Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da USP |
Texto Completo: | https://www.teses.usp.br/teses/disponiveis/25/25148/tde-18112021-153330/ |
Resumo: | Purpose: To evaluate the influence of different concentrations of 10-MDP in degree of conversion (%DC) of experimental adhesives (EA) applied with different manipulation protocols (MP). Materials and Methods: EA containing a three-component-photoinitiator system (CQ/DABE/iodonium salt) were prepared and different concentrations of 10-MDP were added A1 = 0%, A2 = 3%, A3 = 6%, A4 = 9%, A5 = 12%, or A6 = 15% by weight. A commercially available adhesive was used as comparison (Ambar, FGM). The adhesives were divided into 4 MP: I) Control (without any manipulation), II) 5 s of evaporation, III) 20 s of evaporation and IV) addition of water to the adhesive. DC was evaluated by FTIR-ATR. The data were analyzed with two-way Anova and Tukey´s HSD ( = 0.05). Results: Significant differences were found between the adhesives (p < 0.0001) and MP (p = 0.000001). An interaction effect (p < 0.0001) was also observed. For adhesives, it was observed that the A5 showed the highest value (89.70% ± 4.21) and the lowest values to EA without MDP (76.35% ± 8.45). Ambar showed intermediate values (83.68% ± 9.46). For MP, the highest DC was observed to Control (88.50% ± 2.72) > 20-s-evaporation (85.13% ± 6.95) 5-s-evaporation (85.18% ± 6.08) addition of water (85.80% ± 10.33). Conclusion: The results suggest that 10- MDP can enhance the %DC of the threecomponent- photoinitiator system EAs evaluated. |
id |
USP_43354a21620de68180fa86c599922db2 |
---|---|
oai_identifier_str |
oai:teses.usp.br:tde-18112021-153330 |
network_acronym_str |
USP |
network_name_str |
Biblioteca Digital de Teses e Dissertações da USP |
repository_id_str |
2721 |
spelling |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocolsInfluência da concentração de 10-metacriloiloxidecil dihidrogeniofosfato (MDP) no grau de conversão de adesivos experimentais aplicados com diferentes protocolos de manipulação10-MDP10-metacriloiloxidecil dihidrogêniofosfato (MDP)AdesivoAdhesiveÁguaDegree of conversionEspectroscopia Transformada de Fourier Infravermelho (FTIR)Evaporação de solventesFourier transform infrared spectrophotometer (FTIR)Grau de conversãoIodonium saltSolvent evaporationWaterPurpose: To evaluate the influence of different concentrations of 10-MDP in degree of conversion (%DC) of experimental adhesives (EA) applied with different manipulation protocols (MP). Materials and Methods: EA containing a three-component-photoinitiator system (CQ/DABE/iodonium salt) were prepared and different concentrations of 10-MDP were added A1 = 0%, A2 = 3%, A3 = 6%, A4 = 9%, A5 = 12%, or A6 = 15% by weight. A commercially available adhesive was used as comparison (Ambar, FGM). The adhesives were divided into 4 MP: I) Control (without any manipulation), II) 5 s of evaporation, III) 20 s of evaporation and IV) addition of water to the adhesive. DC was evaluated by FTIR-ATR. The data were analyzed with two-way Anova and Tukey´s HSD ( = 0.05). Results: Significant differences were found between the adhesives (p < 0.0001) and MP (p = 0.000001). An interaction effect (p < 0.0001) was also observed. For adhesives, it was observed that the A5 showed the highest value (89.70% ± 4.21) and the lowest values to EA without MDP (76.35% ± 8.45). Ambar showed intermediate values (83.68% ± 9.46). For MP, the highest DC was observed to Control (88.50% ± 2.72) > 20-s-evaporation (85.13% ± 6.95) 5-s-evaporation (85.18% ± 6.08) addition of water (85.80% ± 10.33). Conclusion: The results suggest that 10- MDP can enhance the %DC of the threecomponent- photoinitiator system EAs evaluated.Propósito: Avaliar a influência de diferentes concentrações do 10-MDP no grau de conversão (%GC) de adesivos experimentais (AE) em diferentes protocolos de manipulação (PM). Material e Métodos: Os AE contêm um sistema iniciador triplo (CQ/DABE/sal diodônio) e diferentes concentrações de 10-MDP A1 = 0%, A2 = 3%, A3 = 6%, A4 = 9%, A5 = 12% ou A6 = 15% em peso foram adicionadas. Um adesivo comercialmente disponível foi utilizado para comparação (Ambar, FGM). Os adesivos foram divididos em 4 PM: I) Controle (sem manipulação), II) 5 s de evaporação, III) 20 s de evaporação e IV) adição de água. O GC foi avliado com o FTIR-ATR. Os dados foram analisados com Anova a dois critérios e Tukey ( = 0,05). Resultados: Diferenças significativas foram encontradas entre os adesivos (p < 0.0001) e PM (p = 0.000001). Também foi encontrado um efeito de interação (p < 0.0001). Para os adesivos, foi observado que o A5 obteve o maior resultado (89.70% ± 4.21) e o com menor valor foi o AE sem MDP (76.35% ± 8.45). O Ambar obteve valores intermediários (83.68% ± 9.46). Para o PM, o maior valor foi para: Controle (88.50% ± 2.72) > 20-s-evaporação (85.13% ± 6.95) 5-s-evaporação (85.18% ± 6.08) adição de água (85.80% ± 10.33). Conclusão: Os resultados obtidos sugerem que o 10- MDP pode aumentar a %GC dos AE com o sistema iniciador triplo.Biblioteca Digitais de Teses e Dissertações da USPFuruse, Adilson YoshioNarimatsu, Mayara Hana2016-05-06info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://www.teses.usp.br/teses/disponiveis/25/25148/tde-18112021-153330/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesseng2021-12-09T20:30:41Zoai:teses.usp.br:tde-18112021-153330Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212021-12-09T20:30:41Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols Influência da concentração de 10-metacriloiloxidecil dihidrogeniofosfato (MDP) no grau de conversão de adesivos experimentais aplicados com diferentes protocolos de manipulação |
