Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente

Detalhes bibliográficos
Autor(a) principal: Fumincelli, Laís
Data de Publicação: 2016
Tipo de documento: Tese
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da USP
Texto Completo: http://www.teses.usp.br/teses/disponiveis/22/22132/tde-13022017-201727/
Resumo: Estudo multicêntrico, que teve como objetivo geral compreender as implicações do uso do cateterismo urinário intermitente na qualidade de vida (QV) de pacientes e de cuidadores de pacientes com bexiga neurogênica. Como objetivos específicos, identificar as evidências científicas sobre a QV desses pacientes e/ou cuidadores; caracterizar os pacientes; mensurar a sua QV; analisar as relações entre a QV dos pacientes e os aspectos sociodemográficos, clínicos e do uso do cateter urinário; identificar se realidades geopolíticas e socioculturais distintas interferem na QV dos pacientes; caracterizar os cuidadores e mensurar a sua QV; e analisar as relações entre a QV e os aspectos sociodemográficos e do cuidado. Seguidos os preceitos éticos, o estudo foi realizado com pacientes maiores de 18 anos, com diagnóstico de bexiga urinária neurogênica, usuários do cateterismo urinário intermitente, em um ambulatório de um centro de reabilitação de um Hospital Universitário no interior do estado de São Paulo, no Brasil, e em dois centros de reabilitação, na região central de Coimbra, em Portugal. Para a coleta de dados, foi utilizado um questionário sociodemográfico e clínico, e um questionário de QV, já traduzido e validado no Brasil e em Portugal, chamado World Health Organization Quality Life-bref (WHOQOL-bref). Os cuidadores foram entrevistados no Brasil. Entre os cuidadores, foram incluídos os cuidadores que se corresponsabilizam com o procedimento. Foi utilizado um questionário de caracterização sociodemográfica e dos cuidados e WHOQOL-bref. Os dados foram analisados por estatística descritiva e uso de testes estatísticos com o uso do programa Statistical Package for Social Science (SPSS), versão 22 (Windows). Na amostra de pacientes, brasileiros (n=170) e portugueses (n=52), a maioria era de pessoas solteiras, com ensino fundamental e aposentadas. A lesão medular foi a principal causa do uso do cateter urinário nos dois países. O cateterismo urinário intermitente era realizado pela maioria dos pacientes em mais de quatro vezes ao dia e em um período superior a dez anos. Em relação à QV, os pacientes brasileiros apresentaram escores mais elevados de QV no domínio psicológico e menos elevados no domínio físico. Os pacientes portugueses apresentaram escores mais elevados no domínio psicológico e menos elevados no domínio ambiente. A realização do autocateterismo urinário intermitente para os dois países também foi estatisticamente significativa. Quanto aos cuidadores entrevistados, a maioria (n=74) era do gênero feminino, pessoas casadas e com ensino fundamental. Na análise da QV, os cuidadores apresentaram elevados escores no domínio ambiente e menor escore no domínio psicológico. A QV dos pacientes usuários de cateterismo urinário intermitente pode ser determinada pela melhora dos sintomas urinários, assim como independência, autoconfiança, relações sociais, acesso à atividades laborais e inserção social. Os cuidadores apresentam fragilidades em certos domínios de vida. Cabe aos profissionais de saúde a compreensão desse fenômeno para atuar junto a essa população
id USP_b2cd5d1164278392d226e9b53d7f281b
oai_identifier_str oai:teses.usp.br:tde-13022017-201727
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitenteQuality of life of patients and caregivers of patients with neurogenic bladder in use of intermittent urinary catheterizationCaregiversCateterismo uretral intermitenteCuidadoresEnfermagemIntermittent urethral catheterizationNursingPacientePatientQualidade de vidaQuality of lifeEstudo multicêntrico, que teve como objetivo geral compreender as implicações do uso do cateterismo urinário intermitente na qualidade de vida (QV) de pacientes e de cuidadores de pacientes com bexiga neurogênica. Como objetivos específicos, identificar as evidências científicas sobre a QV desses pacientes e/ou cuidadores; caracterizar os pacientes; mensurar a sua QV; analisar as relações entre a QV dos pacientes e os aspectos sociodemográficos, clínicos e do uso do cateter urinário; identificar se realidades geopolíticas e socioculturais distintas interferem na QV dos pacientes; caracterizar os cuidadores e mensurar a sua QV; e analisar as relações entre a QV e os aspectos sociodemográficos e do cuidado. Seguidos os preceitos éticos, o estudo foi realizado com pacientes maiores de 18 anos, com diagnóstico de bexiga urinária neurogênica, usuários do cateterismo urinário intermitente, em um ambulatório de um centro de reabilitação de um Hospital Universitário no interior do estado de São Paulo, no Brasil, e em dois centros de reabilitação, na região central de Coimbra, em Portugal. Para a coleta de dados, foi utilizado um questionário sociodemográfico e clínico, e um questionário de QV, já traduzido e validado no Brasil e em Portugal, chamado World