Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo

Detalhes bibliográficos
Autor(a) principal: Pinto, Letícia Sgarbi
Data de Publicação: 2018
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da USP
Texto Completo: http://www.teses.usp.br/teses/disponiveis/58/58135/tde-29082018-100327/
Resumo: O objetivo do presente trabalho foi quantificar, in vitro e in vivo, a endotoxina bacteriana (LPS) aderida a ligaduras ortodônticas elastoméricas estéticas de poliuretano e de silicone, empregando o teste Limulus Amebocyte Lysate (LAL). Para o estudo in vitro foram utilizadas quatro tipos de ligaduras elastoméricas estéticas: Sani-Ties (poliuretano) e Sili-Ties (silicone), da GAC, e Mini Single Case Ligature Stick (poliuretano) e Synergy&reg; Low-friction ligatures (silicone), da Rock Mountain, sendo 5 contaminadas com solução de endotoxina (controle positivo) e 5 não-contaminadas (controle negativo). Réplicas feitas de fio de amarrilho torcido e de aço inox fundido, de mesmo tamanho e formato das ligaduras elastoméricas, contaminadas ou não com endotoxina, foram usadas como controle. A quantificação de endotoxina foi realizada por meio do teste LAL (Kit QCL-1000&trade;), sendo os resultados expressos em unidades de endotoxina (UE/mL). No estudo in vivo, 20 pacientes de ambos os gêneros, com faixa etária entre 15 e 30 anos, que iniciaram tratamento com aparelho ortodôntico fixo na Faculdade de Odontologia de Ribeirão Preto - Universidade de São Paulo receberam, randomicamente, em quadrantes alternados, os mesmos quatro tipos de ligaduras elastoméricas utilizadas no estudo in vitro, sendo uma ligadura de cada marca inserida nos caninos superiores e inferiores (13, 23, 33 e 43), aleatoriamente. Vinte e um dias após, as ligaduras foram removidas e processadas para quantificação da endotoxina bacteriana, utilizando também o Kit QCL-1000&trade;. Todos os dados obtidos foram submetidos à análise estatística apropriada de acordo com a distribuição dos dados, por meio dos testes de Kruskal-Wallis e pós-teste de Dunn (estudo in vitro) e ANOVA de medidas repetidas e pós-teste de Tukey (estudo in vivo). Todas as análises foram efetuadas por meio do programa Graph Pad Prism 4.0, com nível de significância de 5%. De acordo com os resultados obtidos, observou-se que a endotoxina bacteriana aderiu-se a todos os materiais testados. No estudo in vitro, o grupo GAC silicone foi o que apresentou menor mediana de contaminação (1,15 UE/mL), com relação aos outros grupos (p<0,0001), os quais não apresentaram diferença estatisticamente significante quando comparados entre si (p>0,05). No estudo in vivo, de maneira semelhante ao observado no estudo in vitro, o grupo GAC silicone foi o que apresentou menor média de contaminação (0,577±0,017 UE/mL), com diferença estatisticamente significante (p<0,001) em comparação aos demais grupos. Pôde-se concluir, que a endotoxina bacteriana apresentou afinidade pelas ligaduras elastoméricas estéticas à base de silicone e poliuretano testadas. As ligaduras de silicone da marca GAC foram as que apresentaram menor quantidade de endotoxina aderida às suas superfícies
id USP_df0520e3be22a4457952e091f857551c
oai_identifier_str oai:teses.usp.br:tde-29082018-100327
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivoOrthodontic elastomeric aesthetic ligatures: quantification of bacterial endotoxin in vitro and in vivoElastômerosElastomersEndotoxinasEndotoxinsLigaduraLigationLimulus testLipopolissacarídeosLipopolysaccharidesOrthodonticsOrtodontiaTeste do LimulusO objetivo do presente trabalho foi quantificar, in vitro e in vivo, a endotoxina bacteriana (LPS) aderida a ligaduras ortodônticas elastoméricas estéticas de poliuretano e de silicone, empregando o teste Limulus Amebocyte Lysate (LAL). Para o estudo in vitro foram utilizadas quatro tipos de ligaduras elastoméricas estéticas: Sani-Ties (poliuretano) e Sili-Ties (silicone), da GAC, e Mini Single Case Ligature Stick (poliuretano) e Synergy&reg; Low-friction ligatures (silicone), da Rock Mountain, sendo 5 contaminadas com solução de endotoxina (controle positivo) e 5 não-contaminadas (controle negativo). Réplicas feitas de fio de amarrilho torcido e de aço inox fundido, de mesmo tamanho e formato das ligaduras elastoméricas, contaminadas ou não com endotoxina, foram usadas como controle. A quantificação de endotoxina foi realizada por meio do teste LAL (Kit QCL-1000&trade;), sendo os resultados expressos em unidades de endotoxina (UE/mL). No estudo in vivo, 20 pacientes de ambos os gêneros, com faixa etária entre 15 e 30 anos, que iniciaram tratamento com aparelho ortodôntico fixo na Faculdade de Odontologia de Ribeirão Preto - Universidade de São Paulo receberam, randomicamente, em quadrantes