Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials

Detalhes bibliográficos
Autor(a) principal: Torres,Fernanda Ferrari Esteves
Data de Publicação: 2020
Outros Autores: Guerreiro-Tanomaru,Juliane Maria, Bosso-Martelo,Roberta, Espir,Camila Galletti, Pinto,Jáder Camilo, Tanomaru-Filho,Mário
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Materials research (São Carlos. Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392020000400211
Resumo: Abstract Dental materials should be stable over time. This study investigated volumetric change of the root canal sealers AH Plus, Fill Canal, and Sealapex; and the root-end filling materials Biodentine, IRM, and MTA after different periods of immersion in distilled water. Resin models were manufactured with cavities 3 mm deep. The cavities were filled with the materials and scanned by microcomputed tomography after setting, and after 7 and 30 days immersed in distilled water. Percentages of volumetric changes after 7 and 30 days of immersion were compared by t-test. ANOVA/Tukey tests were used to compare endodontic materials (5% significance level). All root canal sealers had an increase in their volumetric change after 30 days. Among root-end filling materials, only IRM showed difference between the periods. Biodentine showed more volumetric changes than MTA, but both materials kept their volume from 7 to 30 days. In conclusion, the immersion period of endodontic materials may affect their stability.
id ABMABCABPOL-1_146b29ba0be2b1fd1cce3e9fa6d06557
oai_identifier_str oai:scielo:S1516-14392020000400211
network_acronym_str ABMABCABPOL-1
network_name_str Materials research (São Carlos. Online)
repository_id_str
spelling Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic MaterialsDental materialsendodonticsphysical propertiesx-ray microtomographyAbstract Dental materials should be stable over time. This study investigated volumetric change of the root canal sealers AH Plus, Fill Canal, and Sealapex; and the root-end filling materials Biodentine, IRM, and MTA after different periods of immersion in distilled water. Resin models were manufactured with cavities 3 mm deep. The cavities were filled with the materials and scanned by microcomputed tomography after setting, and after 7 and 30 days immersed in distilled water. Percentages of volumetric changes after 7 and 30 days of immersion were compared by t-test. ANOVA/Tukey tests were used to compare endodontic materials (5% significance level). All root canal sealers had an increase in their volumetric change after 30 days. Among root-end filling materials, only IRM showed difference between the periods. Biodentine showed more volumetric changes than MTA, but both materials kept their volume from 7 to 30 days. In conclusion, the immersion period of endodontic materials may affect their stability.ABM, ABC, ABPol2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392020000400211Materials Research v.23 n.4 2020reponame:Materials research (São Carlos. Online)instname:Universidade Federal de São Carlos (UFSCAR)instacron:ABM ABC ABPOL10.1590/1980-5373-mr-2020-0201info:eu-repo/semantics/openAccessTorres,Fernanda Ferrari EstevesGuerreiro-Tanomaru,Juliane MariaBosso-Martelo,RobertaEspir,Camila GallettiPinto,Jáder CamiloTanomaru-Filho,Márioeng2020-08-13T00:00:00Zoai:scielo:S1516-14392020000400211Revistahttp://www.scielo.br/mrPUBhttps://old.scielo.br/oai/scielo-oai.phpdedz@power.ufscar.br1980-53731516-1439opendoar:2020-08-13T00:00Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)false
dc.title.none.fl_str_mv Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
title Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
spellingShingle Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
Torres,Fernanda Ferrari Esteves
Dental materials
endodontics
physical properties
x-ray microtomography
title_short Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
title_full Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
title_fullStr Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
title_full_unstemmed Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
title_sort Micro-computed Tomography Analysis of the Effect of Immersion Time on Volumetric Stability of Different Endodontic Materials
author Torres,Fernanda Ferrari Esteves
author_facet Torres,Fernanda Ferrari Esteves
Guerreiro-Tanomaru,Juliane Maria
Bosso-Martelo,Roberta
Espir,Camila Galletti
Pinto,Jáder Camilo
Tanomaru-Filho,Mário
author_role author
author2 Guerreiro-Tanomaru,Juliane Maria
Bosso-Martelo,Roberta
Espir,Camila Galletti
Pinto,Jáder Camilo
Tanomaru-Filho,Mário
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Torres,Fernanda Ferrari Esteves
Guerreiro-Tanomaru,Juliane Maria
Bosso-Martelo,Roberta
Espir,Camila Galletti
Pinto,Jáder Camilo
Tanomaru-Filho,Mário
dc.subject.por.fl_str_mv Dental materials
endodontics
physical properties
x-ray microtomography
topic Dental materials
endodontics
physical properties
x-ray microtomography
description Abstract Dental materials should be stable over time. This study investigated volumetric change of the root canal sealers AH Plus, Fill Canal, and Sealapex; and the root-end filling materials Biodentine, IRM, and MTA after different periods of immersion in distilled water. Resin models were manufactured with cavities 3 mm deep. The cavities were filled with the materials and scanned by microcomputed tomography after setting, and after 7 and 30 days immersed in distilled water. Percentages of volumetric changes after 7 and 30 days of immersion were compared by t-test. ANOVA/Tukey tests were used to compare endodontic materials (5% significance level). All root canal sealers had an increase in their volumetric change after 30 days. Among root-end filling materials, only IRM showed difference between the periods. Biodentine showed more volumetric changes than MTA, but both materials kept their volume from 7 to 30 days. In conclusion, the immersion period of endodontic materials may affect their stability.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392020000400211
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392020000400211
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1980-5373-mr-2020-0201
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ABM, ABC, ABPol
publisher.none.fl_str_mv ABM, ABC, ABPol
dc.source.none.fl_str_mv Materials Research v.23 n.4 2020
reponame:Materials research (São Carlos. Online)
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:ABM ABC ABPOL
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str ABM ABC ABPOL
institution ABM ABC ABPOL
reponame_str Materials research (São Carlos. Online)
collection Materials research (São Carlos. Online)
repository.name.fl_str_mv Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv dedz@power.ufscar.br
_version_ 1754212677385715712