Performance of a pulsed-cap microcolumn for protein extraction
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Chemical Engineering |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322003000400003 |
Resumo: | This work presents the results obtained using a microcolumn agitated by pulsed caps, using aqueous two-phase systems formed polyethylene glycol and salts (monobasic and dibasic) potassium phosphate for protein extraction. Proteins used were extracted cytochrome b5 and the enzyme ascorbic oxidoreductase. It was observed that operation of this equipment was stable and high efficiency values were achieved. |
id |
ABEQ-1_ebb086ef012fb4da03cc8a2cbc01fe4a |
---|---|
oai_identifier_str |
oai:scielo:S0104-66322003000400003 |
network_acronym_str |
ABEQ-1 |
network_name_str |
Brazilian Journal of Chemical Engineering |
repository_id_str |
|
spelling |
Performance of a pulsed-cap microcolumn for protein extractionaqueous two-phase systemdownstream processingcontinuous extraction equipmentproteinpurificationsolvent extractionThis work presents the results obtained using a microcolumn agitated by pulsed caps, using aqueous two-phase systems formed polyethylene glycol and salts (monobasic and dibasic) potassium phosphate for protein extraction. Proteins used were extracted cytochrome b5 and the enzyme ascorbic oxidoreductase. It was observed that operation of this equipment was stable and high efficiency values were achieved.Brazilian Society of Chemical Engineering2003-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322003000400003Brazilian Journal of Chemical Engineering v.20 n.4 2003reponame:Brazilian Journal of Chemical Engineeringinstname:Associação Brasileira de Engenharia Química (ABEQ)instacron:ABEQ10.1590/S0104-66322003000400003info:eu-repo/semantics/openAccessRabelo,A.P.B.Tambourgi,E.B.eng2003-12-04T00:00:00Zoai:scielo:S0104-66322003000400003Revistahttps://www.scielo.br/j/bjce/https://old.scielo.br/oai/scielo-oai.phprgiudici@usp.br||rgiudici@usp.br1678-43830104-6632opendoar:2003-12-04T00:00Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ)false |
dc.title.none.fl_str_mv |
Performance of a pulsed-cap microcolumn for protein extraction |
title |
Performance of a pulsed-cap microcolumn for protein extraction |
spellingShingle |
Performance of a pulsed-cap microcolumn for protein extraction Rabelo,A.P.B. aqueous two-phase system downstream processing continuous extraction equipment protein purification solvent extraction |
title_short |
Performance of a pulsed-cap microcolumn for protein extraction |
title_full |
Performance of a pulsed-cap microcolumn for protein extraction |
title_fullStr |
Performance of a pulsed-cap microcolumn for protein extraction |
title_full_unstemmed |
Performance of a pulsed-cap microcolumn for protein extraction |
title_sort |
Performance of a pulsed-cap microcolumn for protein extraction |
author |
Rabelo,A.P.B. |
author_facet |
Rabelo,A.P.B. Tambourgi,E.B. |
author_role |
author |
author2 |
Tambourgi,E.B. |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Rabelo,A.P.B. Tambourgi,E.B. |
dc.subject.por.fl_str_mv |
aqueous two-phase system downstream processing continuous extraction equipment protein purification solvent extraction |
topic |
aqueous two-phase system downstream processing continuous extraction equipment protein purification solvent extraction |
description |
This work presents the results obtained using a microcolumn agitated by pulsed caps, using aqueous two-phase systems formed polyethylene glycol and salts (monobasic and dibasic) potassium phosphate for protein extraction. Proteins used were extracted cytochrome b5 and the enzyme ascorbic oxidoreductase. It was observed that operation of this equipment was stable and high efficiency values were achieved. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322003000400003 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322003000400003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0104-66322003000400003 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
dc.source.none.fl_str_mv |
Brazilian Journal of Chemical Engineering v.20 n.4 2003 reponame:Brazilian Journal of Chemical Engineering instname:Associação Brasileira de Engenharia Química (ABEQ) instacron:ABEQ |
instname_str |
Associação Brasileira de Engenharia Química (ABEQ) |
instacron_str |
ABEQ |
institution |
ABEQ |
reponame_str |
Brazilian Journal of Chemical Engineering |
collection |
Brazilian Journal of Chemical Engineering |
repository.name.fl_str_mv |
Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ) |
repository.mail.fl_str_mv |
rgiudici@usp.br||rgiudici@usp.br |
_version_ |
1754213171499892736 |