A study of the drop size distributions and hold-up in short Kühni columns
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Chemical Engineering |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322008000400010 |
Resumo: | The hydrodynamic behaviour of a short Kühni column was investigated under no mass transfer conditions using the binary system water (continuous phase) and Exxsol D-80 (dispersed phase). The counter-current flow pattern of the liquid phases was characterised regarding the Sauter mean drop diameter, drop size distribution and hold-up; a photographic method was used to assess drop sizes. The following operating variables were studied: rotor speed, flow rate of both liquid phases and column stage. The log-normal probability density function was found to be adequate to fit the experimental drop size distributions along the column. As expected, smaller drops and more uniform drop size distributions were obtained with the increase of rotor speed and column stage number, thus indicating the predominance of drop breakage phenomena in short columns. The total hold-up was influenced mainly by rotor speed and flow rate of the dispersed phase. Recommended correlations available in the literature were found to be inadequate for predicting experimental drop sizes and hold-up, so alternative expressions, valid only for short Kühni columns, were proposed. |
id |
ABEQ-1_be87add9b66d0b618ff93adfa8b88c49 |
---|---|
oai_identifier_str |
oai:scielo:S0104-66322008000400010 |
network_acronym_str |
ABEQ-1 |
network_name_str |
Brazilian Journal of Chemical Engineering |
repository_id_str |
|
spelling |
A study of the drop size distributions and hold-up in short Kühni columnsLiquid-liquid extractionKühni columnHydrodynamicsDrop size distributionsShort columnsThe hydrodynamic behaviour of a short Kühni column was investigated under no mass transfer conditions using the binary system water (continuous phase) and Exxsol D-80 (dispersed phase). The counter-current flow pattern of the liquid phases was characterised regarding the Sauter mean drop diameter, drop size distribution and hold-up; a photographic method was used to assess drop sizes. The following operating variables were studied: rotor speed, flow rate of both liquid phases and column stage. The log-normal probability density function was found to be adequate to fit the experimental drop size distributions along the column. As expected, smaller drops and more uniform drop size distributions were obtained with the increase of rotor speed and column stage number, thus indicating the predominance of drop breakage phenomena in short columns. The total hold-up was influenced mainly by rotor speed and flow rate of the dispersed phase. Recommended correlations available in the literature were found to be inadequate for predicting experimental drop sizes and hold-up, so alternative expressions, valid only for short Kühni columns, were proposed.Brazilian Society of Chemical Engineering2008-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322008000400010Brazilian Journal of Chemical Engineering v.25 n.4 2008reponame:Brazilian Journal of Chemical Engineeringinstname:Associação Brasileira de Engenharia Química (ABEQ)instacron:ABEQ10.1590/S0104-66322008000400010info:eu-repo/semantics/openAccessOliveira,N. S.Silva,D. MoraesGondim,M. P. C.Mansur,M. Borgeseng2008-11-24T00:00:00Zoai:scielo:S0104-66322008000400010Revistahttps://www.scielo.br/j/bjce/https://old.scielo.br/oai/scielo-oai.phprgiudici@usp.br||rgiudici@usp.br1678-43830104-6632opendoar:2008-11-24T00:00Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ)false |
dc.title.none.fl_str_mv |
A study of the drop size distributions and hold-up in short Kühni columns |
title |
A study of the drop size distributions and hold-up in short Kühni columns |
spellingShingle |
A study of the drop size distributions and hold-up in short Kühni columns Oliveira,N. S. Liquid-liquid extraction Kühni column Hydrodynamics Drop size distributions Short columns |
title_short |
A study of the drop size distributions and hold-up in short Kühni columns |
title_full |
A study of the drop size distributions and hold-up in short Kühni columns |
title_fullStr |
A study of the drop size distributions and hold-up in short Kühni columns |
title_full_unstemmed |
A study of the drop size distributions and hold-up in short Kühni columns |
title_sort |
A study of the drop size distributions and hold-up in short Kühni columns |
author |
Oliveira,N. S. |
author_facet |
Oliveira,N. S. Silva,D. Moraes Gondim,M. P. C. Mansur,M. Borges |
author_role |
author |
author2 |
Silva,D. Moraes Gondim,M. P. C. Mansur,M. Borges |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Oliveira,N. S. Silva,D. Moraes Gondim,M. P. C. Mansur,M. Borges |
dc.subject.por.fl_str_mv |
Liquid-liquid extraction Kühni column Hydrodynamics Drop size distributions Short columns |
topic |
Liquid-liquid extraction Kühni column Hydrodynamics Drop size distributions Short columns |
description |
The hydrodynamic behaviour of a short Kühni column was investigated under no mass transfer conditions using the binary system water (continuous phase) and Exxsol D-80 (dispersed phase). The counter-current flow pattern of the liquid phases was characterised regarding the Sauter mean drop diameter, drop size distribution and hold-up; a photographic method was used to assess drop sizes. The following operating variables were studied: rotor speed, flow rate of both liquid phases and column stage. The log-normal probability density function was found to be adequate to fit the experimental drop size distributions along the column. As expected, smaller drops and more uniform drop size distributions were obtained with the increase of rotor speed and column stage number, thus indicating the predominance of drop breakage phenomena in short columns. The total hold-up was influenced mainly by rotor speed and flow rate of the dispersed phase. Recommended correlations available in the literature were found to be inadequate for predicting experimental drop sizes and hold-up, so alternative expressions, valid only for short Kühni columns, were proposed. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322008000400010 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322008000400010 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0104-66322008000400010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
dc.source.none.fl_str_mv |
Brazilian Journal of Chemical Engineering v.25 n.4 2008 reponame:Brazilian Journal of Chemical Engineering instname:Associação Brasileira de Engenharia Química (ABEQ) instacron:ABEQ |
instname_str |
Associação Brasileira de Engenharia Química (ABEQ) |
instacron_str |
ABEQ |
institution |
ABEQ |
reponame_str |
Brazilian Journal of Chemical Engineering |
collection |
Brazilian Journal of Chemical Engineering |
repository.name.fl_str_mv |
Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ) |
repository.mail.fl_str_mv |
rgiudici@usp.br||rgiudici@usp.br |
_version_ |
1754213172702609408 |