Health Organization Quality Life-bref (WHOQOL-bref). Os cuidadores foram entrevistados no Brasil. Entre os cuidadores, foram incluídos os cuidadores que se corresponsabilizam com o procedimento. Foi utilizado um questionário de caracterização sociodemográfica e dos cuidados e WHOQOL-bref. Os dados foram analisados por estatística descritiva e uso de testes estatísticos com o uso do programa Statistical Package for Social Science (SPSS), versão 22 (Windows). Na amostra de pacientes, brasileiros (n=170) e portugueses (n=52), a maioria era de pessoas solteiras, com ensino fundamental e aposentadas. A lesão medular foi a principal causa do uso do cateter urinário nos dois países. O cateterismo urinário intermitente era realizado pela maioria dos pacientes em mais de quatro vezes ao dia e em um período superior a dez anos. Em relação à QV, os pacientes brasileiros apresentaram escores mais elevados de QV no domínio psicológico e menos elevados no domínio físico. Os pacientes portugueses apresentaram escores mais elevados no domínio psicológico e menos elevados no domínio ambiente. A realização do autocateterismo urinário intermitente para os dois países também foi estatisticamente significativa. Quanto aos cuidadores entrevistados, a maioria (n=74) era do gênero feminino, pessoas casadas e com ensino fundamental. Na análise da QV, os cuidadores apresentaram elevados escores no domínio ambiente e menor escore no domínio psicológico. A QV dos pacientes usuários de cateterismo urinário intermitente pode ser determinada pela melhora dos sintomas urinários, assim como independência, autoconfiança, relações sociais, acesso à atividades laborais e inserção social. Os cuidadores apresentam fragilidades em certos domínios de vida. Cabe aos profissionais de saúde a compreensão desse fenômeno para atuar junto a essa populaçãoMulticenter study, which aimed to understand the implications of the use of intermittent urinary catheterization on the quality of life (QoL) of patients and caregivers of patients with neurogenic urinary bladder. The specific objectives, identify the scientific evidence on the QoL of patients and/or caregivers; characterize the patients; measure their QoL; analyze the relations between QoL of patients and the sociodemographic, clinical and use of urinary catheter aspects; identify whether distinct geopolitical and socio-cultural realities can interfere on the QoL of patients; characterize caregivers and measure their QoL; and analyze the relations between QoL and sociodemographic and care aspects. Followed the ethical precepts, the study was conducted with patients older than 18 years, diagnosed with neurogenic urinary bladder, intermittent urinary catheterization users, at outpatient clinic of a rehabilitation center in the University Hospital in the State of São Paulo, Brazil, and two rehabilitation centers in central region of Coimbra, Portugal. To collect data, a sociodemographic and clinical questionnaire was used, and a QoL questionnaire, translated and validated in Brazil and Portugal, World Health Organization Quality Life-BREF (WHOQOL-bref). The caregivers were interviewed in Brazil. Among the caregivers, were included those were responsible by the procedure. A questionnaire regarding to sociodemographic and care and WHOQOL-bref were used. The data were assessed by means of descriptive statistics and statistical tests using the Statistical Package for Social Sciences (SPSS) version 22 (Windows). Of the Brazilian (n = 170) and Portuguese (n = 52) patients, most were single people, elementary school and retired. Spinal cord injury was the main cause of urinary catheter use in both countries. Most patients performed intermittent urinary catheterization over four times a day and for a period of ten years. Regarding QoL, Brazilian patients had higher scores of QoL in the psychological domain and less in the physical domain. The Portuguese patients had higher scores in the psychological domain and less environment domain. The realization of intermittent urinary catheterization for the two countries was also statistically significant. As for the caregivers interviewed, the majority (n = 74) were female, married people and elementary school. In the analysis of QoL, caregivers showed high scores in the environment domain and lowest score in the psychological domain. QoL of users of intermittent urinary catheterization can be determined by improvement of urinary symptoms, as well as independence, self-confidence, social relations, access to employment and social inclusion activities. The caregivers have fragilities in certain areas of their life. The health professionals should understand this phenomenon and working with this populationBiblioteca Digitais de Teses e Dissertações da USPMazzo, AlessandraFumincelli, Laís2016-11-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfhttp://www.teses.usp.br/teses/disponiveis/22/22132/tde-13022017-201727/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesspor2018-07-17T16:34:08Zoai:teses.usp.br:tde-13022017-201727Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212018-07-17T16:34:08Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