title |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols |
spellingShingle |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols Narimatsu, Mayara Hana 10-MDP 10-metacriloiloxidecil dihidrogêniofosfato (MDP) Adesivo Adhesive Água Degree of conversion Espectroscopia Transformada de Fourier Infravermelho (FTIR) Evaporação de solventes Fourier transform infrared spectrophotometer (FTIR) Grau de conversão Iodonium salt Solvent evaporation Water |
title_short |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols |
title_full |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols |
title_fullStr |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols |
title_full_unstemmed |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols |
title_sort |
Influence of the concentration of 10-metacryloxydecyl dihydrogen phosphate (10-MDP) on the degree of conversion of experimental adhesives applied with different manipulation protocols |
author |
Narimatsu, Mayara Hana |
author_facet |
Narimatsu, Mayara Hana |
author_role |
author |
dc.contributor.none.fl_str_mv |
Furuse, Adilson Yoshio |
dc.contributor.author.fl_str_mv |
Narimatsu, Mayara Hana |
dc.subject.por.fl_str_mv |
10-MDP 10-metacriloiloxidecil dihidrogêniofosfato (MDP) Adesivo Adhesive Água Degree of conversion Espectroscopia Transformada de Fourier Infravermelho (FTIR) Evaporação de solventes Fourier transform infrared spectrophotometer (FTIR) Grau de conversão Iodonium salt Solvent evaporation Water |
topic |
10-MDP 10-metacriloiloxidecil dihidrogêniofosfato (MDP) Adesivo Adhesive Água Degree of conversion Espectroscopia Transformada de Fourier Infravermelho (FTIR) Evaporação de solventes Fourier transform infrared spectrophotometer (FTIR) Grau de conversão Iodonium salt Solvent evaporation Water |
description |
Purpose: To evaluate the influence of different concentrations of 10-MDP in degree of conversion (%DC) of experimental adhesives (EA) applied with different manipulation protocols (MP). Materials and Methods: EA containing a three-component-photoinitiator system (CQ/DABE/iodonium salt) were prepared and different concentrations of 10-MDP were added A1 = 0%, A2 = 3%, A3 = 6%, A4 = 9%, A5 = 12%, or A6 = 15% by weight. A commercially available adhesive was used as comparison (Ambar, FGM). The adhesives were divided into 4 MP: I) Control (without any manipulation), II) 5 s of evaporation, III) 20 s of evaporation and IV) addition of water to the adhesive. DC was evaluated by FTIR-ATR. The data were analyzed with two-way Anova and Tukey´s HSD ( = 0.05). Results: Significant differences were found between the adhesives (p < 0.0001) and MP (p = 0.000001). An interaction effect (p < 0.0001) was also observed. For adhesives, it was observed that the A5 showed the highest value (89.70% ± 4.21) and the lowest values to EA without MDP (76.35% ± 8.45). Ambar showed intermediate values (83.68% ± 9.46). For MP, the highest DC was observed to Control (88.50% ± 2.72) > 20-s-evaporation (85.13% ± 6.95) 5-s-evaporation (85.18% ± 6.08) addition of water (85.80% ± 10.33). Conclusion: The results suggest that 10- MDP can enhance the %DC of the threecomponent- photoinitiator system EAs evaluated. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-05-06 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.teses.usp.br/teses/disponiveis/25/25148/tde-18112021-153330/ |
url |
https://www.teses.usp.br/teses/disponiveis/25/25148/tde-18112021-153330/ |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
|
dc.rights.driver.fl_str_mv |
Liberar o conteúdo para acesso público. info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Liberar o conteúdo para acesso público. |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.none.fl_str_mv |
|
dc.publisher.none.fl_str_mv |
Biblioteca Digitais de Teses e Dissertações da USP |
publisher.none.fl_str_mv |
Biblioteca Digitais de Teses e Dissertações da USP |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da USP instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Biblioteca Digital de Teses e Dissertações da USP |
collection |
Biblioteca Digital de Teses e Dissertações da USP |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br |
_version_ |
1809090845393027072 |