High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity

Detalhes bibliográficos
Autor(a) principal: Lima, Lorenna Ellen Alves
Data de Publicação: 2014
Outros Autores: Lima, Ali Sandra de Oliveira, Rocha, Cinara Macedo, Santos, Gabrielly Fontenele dos, Bezerra, Amanda Júlia Ramos, Hazime, Fuad Ahmad, Nunes, Janaina Mayer de Oliveira
Tipo de documento: Artigo
Idioma: eng
por
Título da fonte: Fisioterapia e Pesquisa
Texto Completo: https://www.revistas.usp.br/fpusp/article/view/88386
Resumo: The current study aim was evaluate the analgesic effect of TENS modulation for high (100 Hz) and low (4 Hz) frequency in post-cesarean pain. 34 postpartum women were randomly divided into three treatment groups: 100 Hz (G100), 4 Hz (G4) and Placebo (GP) (appliance off). Pain intensity was assessed by the NRS (Numeric Rating Scale) before, immediately after application of TENS, and every 20 minutes until an hour after the eletroanalgesia session. We used the Friedman test and Mann-Whitney U test (p
id USP-9_e1c92dee13dc3620dc58a9d06f7cc643
oai_identifier_str oai:revistas.usp.br:article/88386
network_acronym_str USP-9
network_name_str Fisioterapia e Pesquisa
repository_id_str
spelling High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity Estimulação elétrica nervosa transcutânea de alta e baixa frequência na intensidade da dor pós-cesárea Estimulación nerviosa eléctrica transcutánea, de alta y baja frecuencia en la intensidad del dolor después de la cesárea The current study aim was evaluate the analgesic effect of TENS modulation for high (100 Hz) and low (4 Hz) frequency in post-cesarean pain. 34 postpartum women were randomly divided into three treatment groups: 100 Hz (G100), 4 Hz (G4) and Placebo (GP) (appliance off). Pain intensity was assessed by the NRS (Numeric Rating Scale) before, immediately after application of TENS, and every 20 minutes until an hour after the eletroanalgesia session. We used the Friedman test and Mann-Whitney U test (p El objetivo del estudio fue evaluar el efecto analgésico de la modulación de la TENS en alta (100 Hz) y baja (4 Hz) frecuencia en el dolor post-cesaría. Participaron 34 puérperas, aleatoriamente divididos en tres grupos de tratamiento: 100 Hz (G100), 4Hz (G4) y Placebo (GP) (aparato en off). La intensidad del dolor fue evaluada por la NRS (Escala de Categoría Numérica) antes, inmediatamente después de la aplicación de la TENS, y a cada 20 minutos, hasta que completase una hora después de la sección de eletroanalgesia. Fueron utilizados las pruebas Friedman y Mann-Whitney U (p O objetivo do estudo foi avaliar o efeito analgésico da modulação da TENS em alta (100 Hz) e baixa (4 Hz) frequência na dor pós-cesárea. Participaram 34 puérperas, aleatoriamente divididas em três grupos de tratamento: 100 Hz (G100), 4 Hz (G4) e Placebo (GP) (aparelho desligado). A intensidade da dor foi avaliada pela NRS (Escala de Categoria Numérica) antes, imediatamente após a aplicação da TENS, e a cada 20 minutos, até que completasse uma hora após a sessão de eletroanalgesia. Foram utilizados os testes de Friedman e Mann-Whitney U (pUniversidade de São Paulo. Faculdade de Medicina2014-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttps://www.revistas.usp.br/fpusp/article/view/8838610.590/1809-2950/65021032014Fisioterapia e Pesquisa; Vol. 21 No. 3 (2014); 243-248Fisioterapia e Pesquisa; Vol. 21 Núm. 3 (2014); 243-248Fisioterapia e Pesquisa; v. 21 n. 3 (2014); 243-2482316-91171809-2950reponame:Fisioterapia e Pesquisainstname:Universidade de São Paulo (USP)instacron:USPengporhttps://www.revistas.usp.br/fpusp/article/view/88386/91262https://www.revistas.usp.br/fpusp/article/view/88386/91263Copyright (c) 2017 Fisioterapia e Pesquisainfo:eu-repo/semantics/openAccessLima, Lorenna Ellen Alves Lima, Ali Sandra de Oliveira Rocha, Cinara Macedo Santos, Gabrielly Fontenele dos Bezerra, Amanda Júlia Ramos Hazime, Fuad Ahmad Nunes, Janaina Mayer de Oliveira 2014-12-02T11:17:56Zoai:revistas.usp.br:article/88386Revistahttp://www.revistas.usp.br/fpuspPUBhttps://www.revistas.usp.br/fpusp/oai||revfisio@usp.br2316-91171809-2950opendoar:2014-12-02T11:17:56Fisioterapia e Pesquisa - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
