Effect of exposure time vs. irradiance on knoop hardness of dental composites
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Materials research (São Carlos. Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392006000300006 |
Resumo: | A comparison was made of the hardness of Z250 and Esthet-X composites light cured with different light sources. Cavities (3 mm diameter x 6 mm deep) were prepared in 240 bovine incisors. The composite was bulk inserted and light-cured using halogen light, LED or xenon plasma arc (PAC) with different irradiances and exposure times, maintaining the same energy density. The specimens were stored in an incubator at 37 °C for 24 hours prior to sectioning for hardness measurements. Three measurements were taken at each depth: surface, 1, 2, 3, 4 and 5 mm. The data were analyzed by ANOVA and Tukey's test (p < 0.05). No statistically significant differences were found for LED up to 2 mm, for PAC up to 3 mm, and for halogen light up to 5 mm. Photoactivation with intermediate power density and exposure time resulted in the highest Knoop hardness values. |
id |
ABMABCABPOL-1_88ed09fa37271adc90349772ff8b7c36 |
---|---|
oai_identifier_str |
oai:scielo:S1516-14392006000300006 |
network_acronym_str |
ABMABCABPOL-1 |
network_name_str |
Materials research (São Carlos. Online) |
repository_id_str |
|
spelling |
Effect of exposure time vs. irradiance on knoop hardness of dental compositescomposite resinenergy densityKnoop hardnesslight curingA comparison was made of the hardness of Z250 and Esthet-X composites light cured with different light sources. Cavities (3 mm diameter x 6 mm deep) were prepared in 240 bovine incisors. The composite was bulk inserted and light-cured using halogen light, LED or xenon plasma arc (PAC) with different irradiances and exposure times, maintaining the same energy density. The specimens were stored in an incubator at 37 °C for 24 hours prior to sectioning for hardness measurements. Three measurements were taken at each depth: surface, 1, 2, 3, 4 and 5 mm. The data were analyzed by ANOVA and Tukey's test (p < 0.05). No statistically significant differences were found for LED up to 2 mm, for PAC up to 3 mm, and for halogen light up to 5 mm. Photoactivation with intermediate power density and exposure time resulted in the highest Knoop hardness values.ABM, ABC, ABPol2006-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392006000300006Materials Research v.9 n.3 2006reponame:Materials research (São Carlos. Online)instname:Universidade Federal de São Carlos (UFSCAR)instacron:ABM ABC ABPOL10.1590/S1516-14392006000300006info:eu-repo/semantics/openAccessCorrer,Américo BortolazzoSinhoreti,Mário Alexandre CoelhoCorrer-Sobrinho,LourençoTango,Rubens NisieConsani,SimonidesSchneider,Luis Felipe Jochinseng2006-10-19T00:00:00Zoai:scielo:S1516-14392006000300006Revistahttp://www.scielo.br/mrPUBhttps://old.scielo.br/oai/scielo-oai.phpdedz@power.ufscar.br1980-53731516-1439opendoar:2006-10-19T00:00Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.none.fl_str_mv |
Effect of exposure time vs. irradiance on knoop hardness of dental composites |
title |
Effect of exposure time vs. irradiance on knoop hardness of dental composites |
spellingShingle |
Effect of exposure time vs. irradiance on knoop hardness of dental composites Correr,Américo Bortolazzo composite resin energy density Knoop hardness light curing |
title_short |
Effect of exposure time vs. irradiance on knoop hardness of dental composites |
title_full |
Effect of exposure time vs. irradiance on knoop hardness of dental composites |
title_fullStr |
Effect of exposure time vs. irradiance on knoop hardness of dental composites |
title_full_unstemmed |
Effect of exposure time vs. irradiance on knoop hardness of dental composites |
title_sort |
Effect of exposure time vs. irradiance on knoop hardness of dental composites |
author |
Correr,Américo Bortolazzo |
author_facet |
Correr,Américo Bortolazzo Sinhoreti,Mário Alexandre Coelho Correr-Sobrinho,Lourenço Tango,Rubens Nisie Consani,Simonides Schneider,Luis Felipe Jochins |
author_role |
author |
author2 |
Sinhoreti,Mário Alexandre Coelho Correr-Sobrinho,Lourenço Tango,Rubens Nisie Consani,Simonides Schneider,Luis Felipe Jochins |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Correr,Américo Bortolazzo Sinhoreti,Mário Alexandre Coelho Correr-Sobrinho,Lourenço Tango,Rubens Nisie Consani,Simonides Schneider,Luis Felipe Jochins |
dc.subject.por.fl_str_mv |
composite resin energy density Knoop hardness light curing |
topic |
composite resin energy density Knoop hardness light curing |
description |
A comparison was made of the hardness of Z250 and Esthet-X composites light cured with different light sources. Cavities (3 mm diameter x 6 mm deep) were prepared in 240 bovine incisors. The composite was bulk inserted and light-cured using halogen light, LED or xenon plasma arc (PAC) with different irradiances and exposure times, maintaining the same energy density. The specimens were stored in an incubator at 37 °C for 24 hours prior to sectioning for hardness measurements. Three measurements were taken at each depth: surface, 1, 2, 3, 4 and 5 mm. The data were analyzed by ANOVA and Tukey's test (p < 0.05). No statistically significant differences were found for LED up to 2 mm, for PAC up to 3 mm, and for halogen light up to 5 mm. Photoactivation with intermediate power density and exposure time resulted in the highest Knoop hardness values. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392006000300006 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392006000300006 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-14392006000300006 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ABM, ABC, ABPol |
publisher.none.fl_str_mv |
ABM, ABC, ABPol |
dc.source.none.fl_str_mv |
Materials Research v.9 n.3 2006 reponame:Materials research (São Carlos. Online) instname:Universidade Federal de São Carlos (UFSCAR) instacron:ABM ABC ABPOL |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
ABM ABC ABPOL |
institution |
ABM ABC ABPOL |
reponame_str |
Materials research (São Carlos. Online) |
collection |
Materials research (São Carlos. Online) |
repository.name.fl_str_mv |
Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
dedz@power.ufscar.br |
_version_ |
1754212658463113216 |