alternados, os mesmos quatro tipos de ligaduras elastoméricas utilizadas no estudo in vitro, sendo uma ligadura de cada marca inserida nos caninos superiores e inferiores (13, 23, 33 e 43), aleatoriamente. Vinte e um dias após, as ligaduras foram removidas e processadas para quantificação da endotoxina bacteriana, utilizando também o Kit QCL-1000&trade;. Todos os dados obtidos foram submetidos à análise estatística apropriada de acordo com a distribuição dos dados, por meio dos testes de Kruskal-Wallis e pós-teste de Dunn (estudo in vitro) e ANOVA de medidas repetidas e pós-teste de Tukey (estudo in vivo). Todas as análises foram efetuadas por meio do programa Graph Pad Prism 4.0, com nível de significância de 5%. De acordo com os resultados obtidos, observou-se que a endotoxina bacteriana aderiu-se a todos os materiais testados. No estudo in vitro, o grupo GAC silicone foi o que apresentou menor mediana de contaminação (1,15 UE/mL), com relação aos outros grupos (p<0,0001), os quais não apresentaram diferença estatisticamente significante quando comparados entre si (p>0,05). No estudo in vivo, de maneira semelhante ao observado no estudo in vitro, o grupo GAC silicone foi o que apresentou menor média de contaminação (0,577±0,017 UE/mL), com diferença estatisticamente significante (p<0,001) em comparação aos demais grupos. Pôde-se concluir, que a endotoxina bacteriana apresentou afinidade pelas ligaduras elastoméricas estéticas à base de silicone e poliuretano testadas. As ligaduras de silicone da marca GAC foram as que apresentaram menor quantidade de endotoxina aderida às suas superfíciesThe objective of this study was to quantify, in vitro and in vivo, bacterial endotoxin (LPS) attached to esthetic elastomeric orthodontic ligatures made of polyurethane and silicone using the Limulus Amebocyte Lysate test (LAL). For the in vitro study, were used four types of aesthetic elastomeric ligatures: Sani-Ties (polyurethane) and Sili-Ties (silicone) - GAC, and Mini Single Case Ligature Stick (polyurethane) and Synergy&reg; Low-friction ligatures (silicone) - Rock Mountain; 5 of each were contaminated with endotoxin solution (positive control) and 5 non-contaminated (negative control). Replicas made of twisted wire ligatures and of cast stainless steel, of the same size and shape than the elastomeric ligatures, contaminated or not with endotoxin, were used as control. Endotoxin quantification was performed using the LAL test (QCL-1000&trade; kit), the results being expressed in EU/mL. In the in vivo study, 20 patients of both genders, with ages ranging from 15 to 30 years old, who started treatment with a fixed orthodontic appliance at the School of Dentistry of Ribeirão Preto - University of São Paulo, received randomly the same four types of elastomeric ligatures used in the in vitro study, being a ligature of each brand inserted in the upper and lower canines (UR3, UL3, LR3, LL3), randomly. Twenty-one days later, ligatures were removed and processed for quantification of bacterial endotoxin, using the same test as the in vitro study. All data were submitted to appropriate statistical analysis according to the data distribution, using KruskalWallis tests and Dunn post-test (in vitro study) and ANOVA of repeated measurements and Tukey\'s post-test (in vivo study). All analyzes were performed using the Graph Pad Prism 4.0 program, with a significance level of 5%. According to the results obtained, it was observed that the bacterial endotoxin attached to all materials tested. In the in vitro study, the GAC silicone group had the lowest median contamination (1.15 EU/mL), in relation to the other groups (p<0.0001), which did not present a statistically significant difference when compared to each other (p>0.05). In the in vivo study, similar to that observed in the in vitro study, the GAC silicone group had the lowest mean contamination (0.577 ± 0.017 EU/mL), with a statistically significant difference (p< 0.001) compared to the others groups. It could be concluded that bacterial endotoxin exhibited affinity for the tested silicone and polyurethane aesthetic elastomeric ligatures. The silicone ligatures of GAC brand were the ones that presented less amount of endotoxin attached to their surfacesBiblioteca Digitais de Teses e Dissertações da USPNelson Filho, PauloPinto, Letícia Sgarbi2018-05-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://www.teses.usp.br/teses/disponiveis/58/58135/tde-29082018-100327/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesspor2019-07-25T23:17:40Zoai:teses.usp.br:tde-29082018-100327Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212019-07-25T23:17:40Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
