Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Materials research (São Carlos. Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000200008 |
Resumo: | As new orthodontic resin adhesives continue to be marketed, rapid and sensitive tests for examining their toxic effects at the ' cell and tissue level ' are needed because patient safety has been identifi ed as a legal concept. The objective of the present study was to evaluate the cytotoxicity and degree of monomer conversion of orthodontic adhesives over different time periods. Seven adhesives: Transbond® XT, Transbond® Color Change, Quick Cure, EagleBond, Orthobond®, Fill Mágic® and Biofix® were evaluated for their cytotoxicity in L929 fibroblastic cells and for their degree of monomer conversion over different time periods. Three control groups were also analysed: Positive control (C+), consisting of Tween 80 cell detergent; Negative control (C-), consisting of PBS; and cell control (CC), consisting of cells exposed to any material. The dye-uptake technique that involves the absorption of a neutral red dye in viable cells was used for the cytotoxicity evaluation and the degree of conversion was evaluated using spectroscopy with infrared. The results showed the cytotoxicity of the adhesives at 24, 48, 72 and 168 hours. At these times, the viability values presented for these materials were statistically different from the groups CC and C- (p < 0.05). At 168 hours, all the groups showed low cytotoxicity with high cell viability and with no statistical difference with the groups CC and C- (P > 0.05). In the monomer conversions there was a percentage increase of monomer conversion from 24 to 72 hours. A direct correlation could be observed between cytotoxicity and monomer conversions. From this work it can be concluded that all adhesives evaluated are cytotoxic at the times of 24, 48 and 72 hours. Monomers continued conversion even after photopolymerization had stopped. |
id |
ABMABCABPOL-1_898d1d4f3a1bba9a54a8768d011c79d7 |
---|---|
oai_identifier_str |
oai:scielo:S1516-14392010000200008 |
network_acronym_str |
ABMABCABPOL-1 |
network_name_str |
Materials research (São Carlos. Online) |
repository_id_str |
|
spelling |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periodscytotoxicitydegree of conversionfibroblastsdental compositesAs new orthodontic resin adhesives continue to be marketed, rapid and sensitive tests for examining their toxic effects at the ' cell and tissue level ' are needed because patient safety has been identifi ed as a legal concept. The objective of the present study was to evaluate the cytotoxicity and degree of monomer conversion of orthodontic adhesives over different time periods. Seven adhesives: Transbond® XT, Transbond® Color Change, Quick Cure, EagleBond, Orthobond®, Fill Mágic® and Biofix® were evaluated for their cytotoxicity in L929 fibroblastic cells and for their degree of monomer conversion over different time periods. Three control groups were also analysed: Positive control (C+), consisting of Tween 80 cell detergent; Negative control (C-), consisting of PBS; and cell control (CC), consisting of cells exposed to any material. The dye-uptake technique that involves the absorption of a neutral red dye in viable cells was used for the cytotoxicity evaluation and the degree of conversion was evaluated using spectroscopy with infrared. The results showed the cytotoxicity of the adhesives at 24, 48, 72 and 168 hours. At these times, the viability values presented for these materials were statistically different from the groups CC and C- (p < 0.05). At 168 hours, all the groups showed low cytotoxicity with high cell viability and with no statistical difference with the groups CC and C- (P > 0.05). In the monomer conversions there was a percentage increase of monomer conversion from 24 to 72 hours. A direct correlation could be observed between cytotoxicity and monomer conversions. From this work it can be concluded that all adhesives evaluated are cytotoxic at the times of 24, 48 and 72 hours. Monomers continued conversion even after photopolymerization had stopped.ABM, ABC, ABPol2010-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000200008Materials Research v.13 n.2 2010reponame:Materials research (São Carlos. Online)instname:Universidade Federal de São Carlos (UFSCAR)instacron:ABM ABC ABPOL10.1590/S1516-14392010000200008info:eu-repo/semantics/openAccessPithon,Matheus MeloSantos,Rogério Lacerda dosMartins,Fernanda OtavianoRomanos,Maria Teresa VillelaAraújo,Mônica Tirre de Souzaeng2010-07-16T00:00:00Zoai:scielo:S1516-14392010000200008Revistahttp://www.scielo.br/mrPUBhttps://old.scielo.br/oai/scielo-oai.phpdedz@power.ufscar.br1980-53731516-1439opendoar:2010-07-16T00:00Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.none.fl_str_mv |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods |
