A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure

Detalhes bibliográficos
Autor(a) principal: Barroco,A.C.
Data de Publicação: 2017
Outros Autores: Sperandio,P.A., Reis,M., Almeida,D.R., Neder,J.A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Medical and Biological Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001200603
Resumo: Heart failure is characterized by the inability of the cardiovascular system to maintain oxygen (O2) delivery (i.e., muscle blood flow in non-hypoxemic patients) to meet O2 demands. The resulting increase in fractional O2 extraction can be non-invasively tracked by deoxygenated hemoglobin concentration (deoxi-Hb) as measured by near-infrared spectroscopy (NIRS). We aimed to establish a simplified approach to extract deoxi-Hb-based indices of impaired muscle O2 delivery during rapidly-incrementing exercise in heart failure. We continuously probed the right vastus lateralis muscle with continuous-wave NIRS during a ramp-incremental cardiopulmonary exercise test in 10 patients (left ventricular ejection fraction <35%) and 10 age-matched healthy males. Deoxi-Hb is reported as % of total response (onset to peak exercise) in relation to work rate. Patients showed lower maximum exercise capacity and O2 uptake-work rate than controls (P<0.05). The deoxi-Hb response profile as a function of work rate was S-shaped in all subjects, i.e., it presented three distinct phases. Increased muscle deoxygenation in patients compared to controls was demonstrated by: i) a steeper mid-exercise deoxi-Hb-work rate slope (2.2±1.3 vs 1.0±0.3% peak/W, respectively; P<0.05), and ii) late-exercise increase in deoxi-Hb, which contrasted with stable or decreasing deoxi-Hb in all controls. Steeper deoxi-Hb-work rate slope was associated with lower peak work rate in patients (r=–0.73; P=0.01). This simplified approach to deoxi-Hb interpretation might prove useful in clinical settings to quantify impairments in O2 delivery by NIRS during ramp-incremental exercise in individual heart failure patients.
id ABDC-1_4e7fbb18684773c81070927e3e407e0f
oai_identifier_str oai:scielo:S0100-879X2017001200603
network_acronym_str ABDC-1
network_name_str Brazilian Journal of Medical and Biological Research
repository_id_str
spelling A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failureHeart failureExerciseOxygenMuscleNear-infrared spectroscopyHeart failure is characterized by the inability of the cardiovascular system to maintain oxygen (O2) delivery (i.e., muscle blood flow in non-hypoxemic patients) to meet O2 demands. The resulting increase in fractional O2 extraction can be non-invasively tracked by deoxygenated hemoglobin concentration (deoxi-Hb) as measured by near-infrared spectroscopy (NIRS). We aimed to establish a simplified approach to extract deoxi-Hb-based indices of impaired muscle O2 delivery during rapidly-incrementing exercise in heart failure. We continuously probed the right vastus lateralis muscle with continuous-wave NIRS during a ramp-incremental cardiopulmonary exercise test in 10 patients (left ventricular ejection fraction <35%) and 10 age-matched healthy males. Deoxi-Hb is reported as % of total response (onset to peak exercise) in relation to work rate. Patients showed lower maximum exercise capacity and O2 uptake-work rate than controls (P<0.05). The deoxi-Hb response profile as a function of work rate was S-shaped in all subjects, i.e., it presented three distinct phases. Increased muscle deoxygenation in patients compared to controls was demonstrated by: i) a steeper mid-exercise deoxi-Hb-work rate slope (2.2±1.3 vs 1.0±0.3% peak/W, respectively; P<0.05), and ii) late-exercise increase in deoxi-Hb, which contrasted with stable or decreasing deoxi-Hb in all controls. Steeper deoxi-Hb-work rate slope was associated with lower peak work rate in patients (r=–0.73; P=0.01). This simplified approach to deoxi-Hb interpretation might prove useful in clinical settings to quantify impairments in O2 delivery by NIRS during ramp-incremental exercise in individual heart failure patients.Associação Brasileira de Divulgação Científica2017-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001200603Brazilian Journal of Medical and Biological Research v.50 n.12 2017reponame:Brazilian Journal of Medical and Biological Researchinstname:Associação Brasileira de Divulgação Científica (ABDC)instacron:ABDC10.1590/1414-431x20176327info:eu-repo/semantics/openAccessBarroco,A.C.Sperandio,P.A.Reis,M.Almeida,D.R.Neder,J.A.eng2019-03-19T00:00:00Zoai:scielo:S0100-879X2017001200603Revistahttps://www.bjournal.org/https://old.scielo.br/oai/scielo-oai.phpbjournal@terra.com.br||bjournal@terra.com.br1414-431X0100-879Xopendoar:2019-03-19T00:00Brazilian Journal of Medical and Biological Research - Associação Brasileira de Divulgação Científica (ABDC)false
dc.title.none.fl_str_mv A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
title A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
spellingShingle A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
Barroco,A.C.