Orthodontic elastomeric aesthetic ligatures: quantification of bacterial endotoxin in vitro and in vivo
title Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
spellingShingle Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
Pinto, Letícia Sgarbi
Elastômeros
Elastomers
Endotoxinas
Endotoxins
Ligadura
Ligation
Limulus test
Lipopolissacarídeos
Lipopolysaccharides
Orthodontics
Ortodontia
Teste do Limulus
title_short Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
title_full Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
title_fullStr Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
title_full_unstemmed Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
title_sort Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo
author Pinto, Letícia Sgarbi
author_facet Pinto, Letícia Sgarbi
author_role author
dc.contributor.none.fl_str_mv Nelson Filho, Paulo
dc.contributor.author.fl_str_mv Pinto, Letícia Sgarbi
dc.subject.por.fl_str_mv Elastômeros
Elastomers
Endotoxinas
Endotoxins
Ligadura
Ligation
Limulus test
Lipopolissacarídeos
Lipopolysaccharides
Orthodontics
Ortodontia
Teste do Limulus
topic Elastômeros
Elastomers
Endotoxinas
Endotoxins
Ligadura
Ligation
Limulus test
Lipopolissacarídeos
Lipopolysaccharides
Orthodontics
Ortodontia
Teste do Limulus
description O objetivo do presente trabalho foi quantificar, in vitro e in vivo, a endotoxina bacteriana (LPS) aderida a ligaduras ortodônticas elastoméricas estéticas de poliuretano e de silicone, empregando o teste Limulus Amebocyte Lysate (LAL). Para o estudo in vitro foram utilizadas quatro tipos de ligaduras elastoméricas estéticas: Sani-Ties (poliuretano) e Sili-Ties (silicone), da GAC, e Mini Single Case Ligature Stick (poliuretano) e Synergy&reg; Low-friction ligatures (silicone), da Rock Mountain, sendo 5 contaminadas com solução de endotoxina (controle positivo) e 5 não-contaminadas (controle negativo). Réplicas feitas de fio de amarrilho torcido e de aço inox fundido, de mesmo tamanho e formato das ligaduras elastoméricas, contaminadas ou não com endotoxina, foram usadas como controle. A quantificação de endotoxina foi realizada por meio do teste LAL (Kit QCL-1000&trade;), sendo os resultados expressos em unidades de endotoxina (UE/mL). No estudo in vivo, 20 pacientes de ambos os gêneros, com faixa etária entre 15 e 30 anos, que iniciaram tratamento com aparelho ortodôntico fixo na Faculdade de Odontologia de Ribeirão Preto - Universidade de São Paulo receberam, randomicamente, em quadrantes alternados, os mesmos quatro tipos de ligaduras elastoméricas utilizadas no estudo in vitro, sendo uma ligadura de cada marca inserida nos caninos superiores e inferiores (13, 23, 33 e 43), aleatoriamente. Vinte e um dias após, as ligaduras foram removidas e processadas para quantificação da endotoxina bacteriana, utilizando também o Kit QCL-1000&trade;. Todos os dados obtidos foram submetidos à análise estatística apropriada de acordo com a distribuição dos dados, por meio dos testes de Kruskal-Wallis e pós-teste de Dunn (estudo in vitro) e ANOVA de medidas repetidas e pós-teste de Tukey (estudo in vivo). Todas as análises foram efetuadas por meio do programa Graph Pad Prism 4.0, com nível de significância de 5%. De acordo com os resultados obtidos, observou-se que a endotoxina bacteriana aderiu-se a todos os materiais testados. No estudo in vitro, o grupo GAC silicone foi o que apresentou menor mediana de contaminação (1,15 UE/mL), com relação aos outros grupos (p<0,0001), os quais não apresentaram diferença estatisticamente significante quando comparados entre si (p>0,05). No estudo in vivo, de maneira semelhante ao observado no estudo in vitro, o grupo GAC silicone foi o que apresentou menor média de contaminação (0,577±0,017 UE/mL), com diferença estatisticamente significante (p<0,001) em comparação aos demais grupos. Pôde-se concluir, que a endotoxina bacteriana apresentou afinidade pelas ligaduras elastoméricas estéticas à base de silicone e poliuretano testadas. As ligaduras de silicone da marca GAC foram as que apresentaram menor quantidade de endotoxina aderida às suas superfícies
publishDate 2018
dc.date.none.fl_str_mv 2018-05-11
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.teses.usp.br/teses/disponiveis/58/58135/tde-29082018-100327/
url http://www.teses.usp.br/teses/disponiveis/58/58135/tde-29082018-100327/
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv
dc.rights.driver.fl_str_mv Liberar o conteúdo para acesso público.
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Liberar o conteúdo para acesso público.
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv
dc.publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
dc.source.none.fl_str_mv
reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br