Shear wave elastography with two-dimensional ultrasound transducer.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da USP |
Texto Completo: | http://www.teses.usp.br/teses/disponiveis/3/3154/tde-01102018-142217/ |
Resumo: | Chronic liver diseases are the eighth leading cause of death in Brazil and a major public health problem in the world. Liver biopsy is the best available reference standard for evaluating and classifying stages of liver diseases, but it presents limitations and complications that are common in invasive methods. In recent years, elasticity imaging methods have been the focus of intense research activity with the ability to measure mechanical properties of soft tissues in a non-invasive way. Shear wave elastography is one of the most promising methods because it enables to quantitatively assess tissue elasticity. However, the current depth range of shear wave elastography impedes its application in obese patients, which have a great risk of developing liver disease. The aim of this study is to investigate the use of shear wave elastography in deeper tissues using a two-dimensional ultrasound transducer array. An efficient transducer array arrangement was simulated, fabricated and characterized. The results show that the proposed transducer configuration presents enhanced transmitting capabilities for generating tissue displacement in deeper tissues. In addition, numerical simulations were performed in order to track the tissue deformation and reconstruct its elastic properties. |
id |
USP_71e6e32d1f17177dc010de1f295956d9 |
---|---|
oai_identifier_str |
oai:teses.usp.br:tde-01102018-142217 |
network_acronym_str |
USP |
network_name_str |
Biblioteca Digital de Teses e Dissertações da USP |
repository_id_str |
2721 |
spelling |
Shear wave elastography with two-dimensional ultrasound transducer.Elastografia por onda de cisalhamento com transdutor de ultrassom bidimensional.Acoustic radiation forceArray transducerDiagnóstico por imagemElastografia por onda de cisalhamentoForça de radiação acústicaShear wave elastographyTransdutor de ultrassomTransdutor matricialUltrasound transducerUltrassonografiaChronic liver diseases are the eighth leading cause of death in Brazil and a major public health problem in the world. Liver biopsy is the best available reference standard for evaluating and classifying stages of liver diseases, but it presents limitations and complications that are common in invasive methods. In recent years, elasticity imaging methods have been the focus of intense research activity with the ability to measure mechanical properties of soft tissues in a non-invasive way. Shear wave elastography is one of the most promising methods because it enables to quantitatively assess tissue elasticity. However, the current depth range of shear wave elastography impedes its application in obese patients, which have a great risk of developing liver disease. The aim of this study is to investigate the use of shear wave elastography in deeper tissues using a two-dimensional ultrasound transducer array. An efficient transducer array arrangement was simulated, fabricated and characterized. The results show that the proposed transducer configuration presents enhanced transmitting capabilities for generating tissue displacement in deeper tissues. In addition, numerical simulations were performed in order to track the tissue deformation and reconstruct its elastic properties.Doenças crônicas do fígado são a oitava causa de morte no Brasil e um dos principais problemas de saúde pública do mundo. A biópsia do fígado é o melhor padrão de referência disponível para avaliação e classificação dos estágios das doenças hepáticas, mas apresenta limitações e complicações que são comuns nos métodos invasivos. Nos últimos anos, métodos de imagem por elasticidade têm sido o foco de intensa atividade de pesquisa, pois têm a capacidade de medir propriedades mecânicas dos tecidos moles de maneira não invasiva. A elastografia por ondas de cisalhamento é um dos métodos mais promissores, pois permite avaliar quantitativamente a elasticidade do tecido. No entanto, a atual faixa de profundidade da elastografia por ondas de cisalhamento impede sua aplicação em pacientes obesos, que apresentam grande risco de desenvolver doença hepática. O objetivo deste estudo é investigar o uso da elastografia por onda de cisalhamento em tecidos mais profundos usando um transdutor de ultrassom bidimensional. Uma configuração eficiente de transdutores matriciais foi simulada, fabricada e caracterizada. Os resultados mostram que o transdutor proposto possui capacidade de transmissão melhorada para gerar deslocamento em tecidos