Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas

Detalhes bibliográficos
Autor(a) principal: Gabriela Gonçalez Piai
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da USP
Texto Completo: https://doi.org/10.11606/D.25.2020.tde-22102021-131403
Resumo: O objetivo do presente estudo foi avaliar o comportamento mecânico do Reciproc Blue R25 (VDW, Munich, Alemanha) frente a diferentes anatomias e temperaturas. Quarenta e oito molares inferiores foram selecionados, escaneados via microCT e padronizados. Os canais mesiais foram classificados seguindo o proposto por Ahmed et al 2017. Foram utilizadas as siglas MI (molar inferior) e Rm (raiz mesial) para todos os dentes variando apenas os expoentes referentes as quantidades de embocaduras, canais e forames. Foram utilizados os dentes classificados como MIRm1-1-1, MIRm2-2- 1-1, MIRm1-1-2-1-1, MIRm2-2-2. Estes foram divididos em 2 grupos: temperatura ambiente (20ºC) e corporal (37ºC). Utilizou-se 16 instrumentos Reciproc Blue 25.08 e 2ml de hipoclorito de sódio 1% a cada inserção do instrumento. Os dentes foram novamente escaneados e verificou-se a porcentagem (%) de: aumento de volume, superfície não tocada e remoção de dentina nas paredes mesiais e distal. Além da análise do transporte e capacidade de centralização. Foi realizado o teste torsinal nos instrumentos e estes analisados em MEV. O teste Shapiro-Wilk foi utilizado para verificação da normalidade entre as amostras. O teste Kruskal-Wallis seguido do teste Dunn foram aplicados para a análise da qualidade do preparo nas diferentes anatomias; e o teste t foi aplicado para as análises da qualidade do preparo e resistência torsional nas diferentes temperaturas de instrumentação. O nível de significância adotado foi de 5%. Tendo como variável a anatomia, o menor aumento de volume e a maior quantidade de superfície não tocada ocorreu no MIRm1-1-1. A maior porcentagem de remoção de dentina em todos os grupos foi para distal, no terço cervical. Não houve diferença estatística com relação ao transporte e centralização. Com relação a temperatura, não houve diferença estatística no aumento do volume e superfície não tocada. O grupo da temperatura ambiente teve a maior quantidade de remoção de dentina para distal no terço cervical, assim como o maior transporte nesta região. Já o grupo da temperatura corporal apresentou maior centralização do preparo no terço cervical. A deflexão angular foi maior na temperatura ambiente. Conclui-se que a anatomia e a temperatura influenciam na qualidade do preparo, além da temperatura interferir na deflexão angular.
id USP_de67b4d7608ac308e7463929b15bb7f6
oai_identifier_str oai:teses.usp.br:tde-22102021-131403
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas The aim of the present study was to evaluate the mechanical behavior of the Reciproc Blue R25 (VDW, Munich, Germany) against different anatomies and temperatures. Forty-eight lower molars were selected, scanned by microCT and standardized. The mesial canals were classified according to what was proposed by Ahmed et al 2017. The acronyms MI (lower molar) and Rm (mesial root) were used for all teeth, varying only the exponents referring to the amounts of orifices, canals and foramina. Teeth classified as MIRm1-1-1, MIRm2-2-1-1, MIRm1-1-2-1-1, MIRm2-2-2 were used. These were divided into 2 groups: room temperature (20ºC) and body temperature (37ºC). Sixteen Reciproc Blue 25.08 instruments and 2ml of 1% sodium hypochlorite were used for each instrument insertion. The teeth were again scanned and the percentage (%) of: increased volume, untouched surface and dentin removal on the mesial and distal walls was verified. In addition to the analysis of transport and centralization capacity. The torsinal test was performed on the instruments and they were analyzed using SEM. The Shapiro-Wilk test was used to verify normality between samples. The Kruskal-Wallis test followed by the Dunn test were applied to analyze the quality of the preparation in the different anatomies; and the t-test was applied to analyze the preparation quality and torsional strength at different instrumentation temperatures. The level of significance adopted was 5%. With anatomy as a variable, the smallest volume increase and the largest amount of untouched surface occurred in MIRm1-1-1. The highest percentage of dentin removal in all groups was for distal, in the cervical third. There was no statistical difference regarding transport and centralization. Regarding temperature, there was no statistical difference in volume increase and untouched surface. The room temperature group had the greatest amount of dentin removal to distal in the cervical third, as well as the greatest transport in this region. The body temperature group, on the other hand, showed greater centralization of the preparation in the cervical third. Angular deflection was greater at room temperature. It is concluded that anatomy and temperature influence the quality of the preparation, in addition to the temperature interfering with angular deflection. 2020-06-25Rodrigo Ricci VivanBruno Cavalini CavenagoMarco Antonio Hungaro DuarteRenato Miotto PaloGabriela Gonçalez PiaiUniversidade de São PauloCiências Odontológicas AplicadasUSPBR Anatomia Anatomy Body temperature Fadiga Fatigue Temperatura corporal O objetivo do presente estudo foi avaliar o comportamento mecânico do Reciproc Blue R25 (VDW, Munich, Alemanha) frente a diferentes anatomias e temperaturas. Quarenta e oito molares inferiores foram selecionados, escaneados via microCT e padronizados. Os canais mesiais foram classificados seguindo o proposto por Ahmed et al 2017. Foram utilizadas as siglas MI (molar inferior) e Rm (raiz mesial) para todos os dentes variando apenas os expoentes referentes as quantidades de embocaduras, canais e forames. Foram utilizados os dentes classificados como MIRm1-1-1, MIRm2-2- 1-1, MIRm1-1-2-1-1, MIRm2-2-2. Estes foram divididos em 2 grupos: temperatura ambiente (20ºC) e corporal (37ºC). Utilizou-se 16 instrumentos Reciproc Blue 25.08 e 2ml de hipoclorito de sódio 1% a cada inserção do instrumento. Os dentes foram novamente escaneados e verificou-se a porcentagem (%) de: aumento de volume, superfície não tocada e remoção de dentina nas paredes mesiais e distal. Além da análise do transporte e capacidade de centralização. Foi realizado o teste