Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Chemical Engineering |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322014000300022 |
Resumo: | Isobaric vapor-liquid equilibrium (VLE) data for the cyclopentane and tetrahydrofuran (THF) system were measured at 101.3 kPa by using an equilibrium still. Thermodynamic consistency of the experimental data was confirmed by means of the Herington method. The experimental data were correlated and calculated by the Margules, Van Laar and Wilson activity-coefficient models, respectively. The Wilson and Van Laar activity-coefficient models are better than the Margules activity-coefficient model based on the average absolute deviations of temperature and the vapor-phase composition. For the Wilson and Van Laar activity-coefficient models the average absolute deviations between the experimental and the calculated values were 0.24 K and 0.23 K for the boiling point, and 0.0040 for vapor-phase composition, respectively. These agree well with the experimental data. Therefore, it was shown that the Wilson and Van Laar activity-coefficient models satisfactorily correlate the experimental results of the cyclopentane and tetrahydrofuran system. |
id |
ABEQ-1_db2e7416821009b8690fa20bad63ceac |
---|---|
oai_identifier_str |
oai:scielo:S0104-66322014000300022 |
network_acronym_str |
ABEQ-1 |
network_name_str |
Brazilian Journal of Chemical Engineering |
repository_id_str |
|
spelling |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuranCyclopentaneTetrahydrofuranVapor-liquid equilibriumIsobaric vapor-liquid equilibrium (VLE) data for the cyclopentane and tetrahydrofuran (THF) system were measured at 101.3 kPa by using an equilibrium still. Thermodynamic consistency of the experimental data was confirmed by means of the Herington method. The experimental data were correlated and calculated by the Margules, Van Laar and Wilson activity-coefficient models, respectively. The Wilson and Van Laar activity-coefficient models are better than the Margules activity-coefficient model based on the average absolute deviations of temperature and the vapor-phase composition. For the Wilson and Van Laar activity-coefficient models the average absolute deviations between the experimental and the calculated values were 0.24 K and 0.23 K for the boiling point, and 0.0040 for vapor-phase composition, respectively. These agree well with the experimental data. Therefore, it was shown that the Wilson and Van Laar activity-coefficient models satisfactorily correlate the experimental results of the cyclopentane and tetrahydrofuran system.Brazilian Society of Chemical Engineering2014-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322014000300022Brazilian Journal of Chemical Engineering v.31 n.3 2014reponame:Brazilian Journal of Chemical Engineeringinstname:Associação Brasileira de Engenharia Química (ABEQ)instacron:ABEQ10.1590/0104-6632.20140313s00002623info:eu-repo/semantics/openAccessLi,Yumeieng2014-09-17T00:00:00Zoai:scielo:S0104-66322014000300022Revistahttps://www.scielo.br/j/bjce/https://old.scielo.br/oai/scielo-oai.phprgiudici@usp.br||rgiudici@usp.br1678-43830104-6632opendoar:2014-09-17T00:00Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ)false |
dc.title.none.fl_str_mv |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran |
title |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran |
spellingShingle |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran Li,Yumei Cyclopentane Tetrahydrofuran Vapor-liquid equilibrium |
title_short |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran |
title_full |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran |
title_fullStr |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran |
title_full_unstemmed |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran |
title_sort |
Measurement and correlation of isobaric vapor-liquid equilibrium for the binary system of cyclopentane and tetrahydrofuran |
author |
Li,Yumei |
author_facet |
Li,Yumei |
author_role |
author |
dc.contributor.author.fl_str_mv |
Li,Yumei |
dc.subject.por.fl_str_mv |
Cyclopentane Tetrahydrofuran Vapor-liquid equilibrium |
topic |
Cyclopentane Tetrahydrofuran Vapor-liquid equilibrium |
description |
Isobaric vapor-liquid equilibrium (VLE) data for the cyclopentane and tetrahydrofuran (THF) system were measured at 101.3 kPa by using an equilibrium still. Thermodynamic consistency of the experimental data was confirmed by means of the Herington method. The experimental data were correlated and calculated by the Margules, Van Laar and Wilson activity-coefficient models, respectively. The Wilson and Van Laar activity-coefficient models are better than the Margules activity-coefficient model based on the average absolute deviations of temperature and the vapor-phase composition. For the Wilson and Van Laar activity-coefficient models the average absolute deviations between the experimental and the calculated values were 0.24 K and 0.23 K for the boiling point, and 0.0040 for vapor-phase composition, respectively. These agree well with the experimental data. Therefore, it was shown that the Wilson and Van Laar activity-coefficient models satisfactorily correlate the experimental results of the cyclopentane and tetrahydrofuran system. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322014000300022 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322014000300022 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0104-6632.20140313s00002623 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
dc.source.none.fl_str_mv |
Brazilian Journal of Chemical Engineering v.31 n.3 2014 reponame:Brazilian Journal of Chemical Engineering instname:Associação Brasileira de Engenharia Química (ABEQ) instacron:ABEQ |
instname_str |
Associação Brasileira de Engenharia Química (ABEQ) |
instacron_str |
ABEQ |
institution |
ABEQ |
reponame_str |
Brazilian Journal of Chemical Engineering |
collection |
Brazilian Journal of Chemical Engineering |
repository.name.fl_str_mv |
Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ) |
repository.mail.fl_str_mv |
rgiudici@usp.br||rgiudici@usp.br |
_version_ |
1754213174600531968 |