Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy
Main Author: | |
---|---|
Publication Date: | 2010 |
Other Authors: | , , |
Format: | Article |
Language: | eng |
Source: | Materials research (São Carlos. Online) |
Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000100009 |
Summary: | Despite the interest in identifying systemic effects caused by the metallic particles released from long term metallic implants in the body, few works support reliable conclusions about the effects of those particles in organs. The aim of the present work is to look for damages in tissues of liver, kidney, lung and heart of rats submitted to injection of Hank's solution contained particles of Ti6Al4V alloy and Stainless Steel 316L, obtained by metal friction. The particles size ranges from 50 to 200 µm for the Ti alloy and from 100 to 500 µm for the 316L. Tissues isolated from the organs after the euthanasia were prepared and analyzed in an optical microscope and Energy Dispersive Spectrometer (EDS). Lesions caused by an inflammatory response such as strange body epithelioid granuloma and giant cells were found in some of the tissues containing yttrium and aluminum. |
id |
ABMABCABPOL-1_3b7ae0fd29a9386c5154bc0df0c81f84 |
---|---|
oai_identifier_str |
oai:scielo:S1516-14392010000100009 |
network_acronym_str |
ABMABCABPOL-1 |
network_name_str |
Materials research (São Carlos. Online) |
repository_id_str |
|
spelling |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloymetallic implantsparticles releasein vivo testTi6Al4V alloystainless steel 316LDespite the interest in identifying systemic effects caused by the metallic particles released from long term metallic implants in the body, few works support reliable conclusions about the effects of those particles in organs. The aim of the present work is to look for damages in tissues of liver, kidney, lung and heart of rats submitted to injection of Hank's solution contained particles of Ti6Al4V alloy and Stainless Steel 316L, obtained by metal friction. The particles size ranges from 50 to 200 µm for the Ti alloy and from 100 to 500 µm for the 316L. Tissues isolated from the organs after the euthanasia were prepared and analyzed in an optical microscope and Energy Dispersive Spectrometer (EDS). Lesions caused by an inflammatory response such as strange body epithelioid granuloma and giant cells were found in some of the tissues containing yttrium and aluminum.ABM, ABC, ABPol2010-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000100009Materials Research v.13 n.1 2010reponame:Materials research (São Carlos. Online)instname:Universidade Federal de São Carlos (UFSCAR)instacron:ABM ABC ABPOL10.1590/S1516-14392010000100009info:eu-repo/semantics/openAccessGiertz,Silvia HelenaFernandes,Beatriz LuciFernandes,Carlos RobertoFranco,Celia Regina Cavichioloeng2010-04-13T00:00:00Zoai:scielo:S1516-14392010000100009Revistahttp://www.scielo.br/mrPUBhttps://old.scielo.br/oai/scielo-oai.phpdedz@power.ufscar.br1980-53731516-1439opendoar:2010-04-13T00:00Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.none.fl_str_mv |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy |
title |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy |
spellingShingle |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy Giertz,Silvia Helena metallic implants particles release in vivo test Ti6Al4V alloy stainless steel 316L |
title_short |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy |
title_full |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy |
title_fullStr |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy |
title_full_unstemmed |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy |
title_sort |
Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy |
author |
Giertz,Silvia Helena |
author_facet |
Giertz,Silvia Helena Fernandes,Beatriz Luci Fernandes,Carlos Roberto Franco,Celia Regina Cavichiolo |
author_role |
author |
author2 |
Fernandes,Beatriz Luci Fernandes,Carlos Roberto Franco,Celia Regina Cavichiolo |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Giertz,Silvia Helena Fernandes,Beatriz Luci Fernandes,Carlos Roberto Franco,Celia Regina Cavichiolo |
dc.subject.por.fl_str_mv |
metallic implants particles release in vivo test Ti6Al4V alloy stainless steel 316L |
topic |
metallic implants particles release in vivo test Ti6Al4V alloy stainless steel 316L |
description |
Despite the interest in identifying systemic effects caused by the metallic particles released from long term metallic implants in the body, few works support reliable conclusions about the effects of those particles in organs. The aim of the present work is to look for damages in tissues of liver, kidney, lung and heart of rats submitted to injection of Hank's solution contained particles of Ti6Al4V alloy and Stainless Steel 316L, obtained by metal friction. The particles size ranges from 50 to 200 µm for the Ti alloy and from 100 to 500 µm for the 316L. Tissues isolated from the organs after the euthanasia were prepared and analyzed in an optical microscope and Energy Dispersive Spectrometer (EDS). Lesions caused by an inflammatory response such as strange body epithelioid granuloma and giant cells were found in some of the tissues containing yttrium and aluminum. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000100009 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000100009 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-14392010000100009 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ABM, ABC, ABPol |
publisher.none.fl_str_mv |
ABM, ABC, ABPol |
dc.source.none.fl_str_mv |
Materials Research v.13 n.1 2010 reponame:Materials research (São Carlos. Online) instname:Universidade Federal de São Carlos (UFSCAR) instacron:ABM ABC ABPOL |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
ABM ABC ABPOL |
institution |
ABM ABC ABPOL |
reponame_str |
Materials research (São Carlos. Online) |
collection |
Materials research (São Carlos. Online) |
repository.name.fl_str_mv |
Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
dedz@power.ufscar.br |
_version_ |
1754212659357548544 |