torsinal nos instrumentos e estes analisados em MEV. O teste Shapiro-Wilk foi utilizado para verificação da normalidade entre as amostras. O teste Kruskal-Wallis seguido do teste Dunn foram aplicados para a análise da qualidade do preparo nas diferentes anatomias; e o teste t foi aplicado para as análises da qualidade do preparo e resistência torsional nas diferentes temperaturas de instrumentação. O nível de significância adotado foi de 5%. Tendo como variável a anatomia, o menor aumento de volume e a maior quantidade de superfície não tocada ocorreu no MIRm1-1-1. A maior porcentagem de remoção de dentina em todos os grupos foi para distal, no terço cervical. Não houve diferença estatística com relação ao transporte e centralização. Com relação a temperatura, não houve diferença estatística no aumento do volume e superfície não tocada. O grupo da temperatura ambiente teve a maior quantidade de remoção de dentina para distal no terço cervical, assim como o maior transporte nesta região. Já o grupo da temperatura corporal apresentou maior centralização do preparo no terço cervical. A deflexão angular foi maior na temperatura ambiente. Conclui-se que a anatomia e a temperatura influenciam na qualidade do preparo, além da temperatura interferir na deflexão angular. The aim of the present study was to evaluate the mechanical behavior of the Reciproc Blue R25 (VDW, Munich, Germany) against different anatomies and temperatures. Forty-eight lower molars were selected, scanned by microCT and standardized. The mesial canals were classified according to what was proposed by Ahmed et al 2017. The acronyms MI (lower molar) and Rm (mesial root) were used for all teeth, varying only the exponents referring to the amounts of orifices, canals and foramina. Teeth classified as MIRm1-1-1, MIRm2-2-1-1, MIRm1-1-2-1-1, MIRm2-2-2 were used. These were divided into 2 groups: room temperature (20ºC) and body temperature (37ºC). Sixteen Reciproc Blue 25.08 instruments and 2ml of 1% sodium hypochlorite were used for each instrument insertion. The teeth were again scanned and the percentage (%) of: increased volume, untouched surface and dentin removal on the mesial and distal walls was verified. In addition to the analysis of transport and centralization capacity. The torsinal test was performed on the instruments and they were analyzed using SEM. The Shapiro-Wilk test was used to verify normality between samples. The Kruskal-Wallis test followed by the Dunn test were applied to analyze the quality of the preparation in the different anatomies; and the t-test was applied to analyze the preparation quality and torsional strength at different instrumentation temperatures. The level of significance adopted was 5%. With anatomy as a variable, the smallest volume increase and the largest amount of untouched surface occurred in MIRm1-1-1. The highest percentage of dentin removal in all groups was for distal, in the cervical third. There was no statistical difference regarding transport and centralization. Regarding temperature, there was no statistical difference in volume increase and untouched surface. The room temperature group had the greatest amount of dentin removal to distal in the cervical third, as well as the greatest transport in this region. The body temperature group, on the other hand, showed greater centralization of the preparation in the cervical third. Angular deflection was greater at room temperature. It is concluded that anatomy and temperature influence the quality of the preparation, in addition to the temperature interfering with angular deflection. https://doi.org/10.11606/D.25.2020.tde-22102021-131403info:eu-repo/semantics/openAccessporreponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USP2023-12-21T19:55:06Zoai:teses.usp.br:tde-22102021-131403Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212023-12-22T13:09:46.662533Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.pt.fl_str_mv Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
dc.title.alternative.en.fl_str_mv The aim of the present study was to evaluate the mechanical behavior of the Reciproc Blue R25 (VDW, Munich, Germany) against different anatomies and temperatures. Forty-eight lower molars were selected, scanned by microCT and standardized. The mesial canals were classified according to what was proposed by Ahmed et al 2017. The acronyms MI (lower molar) and Rm (mesial root) were used for all teeth, varying only the exponents referring to the amounts of orifices, canals and foramina. Teeth classified as MIRm1-1-1, MIRm2-2-1-1, MIRm1-1-2-1-1, MIRm2-2-2 were used. These were divided into 2 groups: room temperature (20ºC) and body temperature (37ºC). Sixteen Reciproc Blue 25.08 instruments and 2ml of 1% sodium hypochlorite were used for each instrument insertion. The teeth were again scanned and the percentage (%) of: increased volume, untouched surface and dentin removal on the mesial and distal walls was verified. In addition to the analysis of transport and centralization capacity. The torsinal test was performed on the instruments and they were analyzed using SEM. The Shapiro-Wilk test was used to verify normality between samples. The Kruskal-Wallis test followed by the Dunn test were applied to analyze the quality of the preparation in the different anatomies; and the t-test was applied to analyze the preparation quality and torsional strength at different instrumentation temperatures. The level of significance adopted was 5%. With anatomy as a variable, the smallest volume increase and the largest amount of untouched surface occurred in MIRm1-1-1. The highest percentage of dentin removal in all groups was for distal, in the cervical third. There was no statistical difference regarding transport and centralization. Regarding temperature, there was no statistical difference in volume increase and untouched surface. The room temperature group had the greatest amount of dentin removal to distal in the cervical third, as well as the greatest transport in this region. The body temperature group, on the other hand, showed greater centralization of the preparation in the cervical third. Angular deflection was greater at room temperature. It is concluded that anatomy and temperature influence the quality of the preparation, in addition to the temperature interfering with angular deflection.
title Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
spellingShingle Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
Gabriela Gonçalez Piai
title_short Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
title_full Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
title_fullStr Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
title_full_unstemmed Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
title_sort Avaliação do comportamento mecânico do Reciproc Blue frente a diferentes anatomias e temperaturas
author Gabriela Gonçalez Piai
author_facet Gabriela Gonçalez Piai
author_role author
dc.contributor.advisor1.fl_str_mv Rodrigo Ricci Vivan
dc.contributor.referee1.fl_str_mv Bruno Cavalini Cavenago
dc.contributor.referee2.fl_str_mv Marco Antonio Hungaro Duarte
dc.contributor.referee3.fl_str_mv Renato Miotto Palo
dc.contributor.author.fl_str_mv Gabriela Gonçalez Piai
contributor_str_mv Rodrigo Ricci Vivan
Bruno Cavalini Cavenago
Marco Antonio Hungaro Duarte
Renato Miotto Palo
description O objetivo do presente estudo foi avaliar o comportamento mecânico do Reciproc Blue R25 (VDW, Munich, Alemanha) frente a diferentes anatomias e temperaturas. Quarenta e oito molares inferiores foram selecionados, escaneados via microCT e padronizados. Os canais mesiais foram classificados seguindo o proposto por Ahmed et al 2017. Foram utilizadas as siglas MI (molar inferior) e Rm (raiz mesial) para todos os dentes variando apenas os expoentes referentes as quantidades de embocaduras, canais e forames. Foram utilizados os dentes classificados como MIRm1-1-1, MIRm2-2- 1-1, MIRm1-1-2-1-1, MIRm2-2-2. Estes foram divididos em 2 grupos: temperatura ambiente (20ºC) e corporal (37ºC). Utilizou-se 16 instrumentos Reciproc Blue 25.08 e 2ml de hipoclorito de sódio 1% a cada inserção do instrumento. Os dentes foram novamente escaneados e verificou-se a porcentagem (%) de: aumento de volume, superfície não tocada e remoção de dentina nas paredes mesiais e distal. Além da análise do transporte e capacidade de centralização. Foi realizado o teste torsinal nos instrumentos e estes analisados em MEV. O teste Shapiro-Wilk foi utilizado para verificação da normalidade entre as amostras. O teste Kruskal-Wallis seguido do teste Dunn foram aplicados para a análise da qualidade do preparo nas diferentes anatomias; e o teste t foi aplicado para as análises da qualidade do preparo e resistência torsional nas diferentes temperaturas de instrumentação. O nível de significância adotado foi de 5%. Tendo como variável a anatomia, o menor aumento de volume e a maior quantidade de superfície não tocada ocorreu no MIRm1-1-1. A maior porcentagem de remoção de dentina em todos os grupos foi para distal, no terço cervical. Não houve diferença estatística com relação ao transporte e centralização. Com relação a temperatura, não houve diferença estatística no aumento do volume e superfície não tocada. O grupo da temperatura ambiente teve a maior quantidade de remoção de dentina para distal no terço cervical, assim como o maior transporte nesta região. Já o grupo da temperatura corporal apresentou maior centralização do preparo no terço cervical. A deflexão angular foi maior na temperatura ambiente. Conclui-se que a anatomia e a temperatura influenciam na qualidade do preparo, além da temperatura interferir na deflexão angular.
publishDate 2020
dc.date.issued.fl_str_mv 2020-06-25
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.11606/D.25.2020.tde-22102021-131403
url https://doi.org/10.11606/D.25.2020.tde-22102021-131403
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade de São Paulo
dc.publisher.program.fl_str_mv Ciências Odontológicas Aplicadas
dc.publisher.initials.fl_str_mv USP
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade de São Paulo
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1794502981464358912