Computed tomography-guided biopsy of mediastinal lesions: fine versus cutting needles |
author |
Farias,André Piovesan de |
author_facet |
Farias,André Piovesan de Deheinzelin,Daniel Younes,Riad N. Chojniak,Rubens |
author_role |
author |
author2 |
Deheinzelin,Daniel Younes,Riad N. Chojniak,Rubens |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Farias,André Piovesan de Deheinzelin,Daniel Younes,Riad N. Chojniak,Rubens |
dc.subject.por.fl_str_mv |
Mediastinal masses Tomography, computed axial Needle biopsy |
topic |
Mediastinal masses Tomography, computed axial Needle biopsy |
description |
PURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0041-87812003000200003 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0041-87812003000200003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0041-87812003000200003 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade de Medicina / Universidade de São Paulo - FM/USP |
publisher.none.fl_str_mv |
Faculdade de Medicina / Universidade de São Paulo - FM/USP |
dc.source.none.fl_str_mv |
Revista do Hospital das Clínicas v.58 n.2 2003 reponame:Revista do Hospital das Clínicas instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Revista do Hospital das Clínicas |
collection |
Revista do Hospital das Clínicas |
repository.name.fl_str_mv |
Revista do Hospital das Clínicas - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||revista.hc@hcnet.usp.br |
_version_ |
1754820894524440576 |