title |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods |
spellingShingle |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods Pithon,Matheus Melo cytotoxicity degree of conversion fibroblasts dental composites |
title_short |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods |
title_full |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods |
title_fullStr |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods |
title_full_unstemmed |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods |
title_sort |
Evaluation of cytotoxicity and degree of conversion of orthodontic adhesives over different time periods |
author |
Pithon,Matheus Melo |
author_facet |
Pithon,Matheus Melo Santos,Rogério Lacerda dos Martins,Fernanda Otaviano Romanos,Maria Teresa Villela Araújo,Mônica Tirre de Souza |
author_role |
author |
author2 |
Santos,Rogério Lacerda dos Martins,Fernanda Otaviano Romanos,Maria Teresa Villela Araújo,Mônica Tirre de Souza |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Pithon,Matheus Melo Santos,Rogério Lacerda dos Martins,Fernanda Otaviano Romanos,Maria Teresa Villela Araújo,Mônica Tirre de Souza |
dc.subject.por.fl_str_mv |
cytotoxicity degree of conversion fibroblasts dental composites |
topic |
cytotoxicity degree of conversion fibroblasts dental composites |
description |
As new orthodontic resin adhesives continue to be marketed, rapid and sensitive tests for examining their toxic effects at the ' cell and tissue level ' are needed because patient safety has been identifi ed as a legal concept. The objective of the present study was to evaluate the cytotoxicity and degree of monomer conversion of orthodontic adhesives over different time periods. Seven adhesives: Transbond® XT, Transbond® Color Change, Quick Cure, EagleBond, Orthobond®, Fill Mágic® and Biofix® were evaluated for their cytotoxicity in L929 fibroblastic cells and for their degree of monomer conversion over different time periods. Three control groups were also analysed: Positive control (C+), consisting of Tween 80 cell detergent; Negative control (C-), consisting of PBS; and cell control (CC), consisting of cells exposed to any material. The dye-uptake technique that involves the absorption of a neutral red dye in viable cells was used for the cytotoxicity evaluation and the degree of conversion was evaluated using spectroscopy with infrared. The results showed the cytotoxicity of the adhesives at 24, 48, 72 and 168 hours. At these times, the viability values presented for these materials were statistically different from the groups CC and C- (p < 0.05). At 168 hours, all the groups showed low cytotoxicity with high cell viability and with no statistical difference with the groups CC and C- (P > 0.05). In the monomer conversions there was a percentage increase of monomer conversion from 24 to 72 hours. A direct correlation could be observed between cytotoxicity and monomer conversions. From this work it can be concluded that all adhesives evaluated are cytotoxic at the times of 24, 48 and 72 hours. Monomers continued conversion even after photopolymerization had stopped. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000200008 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000200008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-14392010000200008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ABM, ABC, ABPol |
publisher.none.fl_str_mv |
ABM, ABC, ABPol |
dc.source.none.fl_str_mv |
Materials Research v.13 n.2 2010 reponame:Materials research (São Carlos. Online) instname:Universidade Federal de São Carlos (UFSCAR) instacron:ABM ABC ABPOL |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
ABM ABC ABPOL |
institution |
ABM ABC ABPOL |
reponame_str |
Materials research (São Carlos. Online) |
collection |
Materials research (São Carlos. Online) |
repository.name.fl_str_mv |
Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
dedz@power.ufscar.br |
_version_ |
1754212659639615488 |