profundos. Além disso, simulações numéricas foram realizadas para monitorar a deformação do tecido e reconstruir suas propriedades elásticas.Biblioteca Digitais de Teses e Dissertações da USPFuruie, Sérgio ShiguemiSantos, Djalma Simões dos2018-07-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://www.teses.usp.br/teses/disponiveis/3/3154/tde-01102018-142217/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesseng2018-11-01T16:25:01Zoai:teses.usp.br:tde-01102018-142217Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212018-11-01T16:25:01Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Shear wave elastography with two-dimensional ultrasound transducer. Elastografia por onda de cisalhamento com transdutor de ultrassom bidimensional. |
title |
Shear wave elastography with two-dimensional ultrasound transducer. |
spellingShingle |
Shear wave elastography with two-dimensional ultrasound transducer. Santos, Djalma Simões dos Acoustic radiation force Array transducer Diagnóstico por imagem Elastografia por onda de cisalhamento Força de radiação acústica Shear wave elastography Transdutor de ultrassom Transdutor matricial Ultrasound transducer Ultrassonografia |
title_short |
Shear wave elastography with two-dimensional ultrasound transducer. |
title_full |
Shear wave elastography with two-dimensional ultrasound transducer. |
title_fullStr |
Shear wave elastography with two-dimensional ultrasound transducer. |
title_full_unstemmed |
Shear wave elastography with two-dimensional ultrasound transducer. |
title_sort |
Shear wave elastography with two-dimensional ultrasound transducer. |
author |
Santos, Djalma Simões dos |
author_facet |
Santos, Djalma Simões dos |
author_role |
author |
dc.contributor.none.fl_str_mv |
Furuie, Sérgio Shiguemi |
dc.contributor.author.fl_str_mv |
Santos, Djalma Simões dos |
dc.subject.por.fl_str_mv |
Acoustic radiation force Array transducer Diagnóstico por imagem Elastografia por onda de cisalhamento Força de radiação acústica Shear wave elastography Transdutor de ultrassom Transdutor matricial Ultrasound transducer Ultrassonografia |
topic |
Acoustic radiation force Array transducer Diagnóstico por imagem Elastografia por onda de cisalhamento Força de radiação acústica Shear wave elastography Transdutor de ultrassom Transdutor matricial Ultrasound transducer Ultrassonografia |
description |
Chronic liver diseases are the eighth leading cause of death in Brazil and a major public health problem in the world. Liver biopsy is the best available reference standard for evaluating and classifying stages of liver diseases, but it presents limitations and complications that are common in invasive methods. In recent years, elasticity imaging methods have been the focus of intense research activity with the ability to measure mechanical properties of soft tissues in a non-invasive way. Shear wave elastography is one of the most promising methods because it enables to quantitatively assess tissue elasticity. However, the current depth range of shear wave elastography impedes its application in obese patients, which have a great risk of developing liver disease. The aim of this study is to investigate the use of shear wave elastography in deeper tissues using a two-dimensional ultrasound transducer array. An efficient transducer array arrangement was simulated, fabricated and characterized. The results show that the proposed transducer configuration presents enhanced transmitting capabilities for generating tissue displacement in deeper tissues. In addition, numerical simulations were performed in order to track the tissue deformation and reconstruct its elastic properties. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-07-30 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.teses.usp.br/teses/disponiveis/3/3154/tde-01102018-142217/ |
url |
http://www.teses.usp.br/teses/disponiveis/3/3154/tde-01102018-142217/ |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
|
dc.rights.driver.fl_str_mv |
Liberar o conteúdo para acesso público. info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Liberar o conteúdo para acesso público. |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.none.fl_str_mv |
|
dc.publisher.none.fl_str_mv |
Biblioteca Digitais de Teses e Dissertações da USP |
publisher.none.fl_str_mv |
Biblioteca Digitais de Teses e Dissertações da USP |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da USP instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Biblioteca Digital de Teses e Dissertações da USP |
collection |
Biblioteca Digital de Teses e Dissertações da USP |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br |
_version_ |
1815256589112705024 |