Quality of life of patients and caregivers of patients with neurogenic bladder in use of intermittent urinary catheterization
title Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
spellingShingle Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
Fumincelli, Laís
Caregivers
Cateterismo uretral intermitente
Cuidadores
Enfermagem
Intermittent urethral catheterization
Nursing
Paciente
Patient
Qualidade de vida
Quality of life
title_short Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
title_full Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
title_fullStr Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
title_full_unstemmed Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
title_sort Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente
author Fumincelli, Laís
author_facet Fumincelli, Laís
author_role author
dc.contributor.none.fl_str_mv Mazzo, Alessandra
dc.contributor.author.fl_str_mv Fumincelli, Laís
dc.subject.por.fl_str_mv Caregivers
Cateterismo uretral intermitente
Cuidadores
Enfermagem
Intermittent urethral catheterization
Nursing
Paciente
Patient
Qualidade de vida
Quality of life
topic Caregivers
Cateterismo uretral intermitente
Cuidadores
Enfermagem
Intermittent urethral catheterization
Nursing
Paciente
Patient
Qualidade de vida
Quality of life
description Estudo multicêntrico, que teve como objetivo geral compreender as implicações do uso do cateterismo urinário intermitente na qualidade de vida (QV) de pacientes e de cuidadores de pacientes com bexiga neurogênica. Como objetivos específicos, identificar as evidências científicas sobre a QV desses pacientes e/ou cuidadores; caracterizar os pacientes; mensurar a sua QV; analisar as relações entre a QV dos pacientes e os aspectos sociodemográficos, clínicos e do uso do cateter urinário; identificar se realidades geopolíticas e socioculturais distintas interferem na QV dos pacientes; caracterizar os cuidadores e mensurar a sua QV; e analisar as relações entre a QV e os aspectos sociodemográficos e do cuidado. Seguidos os preceitos éticos, o estudo foi realizado com pacientes maiores de 18 anos, com diagnóstico de bexiga urinária neurogênica, usuários do cateterismo urinário intermitente, em um ambulatório de um centro de reabilitação de um Hospital Universitário no interior do estado de São Paulo, no Brasil, e em dois centros de reabilitação, na região central de Coimbra, em Portugal. Para a coleta de dados, foi utilizado um questionário sociodemográfico e clínico, e um questionário de QV, já traduzido e validado no Brasil e em Portugal, chamado World Health Organization Quality Life-bref (WHOQOL-bref). Os cuidadores foram entrevistados no Brasil. Entre os cuidadores, foram incluídos os cuidadores que se corresponsabilizam com o procedimento. Foi utilizado um questionário de caracterização sociodemográfica e dos cuidados e WHOQOL-bref. Os dados foram analisados por estatística descritiva e uso de testes estatísticos com o uso do programa Statistical Package for Social Science (SPSS), versão 22 (Windows). Na amostra de pacientes, brasileiros (n=170) e portugueses (n=52), a maioria era de pessoas solteiras, com ensino fundamental e aposentadas. A lesão medular foi a principal causa do uso do cateter urinário nos dois países. O cateterismo urinário intermitente era realizado pela maioria dos pacientes em mais de quatro vezes ao dia e em um período superior a dez anos. Em relação à QV, os pacientes brasileiros apresentaram escores mais elevados de QV no domínio psicológico e menos elevados no domínio físico. Os pacientes portugueses apresentaram escores mais elevados no domínio psicológico e menos elevados no domínio ambiente. A realização do autocateterismo urinário intermitente para os dois países também foi estatisticamente significativa. Quanto aos cuidadores entrevistados, a maioria (n=74) era do gênero feminino, pessoas casadas e com ensino fundamental. Na análise da QV, os cuidadores apresentaram elevados escores no domínio ambiente e menor escore no domínio psicológico. A QV dos pacientes usuários de cateterismo urinário intermitente pode ser determinada pela melhora dos sintomas urinários, assim como independência, autoconfiança, relações sociais, acesso à atividades laborais e inserção social. Os cuidadores apresentam fragilidades em certos domínios de vida. Cabe aos profissionais de saúde a compreensão desse fenômeno para atuar junto a essa população
publishDate 2016
dc.date.none.fl_str_mv 2016-11-04
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.teses.usp.br/teses/disponiveis/22/22132/tde-13022017-201727/
url http://www.teses.usp.br/teses/disponiveis/22/22132/tde-13022017-201727/
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv
dc.rights.driver.fl_str_mv Liberar o conteúdo para acesso público.
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Liberar o conteúdo para acesso público.
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv
dc.publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
dc.source.none.fl_str_mv
reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1809090670066925568