Heart failure
Exercise
Oxygen
Muscle
Near-infrared spectroscopy
title_short A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
title_full A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
title_fullStr A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
title_full_unstemmed A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
title_sort A practical approach to assess leg muscle oxygenation during ramp-incremental cycle ergometry in heart failure
author Barroco,A.C.
author_facet Barroco,A.C.
Sperandio,P.A.
Reis,M.
Almeida,D.R.
Neder,J.A.
author_role author
author2 Sperandio,P.A.
Reis,M.
Almeida,D.R.
Neder,J.A.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Barroco,A.C.
Sperandio,P.A.
Reis,M.
Almeida,D.R.
Neder,J.A.
dc.subject.por.fl_str_mv Heart failure
Exercise
Oxygen
Muscle
Near-infrared spectroscopy
topic Heart failure
Exercise
Oxygen
Muscle
Near-infrared spectroscopy
description Heart failure is characterized by the inability of the cardiovascular system to maintain oxygen (O2) delivery (i.e., muscle blood flow in non-hypoxemic patients) to meet O2 demands. The resulting increase in fractional O2 extraction can be non-invasively tracked by deoxygenated hemoglobin concentration (deoxi-Hb) as measured by near-infrared spectroscopy (NIRS). We aimed to establish a simplified approach to extract deoxi-Hb-based indices of impaired muscle O2 delivery during rapidly-incrementing exercise in heart failure. We continuously probed the right vastus lateralis muscle with continuous-wave NIRS during a ramp-incremental cardiopulmonary exercise test in 10 patients (left ventricular ejection fraction <35%) and 10 age-matched healthy males. Deoxi-Hb is reported as % of total response (onset to peak exercise) in relation to work rate. Patients showed lower maximum exercise capacity and O2 uptake-work rate than controls (P<0.05). The deoxi-Hb response profile as a function of work rate was S-shaped in all subjects, i.e., it presented three distinct phases. Increased muscle deoxygenation in patients compared to controls was demonstrated by: i) a steeper mid-exercise deoxi-Hb-work rate slope (2.2±1.3 vs 1.0±0.3% peak/W, respectively; P<0.05), and ii) late-exercise increase in deoxi-Hb, which contrasted with stable or decreasing deoxi-Hb in all controls. Steeper deoxi-Hb-work rate slope was associated with lower peak work rate in patients (r=–0.73; P=0.01). This simplified approach to deoxi-Hb interpretation might prove useful in clinical settings to quantify impairments in O2 delivery by NIRS during ramp-incremental exercise in individual heart failure patients.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001200603
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001200603
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1414-431x20176327
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica
publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica
dc.source.none.fl_str_mv Brazilian Journal of Medical and Biological Research v.50 n.12 2017
reponame:Brazilian Journal of Medical and Biological Research
instname:Associação Brasileira de Divulgação Científica (ABDC)
instacron:ABDC
instname_str Associação Brasileira de Divulgação Científica (ABDC)
instacron_str ABDC
institution ABDC
reponame_str Brazilian Journal of Medical and Biological Research
collection Brazilian Journal of Medical and Biological Research
repository.name.fl_str_mv Brazilian Journal of Medical and Biological Research - Associação Brasileira de Divulgação Científica (ABDC)
repository.mail.fl_str_mv bjournal@terra.com.br||bjournal@terra.com.br
_version_ 1754302945913995264