Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista brasileira de hematologia e hemoterapia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178 |
Resumo: | Objective: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test prob- ability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. Methods: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 µg/L in women and a cord blood serum ferritin <35.0 µg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. Results: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 µg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). Conclusion: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns. |
id |
ABHHTC-1_01129c33a8bf45b90e247d95066cc50f |
---|---|
oai_identifier_str |
oai:scielo:S1516-84842015000300178 |
network_acronym_str |
ABHHTC-1 |
network_name_str |
Revista brasileira de hematologia e hemoterapia (Online) |
repository_id_str |
|
spelling |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysisFerritinsAnemia, Iron-deficiencyDiagnostic tests, Routine Objective: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test prob- ability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. Methods: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 µg/L in women and a cord blood serum ferritin <35.0 µg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. Results: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 µg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). Conclusion: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns. Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular2015-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178Revista Brasileira de Hematologia e Hemoterapia v.37 n.3 2015reponame:Revista brasileira de hematologia e hemoterapia (Online)instname:Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC)instacron:ABHHTC10.1016/j.bjhh.2015.02.002info:eu-repo/semantics/openAccessJaime-Pérez,José CarlosGarcía-Arellano,GiselaMéndez-Ramírez,NereidaGonzález-Llano,ÓscarGómez-Almaguer,Davideng2015-07-17T00:00:00Zoai:scielo:S1516-84842015000300178Revistahttp://www.rbhh.org/pt/archivo/https://old.scielo.br/oai/scielo-oai.phpsbhh@terra.com.br||secretaria@rbhh.org1806-08701516-8484opendoar:2015-07-17T00:00Revista brasileira de hematologia e hemoterapia (Online) - Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC)false |
dc.title.none.fl_str_mv |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
spellingShingle |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis Jaime-Pérez,José Carlos Ferritins Anemia, Iron-deficiency Diagnostic tests, Routine |
title_short |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_full |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_fullStr |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_full_unstemmed |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
title_sort |
Evaluation of hemoglobin performance in the assessment of iron stores in feto-maternal pairs in a high-risk population: receiver operating characteristic curve analysis |
author |
Jaime-Pérez,José Carlos |
author_facet |
Jaime-Pérez,José Carlos García-Arellano,Gisela Méndez-Ramírez,Nereida González-Llano,Óscar Gómez-Almaguer,David |
author_role |
author |
author2 |
García-Arellano,Gisela Méndez-Ramírez,Nereida González-Llano,Óscar Gómez-Almaguer,David |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Jaime-Pérez,José Carlos García-Arellano,Gisela Méndez-Ramírez,Nereida González-Llano,Óscar Gómez-Almaguer,David |
dc.subject.por.fl_str_mv |
Ferritins Anemia, Iron-deficiency Diagnostic tests, Routine |
topic |
Ferritins Anemia, Iron-deficiency Diagnostic tests, Routine |
description |
Objective: By applying receiver operating characteristic curve analysis, the objective of this study was to see whether hemoglobin levels reflect body iron stores in a group of pregnant women at term who, by using serum ferritin as the reference test, had a high pre-test prob- ability of having iron deficiency anemia. Likewise, we evaluated the ability of hemoglobin and maternal serum ferritin levels to predict iron deficiency anemia in newborns. Methods: Hemoglobin and serum ferritin were measured in 187 pregnant women at term belonging to a group with a high pre-test probability of iron deficiency anemia and their newborns. Women with Hb <11.0 g/dL and newborns with cord Hb <13.0 g/dL were classified as anemic. A serum ferritin <12.0 µg/L in women and a cord blood serum ferritin <35.0 µg/L were considered to reflect empty iron stores. Receiver operating characteristic curve analysis was applied to select the cut-off points that better reflected iron stores. Results: The Hb cut-off point selected by receiver operating characteristic curve analysis in women was <11.5 g/dL (sensitivity: 60.82, specificity: 53.33%, Youden Index: 0.450). Most of the newborns had normal Hb which precluded this analysis. Maternal Hb <11.0 g/dL was the cut-off point that best reflected iron deficiency anemia in newborns (sensitivity: 55.88%, specificity: 57.24%, Youden Index: 0.217). The best cut-off point of maternal serum ferritin to reflect empty iron stores in newborns was <6.0 µg/L (sensitivity: 76.47%, specificity: 31.58%, Youden Index: 0.200). Conclusion: Hemoglobin concentration performed poorly to detect iron deficiency anemia in women at term with high risk for iron deficiency and their newborns. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-84842015000300178 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.bjhh.2015.02.002 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular |
publisher.none.fl_str_mv |
Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular |
dc.source.none.fl_str_mv |
Revista Brasileira de Hematologia e Hemoterapia v.37 n.3 2015 reponame:Revista brasileira de hematologia e hemoterapia (Online) instname:Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC) instacron:ABHHTC |
instname_str |
Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC) |
instacron_str |
ABHHTC |
institution |
ABHHTC |
reponame_str |
Revista brasileira de hematologia e hemoterapia (Online) |
collection |
Revista brasileira de hematologia e hemoterapia (Online) |
repository.name.fl_str_mv |
Revista brasileira de hematologia e hemoterapia (Online) - Associação Brasileira de Hematologia e Hemoterapia e Terapia Celular (ABHHTC) |
repository.mail.fl_str_mv |
sbhh@terra.com.br||secretaria@rbhh.org |
_version_ |
1754213112460869632 |