IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400

Detalhes bibliográficos
Autor(a) principal: PIMENTA-MARTINS, Maria Gardenny Ribeiro; Universidade Estadual do Ceará
Data de Publicação: 2014
Outros Autores: FURTADO, Roselayne Ferro, DUTRA, Rosa Fireman, HENEINE, Luiz Guilherme Dias, DIAS, Ricardo Souza, BORGES, Maria de Fátima, ALVES, Carlucio Roberto
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista da Universidade Vale do Rio Verde (Online)
Texto Completo: http://periodicos.unincor.br/index.php/revistaunincor/article/view/1400
Resumo: Staphylococcal enterotoxin is one of the more aggressive enterotoxins produced by Staphylococcus aureus strains and it is a common cause of food poisoning. Analytical methods that are sensitive, low cost and easy to use are needed to evaluate the food quality. This work describes the development of a label free immunosensor based on screen-printed AuNPs/carbon and the characterization of its analytical response for staphylococcal enterotoxin B (SEB) detection. The biosensor was constructed from self-assembled monolayer of thiols and protein A for the oriented immobilization of the polyclonal antibodies against SEB. As electrons mediator, potassium ferrocyanide was used. The electrochemical detection was direct with the parameters following: -0.2 to 0.6 V with the pulse amplitude of 0.075 V and the pulse width of 75 ms. The immunosensor showed detection and quantification limits of 0.4 µg mL-1 and 1.6 µg mL-1,respectively. The immunosensor showed quite satisfactory performance in contaminated and non-contaminated cheese samples.
id UVRV-2_23f17669c71fb4971820ff1690c3931c
oai_identifier_str oai:ojs.teste.unincor.br:article/1400
network_acronym_str UVRV-2
network_name_str Revista da Universidade Vale do Rio Verde (Online)
repository_id_str
spelling IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400Ciência e Tecnologia de Alimentos; Química, Física, Físico-Química e Bioquí mica dos Alim. e das Mat.-Primas AlimentaresScreen-printed carbon (SPCE); Staphylococcal enterotoxin B; Biosensor; Food safety; Analysis.BiossensorStaphylococcal enterotoxin is one of the more aggressive enterotoxins produced by Staphylococcus aureus strains and it is a common cause of food poisoning. Analytical methods that are sensitive, low cost and easy to use are needed to evaluate the food quality. This work describes the development of a label free immunosensor based on screen-printed AuNPs/carbon and the characterization of its analytical response for staphylococcal enterotoxin B (SEB) detection. The biosensor was constructed from self-assembled monolayer of thiols and protein A for the oriented immobilization of the polyclonal antibodies against SEB. As electrons mediator, potassium ferrocyanide was used. The electrochemical detection was direct with the parameters following: -0.2 to 0.6 V with the pulse amplitude of 0.075 V and the pulse width of 75 ms. The immunosensor showed detection and quantification limits of 0.4 µg mL-1 and 1.6 µg mL-1,respectively. The immunosensor showed quite satisfactory performance in contaminated and non-contaminated cheese samples.ABECCNPq, FUNCAP, CAPES, Embrapa, FINEPPIMENTA-MARTINS, Maria Gardenny Ribeiro; Universidade Estadual do CearáFURTADO, Roselayne FerroDUTRA, Rosa FiremanHENEINE, Luiz Guilherme DiasDIAS, Ricardo SouzaBORGES, Maria de FátimaALVES, Carlucio Roberto2014-07-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://periodicos.unincor.br/index.php/revistaunincor/article/view/140010.5892/ruvrd.v12i1.1400Revista da Universidade Vale do Rio Verde; v. 12, n. 1 (2014); 895-9042236-53621517-027610.5892/ruvrd.v12i1reponame:Revista da Universidade Vale do Rio Verde (Online)instname:Universidade Vale do Rio Verde (UNINCOR)instacron:UVRVporhttp://periodicos.unincor.br/index.php/revistaunincor/article/view/1400/pdf_17210.5892/ruvrd.v12i1.1400.g1248Direitos autorais 2021 Revista da Universidade Vale do Rio Verdeinfo:eu-repo/semantics/openAccess2016-04-28T14:23:29Zoai:ojs.teste.unincor.br:article/1400Revistahttp://periodicos.unincor.br/index.php/revistaunincor/indexPRIhttp://periodicos.unincor.br/index.php/revistaunincor/oairevistaunincor@unincor.edu.br2236-53621517-0276opendoar:2022-05-31T14:30:30.700745Revista da Universidade Vale do Rio Verde (Online) - Universidade Vale do Rio Verde (UNINCOR)false
dc.title.none.fl_str_mv IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
title IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
spellingShingle IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
PIMENTA-MARTINS, Maria Gardenny Ribeiro; Universidade Estadual do Ceará
Ciência e Tecnologia de Alimentos; Química, Física, Físico-Química e Bioquí mica dos Alim. e das Mat.-Primas Alimentares
Screen-printed carbon (SPCE); Staphylococcal enterotoxin B; Biosensor; Food safety; Analysis.
Biossensor
title_short IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
title_full IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
title_fullStr IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
title_full_unstemmed IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
title_sort IMMUNOSENSOR BASED ON INK PRINTED ELECTRODE FOR STAPHYLOCOCCAL ENTEROTOXIN DETECTIONdoi: http://dx.doi.org/10.5892/ruvrd.v12i1.1400
author PIMENTA-MARTINS, Maria Gardenny Ribeiro; Universidade Estadual do Ceará
author_facet PIMENTA-MARTINS, Maria Gardenny Ribeiro; Universidade Estadual do Ceará
FURTADO, Roselayne Ferro
DUTRA, Rosa Fireman
HENEINE, Luiz Guilherme Dias
DIAS, Ricardo Souza
BORGES, Maria de Fátima
ALVES, Carlucio Roberto
author_role author
author2 FURTADO, Roselayne Ferro
DUTRA, Rosa Fireman
HENEINE, Luiz Guilherme Dias
DIAS, Ricardo Souza
BORGES, Maria de Fátima
ALVES, Carlucio Roberto
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv CNPq, FUNCAP, CAPES, Embrapa, FINEP
dc.contributor.author.fl_str_mv PIMENTA-MARTINS, Maria Gardenny Ribeiro; Universidade Estadual do Ceará
FURTADO, Roselayne Ferro
DUTRA, Rosa Fireman
HENEINE, Luiz Guilherme Dias
DIAS, Ricardo Souza
BORGES, Maria de Fátima
ALVES, Carlucio Roberto
dc.subject.por.fl_str_mv Ciência e Tecnologia de Alimentos; Química, Física, Físico-Química e Bioquí mica dos Alim. e das Mat.-Primas Alimentares
Screen-printed carbon (SPCE); Staphylococcal enterotoxin B; Biosensor; Food safety; Analysis.
Biossensor
topic Ciência e Tecnologia de Alimentos; Química, Física, Físico-Química e Bioquí mica dos Alim. e das Mat.-Primas Alimentares
Screen-printed carbon (SPCE); Staphylococcal enterotoxin B; Biosensor; Food safety; Analysis.
Biossensor
description Staphylococcal enterotoxin is one of the more aggressive enterotoxins produced by Staphylococcus aureus strains and it is a common cause of food poisoning. Analytical methods that are sensitive, low cost and easy to use are needed to evaluate the food quality. This work describes the development of a label free immunosensor based on screen-printed AuNPs/carbon and the characterization of its analytical response for staphylococcal enterotoxin B (SEB) detection. The biosensor was constructed from self-assembled monolayer of thiols and protein A for the oriented immobilization of the polyclonal antibodies against SEB. As electrons mediator, potassium ferrocyanide was used. The electrochemical detection was direct with the parameters following: -0.2 to 0.6 V with the pulse amplitude of 0.075 V and the pulse width of 75 ms. The immunosensor showed detection and quantification limits of 0.4 µg mL-1 and 1.6 µg mL-1,respectively. The immunosensor showed quite satisfactory performance in contaminated and non-contaminated cheese samples.
publishDate 2014
dc.date.none.fl_str_mv 2014-07-16
dc.type.none.fl_str_mv

dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://periodicos.unincor.br/index.php/revistaunincor/article/view/1400
10.5892/ruvrd.v12i1.1400
url http://periodicos.unincor.br/index.php/revistaunincor/article/view/1400
identifier_str_mv 10.5892/ruvrd.v12i1.1400
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv http://periodicos.unincor.br/index.php/revistaunincor/article/view/1400/pdf_172
10.5892/ruvrd.v12i1.1400.g1248
dc.rights.driver.fl_str_mv Direitos autorais 2021 Revista da Universidade Vale do Rio Verde
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Direitos autorais 2021 Revista da Universidade Vale do Rio Verde
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv


dc.publisher.none.fl_str_mv ABEC
publisher.none.fl_str_mv ABEC
dc.source.none.fl_str_mv Revista da Universidade Vale do Rio Verde; v. 12, n. 1 (2014); 895-904
2236-5362
1517-0276
10.5892/ruvrd.v12i1
reponame:Revista da Universidade Vale do Rio Verde (Online)
instname:Universidade Vale do Rio Verde (UNINCOR)
instacron:UVRV
instname_str Universidade Vale do Rio Verde (UNINCOR)
instacron_str UVRV
institution UVRV
reponame_str Revista da Universidade Vale do Rio Verde (Online)
collection Revista da Universidade Vale do Rio Verde (Online)
repository.name.fl_str_mv Revista da Universidade Vale do Rio Verde (Online) - Universidade Vale do Rio Verde (UNINCOR)
repository.mail.fl_str_mv revistaunincor@unincor.edu.br
_version_ 1797051201435467776