Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?

Detalhes bibliográficos
Autor(a) principal: Oliveira, Cristiane Santos de
Data de Publicação: 2018
Outros Autores: José, Anderson, Santos, Crislaine Oliveira, Oliveira, Cristiane Helga Yamane de, Carvalho, Thiago Cristiano Oliveira, Silva, Jaksoel Cunha, Selman, Jessyca Pachi Rodrigues, Castro, Rejane Agnelo Silva de, Camargo, Anderson Alves de, Corso, Simone Dal
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Fisioterapia e Pesquisa
Texto Completo: https://www.revistas.usp.br/fpusp/article/view/152869
Resumo: The performances of healthy individuals in an incremental shuttle walking test performed in a hallway (ISWT-H) and on a treadmill (ISWT-T) were compared to assess their physiological responses during aerobic training sessions with the speeds estimated from both tests. This was a cross-sectional study with 55 healthy subjects, who were randomized to perform the ISWT tests with 24 hours between them. Training sessions were held using a treadmill at 75% of the speeds obtained from the ISWT-H and ISWT-T. Measurements included walking distance, oxygen uptake (VO2 ), carbon dioxide (VCO2 ) production, heart rate (HR), and ventilation (VE). There was a significant difference between walking distances (ISWT-T: 823.9±165.2 m and ISWT-H:685.4±141.4 m), but similar physiological responses for VO2 (28.6±6.6 vs. 29.0±7.3 ml-1.kg-1.min-1), VCO2 (1.9±0.7 vs. 1.9±0.5 1), HR (158.3±17.8 vs. 158.6±17.7 bpm), and VE (41.5±10.4 vs. 43.7±12.9 1). The estimated speeds were different for the training sessions (5.5±0.5 km/h and 4.9±0.3 km/h), as well as the VO2 , VCO2 , VE, and HR. It was concluded that in healthy young adults, ISWTs carried out in a hallway and on a treadmill are not interchangeable. Since the ISWT-H was determined to have lower speed, the training intensity based on this test may underestimate a patient’s responses to aerobic training.
id USP-9_c9deb8d7ae86a7cdc59d1fd49182f157
oai_identifier_str oai:revistas.usp.br:article/152869
network_acronym_str USP-9
network_name_str Fisioterapia e Pesquisa
repository_id_str
spelling Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?Shuttle walk teste incremental realizado no corredor e na esteira: eles são intercambiáveis? are they interchangeable?La prueba incremental Shuttle walk realizada en el pasillo y la cinta caminadora: ¿son intercambiables?Teste de EsforçoExercícioCaminhadaConsumo de OxigênioPrueba de EsfuerzoEjercicioCaminataConsumo de OxígenoExercise TestExerciseWalkingOxygen ConsumptionThe performances of healthy individuals in an incremental shuttle walking test performed in a hallway (ISWT-H) and on a treadmill (ISWT-T) were compared to assess their physiological responses during aerobic training sessions with the speeds estimated from both tests. This was a cross-sectional study with 55 healthy subjects, who were randomized to perform the ISWT tests with 24 hours between them. Training sessions were held using a treadmill at 75% of the speeds obtained from the ISWT-H and ISWT-T. Measurements included walking distance, oxygen uptake (VO2 ), carbon dioxide (VCO2 ) production, heart rate (HR), and ventilation (VE). There was a significant difference between walking distances (ISWT-T: 823.9±165.2 m and ISWT-H:685.4±141.4 m), but similar physiological responses for VO2 (28.6±6.6 vs. 29.0±7.3 ml-1.kg-1.min-1), VCO2 (1.9±0.7 vs. 1.9±0.5 1), HR (158.3±17.8 vs. 158.6±17.7 bpm), and VE (41.5±10.4 vs. 43.7±12.9 1). The estimated speeds were different for the training sessions (5.5±0.5 km/h and 4.9±0.3 km/h), as well as the VO2 , VCO2 , VE, and HR. It was concluded that in healthy young adults, ISWTs carried out in a hallway and on a treadmill are not interchangeable. Since the ISWT-H was determined to have lower speed, the training intensity based on this test may underestimate a patient’s responses to aerobic training.Comparou-se o desempenho no shuttle walk teste incremental realizado no corredor (SWTI-C) e na esteira (SWTI-E) em indivíduos saudáveis e comparar as respostas fisiológicas