The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma

Detalhes bibliográficos
Autor(a) principal: Çelik,Kaan
Data de Publicação: 2021
Outros Autores: Demiryurek,Bekir Enes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos de neuro-psiquiatria (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021001000879
Resumo: Abstract Background: Although intracranial pressure (ICP) monitoring is the gold standard method for measuring intracranial pressure after traumatic brain injury, optic nerve sheath diameter (ONSD) measurement with ultrasound (US) is also used in the evaluation of ICP. Objective: To investigate the association between a series of OSND measurements by US and changes in clinical presentation of the patient. Methods: Prospective study including 162 patients with traumatic brain injury. Age, sex, cerebral CT findings, ONSD levels by US at minutes 0, 60, and 120, Glasgow Coma Scale (GCS) within same period, change of consciousness, treatment, and mortality data were reviewed. The association of ONSD levels with GCS, change of consciousness, treatment, and mortality was evaluated. Results: There was no difference in ONSD changes in the patients’ sample within the period (p=0.326). ONSD significantly increased in patients who died (p<0.001), but not in those who survived (p=0.938). There was no significant change in ONSD of the patients who received anti-edema therapy (p=801), but significantly increased ONSD values were found in those who received anti-edema therapy (p=0.03). Patients without change of consciousness did not have any significant change in ONSD (p=0.672), but ONSD values increased in patients who consciousness became worse, and decreased in those who presented a recovery (respectively, p<0.001, p=0.002). A negative correlation was detected between ONSD values and GSC values measured at primary, secondary, and tertiary time periods (for all p<0.001). Conclusions: ONSD follow-up may be useful to monitor ICP increase in patients with acute traumatic brain injury.
id ABNEURO-1_cfb025b83623b8b60a6721ab85fd286e
oai_identifier_str oai:scielo:S0004-282X2021001000879
network_acronym_str ABNEURO-1
network_name_str Arquivos de neuro-psiquiatria (Online)
repository_id_str
spelling The association between intracranial pressure and optic nerve sheath diameter on patients with head traumaBrain Injuries, TraumaticOptic Nerve NeoplasmsGlasgow Coma ScaleMortalityAbstract Background: Although intracranial pressure (ICP) monitoring is the gold standard method for measuring intracranial pressure after traumatic brain injury, optic nerve sheath diameter (ONSD) measurement with ultrasound (US) is also used in the evaluation of ICP. Objective: To investigate the association between a series of OSND measurements by US and changes in clinical presentation of the patient. Methods: Prospective study including 162 patients with traumatic brain injury. Age, sex, cerebral CT findings, ONSD levels by US at minutes 0, 60, and 120, Glasgow Coma Scale (GCS) within same period, change of consciousness, treatment, and mortality data were reviewed. The association of ONSD levels with GCS, change of consciousness, treatment, and mortality was evaluated. Results: There was no difference in ONSD changes in the patients’ sample within the period (p=0.326). ONSD significantly increased in patients who died (p<0.001), but not in those who survived (p=0.938). There was no significant change in ONSD of the patients who received anti-edema therapy (p=801), but significantly increased ONSD values were found in those who received anti-edema therapy (p=0.03). Patients without change of consciousness did not have any significant change in ONSD (p=0.672), but ONSD values increased in patients who consciousness became worse, and decreased in those who presented a recovery (respectively, p<0.001, p=0.002). A negative correlation was detected between ONSD values and GSC values measured at primary, secondary, and tertiary time periods (for all p<0.001). Conclusions: ONSD follow-up may be useful to monitor ICP increase in patients with acute traumatic brain injury.Academia Brasileira de Neurologia - ABNEURO2021-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021001000879Arquivos de Neuro-Psiquiatria v.79 n.10 2021reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/0004-282x-anp-2020-0478info:eu-repo/semantics/openAccessÇelik,KaanDemiryurek,Bekir Eneseng2021-10-21T00:00:00Zoai:scielo:S0004-282X2021001000879Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2021-10-21T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse
dc.title.none.fl_str_mv The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
title The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
spellingShingle The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
Çelik,Kaan
Brain Injuries, Traumatic
Optic Nerve Neoplasms
Glasgow Coma Scale
Mortality
title_short The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
title_full The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
title_fullStr The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
title_full_unstemmed The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
title_sort The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
author Çelik,Kaan
author_facet Çelik,Kaan
Demiryurek,Bekir Enes
author_role author
author2 Demiryurek,Bekir Enes
author2_role author
dc.contributor.author.fl_str_mv Çelik,Kaan
Demiryurek,Bekir Enes
dc.subject.por.fl_str_mv Brain Injuries, Traumatic
Optic Nerve Neoplasms
Glasgow Coma Scale
Mortality
topic Brain Injuries, Traumatic
Optic Nerve Neoplasms
Glasgow Coma Scale
Mortality
description Abstract Background: Although intracranial pressure (ICP) monitoring is the gold standard method for measuring intracranial pressure after traumatic brain injury, optic nerve sheath diameter (ONSD) measurement with ultrasound (US) is also used in the evaluation of ICP. Objective: To investigate the association between a series of OSND measurements by US and changes in clinical presentation of the patient. Methods: Prospective study including 162 patients with traumatic brain injury. Age, sex, cerebral CT findings, ONSD levels by US at minutes 0, 60, and 120, Glasgow Coma Scale (GCS) within same period, change of consciousness, treatment, and mortality data were reviewed. The association of ONSD levels with GCS, change of consciousness, treatment, and mortality was evaluated. Results: There was no difference in ONSD changes in the patients’ sample within the period (p=0.326). ONSD significantly increased in patients who died (p<0.001), but not in those who survived (p=0.938). There was no significant change in ONSD of the patients who received anti-edema therapy (p=801), but significantly increased ONSD values were found in those who received anti-edema therapy (p=0.03). Patients without change of consciousness did not have any significant change in ONSD (p=0.672), but ONSD values increased in patients who consciousness became worse, and decreased in those who presented a recovery (respectively, p<0.001, p=0.002). A negative correlation was detected between ONSD values and GSC values measured at primary, secondary, and tertiary time periods (for all p<0.001). Conclusions: ONSD follow-up may be useful to monitor ICP increase in patients with acute traumatic brain injury.
publishDate 2021
dc.date.none.fl_str_mv 2021-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021001000879
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021001000879
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0004-282x-anp-2020-0478
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
dc.source.none.fl_str_mv Arquivos de Neuro-Psiquiatria v.79 n.10 2021
reponame:Arquivos de neuro-psiquiatria (Online)
instname:Academia Brasileira de Neurologia
instacron:ABNEURO
instname_str Academia Brasileira de Neurologia
instacron_str ABNEURO
institution ABNEURO
reponame_str Arquivos de neuro-psiquiatria (Online)
collection Arquivos de neuro-psiquiatria (Online)
repository.name.fl_str_mv Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia
repository.mail.fl_str_mv ||revista.arquivos@abneuro.org
_version_ 1754212789422915584