Film fraction in a vertical circular Venturi scrubber

Detalhes bibliográficos
Autor(a) principal: Guerra,Andressa Pinheiro
Data de Publicação: 2011
Outros Autores: Guerra,Vádila Giovana, Coury,José Renato, Gonçalves,José Antônio S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-58782011000500004
Resumo: The liquid film affects significantly the Venturi scrubber efficiency. Film fraction was measured in a vertically mounted laboratory scale Venturi scrubber with a 0.020 m throat diameter. The liquid was injected at the throat by one to six 0.001 m holes. The throat gas velocity varied from 50 to 90 m/s and the relative jet penetration varied between 0.05 and 0.85. A special test section with a slot was used to extract the film. The test section could be placed at different axial positions, allowing measurements at 0.0075, 0.0275 and 0.0675 m after the injection point. Results showed that film fraction varies as a function of the relative jet penetration and with distance from the injection point. There exists an optimal relative jet penetration (between 0.25 and 0.40) which minimizes film fraction. Film fraction increased with axial distance in the range studied, up to 3.375 throat diameters after the injection point.
id ABCM-2_64b055d124bfd8a8739506102c1e155d
oai_identifier_str oai:scielo:S1678-58782011000500004
network_acronym_str ABCM-2
network_name_str Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online)
repository_id_str
spelling Film fraction in a vertical circular Venturi scrubberfilm fractionVenturi scrubberjet penetrationThe liquid film affects significantly the Venturi scrubber efficiency. Film fraction was measured in a vertically mounted laboratory scale Venturi scrubber with a 0.020 m throat diameter. The liquid was injected at the throat by one to six 0.001 m holes. The throat gas velocity varied from 50 to 90 m/s and the relative jet penetration varied between 0.05 and 0.85. A special test section with a slot was used to extract the film. The test section could be placed at different axial positions, allowing measurements at 0.0075, 0.0275 and 0.0675 m after the injection point. Results showed that film fraction varies as a function of the relative jet penetration and with distance from the injection point. There exists an optimal relative jet penetration (between 0.25 and 0.40) which minimizes film fraction. Film fraction increased with axial distance in the range studied, up to 3.375 throat diameters after the injection point.Associação Brasileira de Engenharia e Ciências Mecânicas - ABCM2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-58782011000500004Journal of the Brazilian Society of Mechanical Sciences and Engineering v.33 n.spe1 2011reponame:Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online)instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)instacron:ABCM10.1590/S1678-58782011000500004info:eu-repo/semantics/openAccessGuerra,Andressa PinheiroGuerra,Vádila GiovanaCoury,José RenatoGonçalves,José Antônio S.eng2011-12-15T00:00:00Zoai:scielo:S1678-58782011000500004Revistahttps://www.scielo.br/j/jbsmse/https://old.scielo.br/oai/scielo-oai.php||abcm@abcm.org.br1806-36911678-5878opendoar:2011-12-15T00:00Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)false
dc.title.none.fl_str_mv Film fraction in a vertical circular Venturi scrubber
title Film fraction in a vertical circular Venturi scrubber
spellingShingle Film fraction in a vertical circular Venturi scrubber
Guerra,Andressa Pinheiro
film fraction
Venturi scrubber
jet penetration
title_short Film fraction in a vertical circular Venturi scrubber
title_full Film fraction in a vertical circular Venturi scrubber
title_fullStr Film fraction in a vertical circular Venturi scrubber
title_full_unstemmed Film fraction in a vertical circular Venturi scrubber
title_sort Film fraction in a vertical circular Venturi scrubber
author Guerra,Andressa Pinheiro
author_facet Guerra,Andressa Pinheiro
Guerra,Vádila Giovana
Coury,José Renato
Gonçalves,José Antônio S.
author_role author
author2 Guerra,Vádila Giovana
Coury,José Renato
Gonçalves,José Antônio S.
author2_role author
author
author
dc.contributor.author.fl_str_mv Guerra,Andressa Pinheiro
Guerra,Vádila Giovana
Coury,José Renato
Gonçalves,José Antônio S.
dc.subject.por.fl_str_mv film fraction
Venturi scrubber
jet penetration
topic film fraction
Venturi scrubber
jet penetration
description The liquid film affects significantly the Venturi scrubber efficiency. Film fraction was measured in a vertically mounted laboratory scale Venturi scrubber with a 0.020 m throat diameter. The liquid was injected at the throat by one to six 0.001 m holes. The throat gas velocity varied from 50 to 90 m/s and the relative jet penetration varied between 0.05 and 0.85. A special test section with a slot was used to extract the film. The test section could be placed at different axial positions, allowing measurements at 0.0075, 0.0275 and 0.0675 m after the injection point. Results showed that film fraction varies as a function of the relative jet penetration and with distance from the injection point. There exists an optimal relative jet penetration (between 0.25 and 0.40) which minimizes film fraction. Film fraction increased with axial distance in the range studied, up to 3.375 throat diameters after the injection point.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-58782011000500004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-58782011000500004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1678-58782011000500004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Engenharia e Ciências Mecânicas - ABCM
publisher.none.fl_str_mv Associação Brasileira de Engenharia e Ciências Mecânicas - ABCM
dc.source.none.fl_str_mv Journal of the Brazilian Society of Mechanical Sciences and Engineering v.33 n.spe1 2011
reponame:Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online)
instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
instacron:ABCM
instname_str Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
instacron_str ABCM
institution ABCM
reponame_str Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online)
collection Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online)
repository.name.fl_str_mv Journal of the Brazilian Society of Mechanical Sciences and Engineering (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
repository.mail.fl_str_mv ||abcm@abcm.org.br
_version_ 1754734681945800704