Resumo: Reactive power support by photovoltaic farms has been under discussion in several countries. This kind of operation has been proposed because the photovoltaic farm converter is an expensive asset that is often used well below its power rating. This paper proposes a methodology for estimating the reactive power support capability and the associated technical cost of operating a photovoltaic installation as a STATCOM at nighttime. The technical cost is related to the need to buy active power from the grid to compensate for power losses. A precise estimation of this cost is of interest for both photovoltaic farm owners and grid operators to be able to evaluate the economic feasibility of this kind of operation. In order to illustrate the proposed methodology, a 1.5 MWp photovoltaic farm is considered. By evaluating the losses of each component (converter, tie reactor, filter and transformer), a reactive power support capability map integrating the technical cost for each point of operation is obtained. The analysis outlines key points to operate a PV farm as a STATCOM at nighttime: the system must include a blocking diode, the capability map is asymmetric, an operation with variable DC-link voltage is desirable and can lead to savings of up to 8.9 % in comparison with operation at fixed nominal DC-link voltage.
id USP_d7cc3d6f86a15ea4a17637273954b062
oai_identifier_str oai:teses.usp.br:tde-23102017-104035
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling Technical cost of operating a PV installation as a STATCOM during nightime.Avaliação do custo técnico da operação de uma fazenda solar fotovoltaica como um STATCOM no período da noite.Conversores elétricosEnergia solarPhotovoltaic solar farmsPower lossesSistemas fotovoltaicosStatcomReactive power support by photovoltaic farms has been under discussion in several countries. This kind of operation has been proposed because the photovoltaic farm converter is an expensive asset that is often used well below its power rating. This paper proposes a methodology for estimating the reactive power support capability and the associated technical cost of operating a photovoltaic installation as a STATCOM at nighttime. The technical cost is related to the need to buy active power from the grid to compensate for power losses. A precise estimation of this cost is of interest for both photovoltaic farm owners and grid operators to be able to evaluate the economic feasibility of this kind of operation. In order to illustrate the proposed methodology, a 1.5 MWp photovoltaic farm is considered. By evaluating the losses of each component (converter, tie reactor, filter and transformer), a reactive power support capability map integrating the technical cost for each point of operation is obtained. The analysis outlines key points to operate a PV farm as a STATCOM at nighttime: the system must include a blocking diode, the capability map is asymmetric, an operation with variable DC-link voltage is desirable and can lead to savings of up to 8.9 % in comparison with operation at fixed nominal DC-link voltage.O suporte de potência reativa por fazendas solares fotovoltaicas está sob discussão em diversos países. Este tipo de operação foi proposta pois o conversor das fazendas solares é um equipamento de custo elevado que é usualmente utilizado abaixo de sua potência nominal. Este trabalho propõe uma metodologia para estimar a capabilidade de suporte de reativos e o custo técnico associado na operação de uma fazenda solar fotovoltaica como um STATCOM durante o período da noite. O custo técnico desta operação está associado à necessidade da compra de potência ativa da rede elétrica para suprir as perdas de energia para compensar as perdas nos equipamentos. Uma estimativa precisa deste custo técnico é de interesse tanto dos empreendedores que possuem fazendas fotovoltaicas como dos operadores da rede elétrica para que se avalie a viabilidade econômica deste tipo de operação. Para ilustrar a metodologia proposta, uma fazenda solar fotovoltaica de 1.5 MWp é considerada. Através da avaliação das perdas em cada componente (conversor, reator, filtro e transformador), um mapa de capabilidade de suporte de potência reativa é obtido integrando os custos técnicos para cada ponto de operação. A análise realizada neste trabalho destaca os pontos chave para a operação noturna de uma fazenda solar como STATCOM: o sistema deve incluir um diodo de bloqueio, o mapa de capabilidade é assimétrico, a operação com tensão do circuito CC é desejável e resulta em economia de energia de 8.9 % em comparação com operação com a operação em tensão nominal fixa do circuito CC.Biblioteca Digitais de Teses e Dissertações da USPMonaro, Renato MachadoSalles, Maurício Barbosa de CamargoLourenço, Luís Felipe Normandia2017-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://www.teses.usp.br/teses/disponiveis/3/3143/tde-23102017-104035/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesseng2018-07-17T16:38:18Zoai:teses.usp.br:tde-23102017-104035Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212018-07-17T16:38:18Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Technical cost of operating a PV installation as a STATCOM during nightime.
Avaliação do custo técnico da operação de uma fazenda solar fotovoltaica como um STATCOM no período da noite.
title Technical cost of operating a PV installation as a STATCOM during nightime.
spellingShingle Technical cost of operating a PV installation as a STATCOM during nightime.
Lourenço, Luís Felipe Normandia
Conversores elétricos
Energia solar
Photovoltaic solar farms
Power losses
Sistemas fotovoltaicos
Statcom
title_short Technical cost of operating a PV installation as a STATCOM during nightime.
title_full Technical cost of operating a PV installation as a STATCOM during nightime.
title_fullStr Technical cost of operating a PV installation as a STATCOM during nightime.
title_full_unstemmed Technical cost of operating a PV installation as a STATCOM during nightime.
title_sort Technical cost of operating a PV installation as a STATCOM during nightime.
author Lourenço, Luís Felipe Normandia
author_facet Lourenço, Luís Felipe Normandia
author_role author
dc.contributor.none.fl_str_mv Monaro, Renato Machado
Salles, Maurício Barbosa de Camargo
dc.contributor.author.fl_str_mv Lourenço, Luís Felipe Normandia
dc.subject.por.fl_str_mv Conversores elétricos
Energia solar
Photovoltaic solar farms
Power losses
Sistemas fotovoltaicos
Statcom
topic Conversores elétricos
Energia solar
Photovoltaic solar farms
Power losses
Sistemas fotovoltaicos
Statcom
description Reactive power support by photovoltaic farms has been under discussion in several countries. This kind of operation has been proposed because the photovoltaic farm converter is an expensive asset that is often used well below its power rating. This paper proposes a methodology for estimating the reactive power support capability and the associated technical cost of operating a photovoltaic installation as a STATCOM at nighttime. The technical cost is related to the need to buy active power from the grid to compensate for power losses. A precise estimation of this cost is of interest for both photovoltaic farm owners and grid operators to be able to evaluate the economic feasibility of this kind of operation. In order to illustrate the proposed methodology, a 1.5 MWp photovoltaic farm is considered. By evaluating the losses of each component (converter, tie reactor, filter and transformer), a reactive power support capability map integrating the technical cost for each point of operation is obtained. The analysis outlines key points to operate a PV farm as a STATCOM at nighttime: the system must include a blocking diode, the capability map is asymmetric, an operation with variable DC-link voltage is desirable and can lead to savings of up to 8.9 % in comparison with operation at fixed nominal DC-link voltage.
publishDate 2017
dc.date.none.fl_str_mv 2017-08-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.teses.usp.br/teses/disponiveis/3/3143/tde-23102017-104035/
url http://www.teses.usp.br/teses/disponiveis/3/3143/tde-23102017-104035/
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv
dc.rights.driver.fl_str_mv Liberar o conteúdo para acesso público.
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Liberar o conteúdo para acesso público.
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv
dc.publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
dc.source.none.fl_str_mv
reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1815257375568822272