durante as sessões de treinamento aeróbio com as velocidades estimadas em ambos os testes. Trata-se de um estudo transversal com cinquenta e cinco participantes saudáveis. Os participantes foram randomizados para realizar os testes com 24 horas de intervalo. As sessões de treinamento foram realizadas na esteira com 75% da velocidade obtida no SWTI-C e no SWTI-E. As avaliações incluíram a distância da caminhada, consumo de oxigênio (VO2 ), produção de dióxido de carbono (VCO2 ), frequência cardíaca (FC) e ventilação (VE). Houve uma diferença significante entre as distâncias caminhadas (SWTI-E: 823,9 ± 165,2 m e SWTI-C: 685,4 ± 141,4 m), mas respostas fisiológicas semelhantes para o VO2 (28,6 ± 6,6 vs. 29,0 ± 7,3 ml-1.kg-1. min-1), VCO2 (1,9 ± 0,7 vs. 1,9 ± 0,5 1), HR (158,3 ± 17,8 vs. 158,6 ± 17,7 bpm) e VE (41,5 ± 10,4 vs. 43,7 ± 12,9 1). As velocidades estimadas foram diferentes para as sessões de treinamento (5,5 ± 0,5xkm/h e 4,9 ± 0,3 km/h), assim como o VO2 , VCO2 , VE e FC. Concluiu-se que em adultos jovens saudáveis, SWTI realizados no corredor e na esteira não são intercambiáveis. Uma vez que o SWTI-E determinou uma menor velocidade, a intensidade do treinamento baseada neste teste pode subestimar as respostas de um paciente ao treinamento aeróbio.Se trata de una comparación del rendimiento en la prueba incremental shuttle walk llevado a cabo en el pasillo (SWPI-P) y en la cinta caminadora (SWPC) entre individuos sanos, para evaluar las respuestas fisiológicas durante las sesiones de entrenamiento aeróbico con velocidades estimadas en ambas pruebas. Estudio transversal con 55 individuos sanos. A los participantes se les eligieron al azar para realizar las pruebas con intervalo de 24 horas. Se llevaron a cabo sesiones de entrenamiento en la cinta caminadora con el 75 % de la velocidad obtenida en SWPI-P y en SWPC. Se incluyen entre las evaluaciones la distancia de la caminata, el consumo de oxígeno (VO2 ), la producción de dióxido de carbono (VCO2 ), la frecuencia cardiaca (FC) y la ventilación (VE). Hubo una diferencia significativa entre las distancias recorridas (SWPC: 823,9 ± 165,2 m y SWPI-P: 685,4 ± 141,4 m), pero similares a las respuestas fisiológicas del VO2 (28,6 ± 6,6 vs. 29,0 ± 7,3 ml-1.kg-1. min-1), VCO2 (1,9 ± 0,7 vs. ± 1,9 0,5 1), HR (158,3 ± 17,8 vs. 158,6 ± 17,7 bpm) y VE (41,5 ± 10,4 vs. 43,7 ± 12,9 1). Las velocidades estimadas fueron diferentes en las sesiones de entrenamiento (5,5 ± 0,5 km/h y 4,9 ± 0,3 km/h), así como VO2 , VCO2, VE y FC. Se concluyó que, en los adultos jóvenes sanos, la SWPI llevada a cabo en el pasillo y en la cinta caminadora no pueden ser intercambiables. Dado que la SWPC determinó una menor velocidad, la intensidad de entrenamiento de esta prueba puede subestimar las respuestas de un paciente en el entrenamiento aeróbico.Universidade de São Paulo. Faculdade de Medicina2018-11-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/fpusp/article/view/15286910.1590/1809-2950/17008125042018Fisioterapia e Pesquisa; Vol. 25 No. 4 (2018); 395-403Fisioterapia e Pesquisa; Vol. 25 Núm. 4 (2018); 395-403Fisioterapia e Pesquisa; v. 25 n. 4 (2018); 395-4032316-91171809-2950reponame:Fisioterapia e Pesquisainstname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/fpusp/article/view/152869/149367Copyright (c) 2018 Fisioterapia e Pesquisahttps://creativecommons.org/licenses/by-sa/4.0info:eu-repo/semantics/openAccessOliveira, Cristiane Santos deJosé, AndersonSantos, Crislaine OliveiraOliveira, Cristiane Helga Yamane deCarvalho, Thiago Cristiano OliveiraSilva, Jaksoel CunhaSelman, Jessyca Pachi RodriguesCastro, Rejane Agnelo Silva deCamargo, Anderson Alves deCorso, Simone Dal2023-05-26T14:01:16Zoai:revistas.usp.br:article/152869Revistahttp://www.revistas.usp.br/fpuspPUBhttps://www.revistas.usp.br/fpusp/oai||revfisio@usp.br2316-91171809-2950opendoar:2023-05-26T14:01:16Fisioterapia e Pesquisa - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
Shuttle walk teste incremental realizado no corredor e na esteira: eles são intercambiáveis? are they interchangeable?