Estimulação elétrica nervosa transcutânea de alta e baixa frequência na intensidade da dor pós-cesárea
Estimulación nerviosa eléctrica transcutánea, de alta y baja frecuencia en la intensidad del dolor después de la cesárea
title High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
spellingShingle High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
Lima, Lorenna Ellen Alves
title_short High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
title_full High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
title_fullStr High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
title_full_unstemmed High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
title_sort High and low frequency transcutaneous electrical nerve stimulation in post-cesarean pain intensity
author Lima, Lorenna Ellen Alves
author_facet Lima, Lorenna Ellen Alves
Lima, Ali Sandra de Oliveira
Rocha, Cinara Macedo
Santos, Gabrielly Fontenele dos
Bezerra, Amanda Júlia Ramos
Hazime, Fuad Ahmad
Nunes, Janaina Mayer de Oliveira
author_role author
author2 Lima, Ali Sandra de Oliveira
Rocha, Cinara Macedo
Santos, Gabrielly Fontenele dos
Bezerra, Amanda Júlia Ramos
Hazime, Fuad Ahmad
Nunes, Janaina Mayer de Oliveira
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Lima, Lorenna Ellen Alves
Lima, Ali Sandra de Oliveira
Rocha, Cinara Macedo
Santos, Gabrielly Fontenele dos
Bezerra, Amanda Júlia Ramos
Hazime, Fuad Ahmad
Nunes, Janaina Mayer de Oliveira
description The current study aim was evaluate the analgesic effect of TENS modulation for high (100 Hz) and low (4 Hz) frequency in post-cesarean pain. 34 postpartum women were randomly divided into three treatment groups: 100 Hz (G100), 4 Hz (G4) and Placebo (GP) (appliance off). Pain intensity was assessed by the NRS (Numeric Rating Scale) before, immediately after application of TENS, and every 20 minutes until an hour after the eletroanalgesia session. We used the Friedman test and Mann-Whitney U test (p
publishDate 2014
dc.date.none.fl_str_mv 2014-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/fpusp/article/view/88386
10.590/1809-2950/65021032014
url https://www.revistas.usp.br/fpusp/article/view/88386
identifier_str_mv 10.590/1809-2950/65021032014
dc.language.iso.fl_str_mv eng
por
language eng
por
dc.relation.none.fl_str_mv https://www.revistas.usp.br/fpusp/article/view/88386/91262
https://www.revistas.usp.br/fpusp/article/view/88386/91263
dc.rights.driver.fl_str_mv Copyright (c) 2017 Fisioterapia e Pesquisa
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2017 Fisioterapia e Pesquisa
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Medicina
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Medicina
dc.source.none.fl_str_mv Fisioterapia e Pesquisa; Vol. 21 No. 3 (2014); 243-248
Fisioterapia e Pesquisa; Vol. 21 Núm. 3 (2014); 243-248
Fisioterapia e Pesquisa; v. 21 n. 3 (2014); 243-248
2316-9117
1809-2950
reponame:Fisioterapia e Pesquisa
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Fisioterapia e Pesquisa
collection Fisioterapia e Pesquisa
repository.name.fl_str_mv Fisioterapia e Pesquisa - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||revfisio@usp.br
_version_ 1787713737126313984