La prueba incremental Shuttle walk realizada en el pasillo y la cinta caminadora: ¿son intercambiables?
title Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
spellingShingle Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
Oliveira, Cristiane Santos de
Teste de Esforço
Exercício
Caminhada
Consumo de Oxigênio
Prueba de Esfuerzo
Ejercicio
Caminata
Consumo de Oxígeno
Exercise Test
Exercise
Walking
Oxygen Consumption
title_short Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
title_full Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
title_fullStr Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
title_full_unstemmed Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
title_sort Incremental shuttle walk test performed in a hallway and on a treadmill: are they interchangeable?
author Oliveira, Cristiane Santos de
author_facet Oliveira, Cristiane Santos de
José, Anderson
Santos, Crislaine Oliveira
Oliveira, Cristiane Helga Yamane de
Carvalho, Thiago Cristiano Oliveira
Silva, Jaksoel Cunha
Selman, Jessyca Pachi Rodrigues
Castro, Rejane Agnelo Silva de
Camargo, Anderson Alves de
Corso, Simone Dal
author_role author
author2 José, Anderson
Santos, Crislaine Oliveira
Oliveira, Cristiane Helga Yamane de
Carvalho, Thiago Cristiano Oliveira
Silva, Jaksoel Cunha
Selman, Jessyca Pachi Rodrigues
Castro, Rejane Agnelo Silva de
Camargo, Anderson Alves de
Corso, Simone Dal
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Oliveira, Cristiane Santos de
José, Anderson
Santos, Crislaine Oliveira
Oliveira, Cristiane Helga Yamane de
Carvalho, Thiago Cristiano Oliveira
Silva, Jaksoel Cunha
Selman, Jessyca Pachi Rodrigues
Castro, Rejane Agnelo Silva de
Camargo, Anderson Alves de
Corso, Simone Dal
dc.subject.por.fl_str_mv Teste de Esforço
Exercício
Caminhada
Consumo de Oxigênio
Prueba de Esfuerzo
Ejercicio
Caminata
Consumo de Oxígeno
Exercise Test
Exercise
Walking
Oxygen Consumption
topic Teste de Esforço
Exercício
Caminhada
Consumo de Oxigênio
Prueba de Esfuerzo
Ejercicio
Caminata
Consumo de Oxígeno
Exercise Test
Exercise
Walking
Oxygen Consumption
description The performances of healthy individuals in an incremental shuttle walking test performed in a hallway (ISWT-H) and on a treadmill (ISWT-T) were compared to assess their physiological responses during aerobic training sessions with the speeds estimated from both tests. This was a cross-sectional study with 55 healthy subjects, who were randomized to perform the ISWT tests with 24 hours between them. Training sessions were held using a treadmill at 75% of the speeds obtained from the ISWT-H and ISWT-T. Measurements included walking distance, oxygen uptake (VO2 ), carbon dioxide (VCO2 ) production, heart rate (HR), and ventilation (VE). There was a significant difference between walking distances (ISWT-T: 823.9±165.2 m and ISWT-H:685.4±141.4 m), but similar physiological responses for VO2 (28.6±6.6 vs. 29.0±7.3 ml-1.kg-1.min-1), VCO2 (1.9±0.7 vs. 1.9±0.5 1), HR (158.3±17.8 vs. 158.6±17.7 bpm), and VE (41.5±10.4 vs. 43.7±12.9 1). The estimated speeds were different for the training sessions (5.5±0.5 km/h and 4.9±0.3 km/h), as well as the VO2 , VCO2 , VE, and HR. It was concluded that in healthy young adults, ISWTs carried out in a hallway and on a treadmill are not interchangeable. Since the ISWT-H was determined to have lower speed, the training intensity based on this test may underestimate a patient’s responses to aerobic training.
publishDate 2018
dc.date.none.fl_str_mv 2018-11-12
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/fpusp/article/view/152869
10.1590/1809-2950/17008125042018
url https://www.revistas.usp.br/fpusp/article/view/152869
identifier_str_mv 10.1590/1809-2950/17008125042018
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/fpusp/article/view/152869/149367
dc.rights.driver.fl_str_mv Copyright (c) 2018 Fisioterapia e Pesquisa
https://creativecommons.org/licenses/by-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2018 Fisioterapia e Pesquisa
https://creativecommons.org/licenses/by-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Medicina
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Medicina
dc.source.none.fl_str_mv Fisioterapia e Pesquisa; Vol. 25 No. 4 (2018); 395-403
Fisioterapia e Pesquisa; Vol. 25 Núm. 4 (2018); 395-403
Fisioterapia e Pesquisa; v. 25 n. 4 (2018); 395-403
2316-9117
1809-2950
reponame:Fisioterapia e Pesquisa
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Fisioterapia e Pesquisa
collection Fisioterapia e Pesquisa
repository.name.fl_str_mv Fisioterapia e Pesquisa - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||revfisio@usp.br
_version_ 1787713739565301760