Can the adapted arcometer be used to assess the vertebral column in children?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Physical Therapy |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552014000600538 |
Resumo: | BACKGROUND: The adapted arcometer has been validated for use in adults. However, its suitability for use in children can be questioned given the structural differences present in these populations. OBJECTIVE: To verify the concurrent validity, repeatability, and intra- and inter-reproducibility of the adapted arcometer for the measurement of the angles of thoracic kyphosis and lumbar lordosis in children. METHOD: Forty children were evaluated using both sagittal radiography of the spine and the adapted arcometer. The evaluations using the arcometer were carried out by two trained evaluators on two different days. In the statistical treatment, the intraclass correlation coefficient (ICC), Pearson's product moment correlation, Spearman's rho, the paired t test, and Wilcoxon's test were used (α=.05). RESULTS: A moderate and significant correlation was found between the x-ray and the adapted arcometer regarding thoracic kyphosis, but no correlation was found regarding lumbar lordosis. Repeatability and intra-evaluator reproducibility of the thoracic kyphosis and lumbar lordosis were confirmed, which was not the case of inter-evaluator reproducibility. CONCLUSION: The adapted arcometer can be used to accompany postural alterations in children made by the same evaluator, while its use for diagnostic purposes and continued evaluation by different evaluators cannot be recommended. Further studies with the aim of adapting this instrument for use in children are recommended. |
id |
ABRA-FT-1_38443ba2d486310cbda949771cba2eac |
---|---|
oai_identifier_str |
oai:scielo:S1413-35552014000600538 |
network_acronym_str |
ABRA-FT-1 |
network_name_str |
Brazilian Journal of Physical Therapy |
repository_id_str |
|
spelling |
Can the adapted arcometer be used to assess the vertebral column in children?physical therapyevaluationspinechildrenvalidity of tests BACKGROUND: The adapted arcometer has been validated for use in adults. However, its suitability for use in children can be questioned given the structural differences present in these populations. OBJECTIVE: To verify the concurrent validity, repeatability, and intra- and inter-reproducibility of the adapted arcometer for the measurement of the angles of thoracic kyphosis and lumbar lordosis in children. METHOD: Forty children were evaluated using both sagittal radiography of the spine and the adapted arcometer. The evaluations using the arcometer were carried out by two trained evaluators on two different days. In the statistical treatment, the intraclass correlation coefficient (ICC), Pearson's product moment correlation, Spearman's rho, the paired t test, and Wilcoxon's test were used (α=.05). RESULTS: A moderate and significant correlation was found between the x-ray and the adapted arcometer regarding thoracic kyphosis, but no correlation was found regarding lumbar lordosis. Repeatability and intra-evaluator reproducibility of the thoracic kyphosis and lumbar lordosis were confirmed, which was not the case of inter-evaluator reproducibility. CONCLUSION: The adapted arcometer can be used to accompany postural alterations in children made by the same evaluator, while its use for diagnostic purposes and continued evaluation by different evaluators cannot be recommended. Further studies with the aim of adapting this instrument for use in children are recommended. Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552014000600538Brazilian Journal of Physical Therapy v.18 n.6 2014reponame:Brazilian Journal of Physical Therapyinstname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)instacron:ABRAPG-FT10.1590/bjpt-rbf.2014.0060info:eu-repo/semantics/openAccessSedrez,Juliana A.Candotti,Cláudia T.Medeiros,Fernanda S.Marques,Mariana T.Rosa,Maria I. Z.Loss,Jefferson F.eng2015-08-21T00:00:00Zoai:scielo:S1413-35552014000600538Revistahttps://www.scielo.br/j/rbfis/https://old.scielo.br/oai/scielo-oai.phpcontato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br1809-92461413-3555opendoar:2015-08-21T00:00Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)false |
dc.title.none.fl_str_mv |
Can the adapted arcometer be used to assess the vertebral column in children? |
title |
Can the adapted arcometer be used to assess the vertebral column in children? |
spellingShingle |
Can the adapted arcometer be used to assess the vertebral column in children? Sedrez,Juliana A. physical therapy evaluation spine children validity of tests |
title_short |
Can the adapted arcometer be used to assess the vertebral column in children? |
title_full |
Can the adapted arcometer be used to assess the vertebral column in children? |
title_fullStr |
Can the adapted arcometer be used to assess the vertebral column in children? |
title_full_unstemmed |
Can the adapted arcometer be used to assess the vertebral column in children? |
title_sort |
Can the adapted arcometer be used to assess the vertebral column in children? |
author |
Sedrez,Juliana A. |
author_facet |
Sedrez,Juliana A. Candotti,Cláudia T. Medeiros,Fernanda S. Marques,Mariana T. Rosa,Maria I. Z. Loss,Jefferson F. |
author_role |
author |
author2 |
Candotti,Cláudia T. Medeiros,Fernanda S. Marques,Mariana T. Rosa,Maria I. Z. Loss,Jefferson F. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Sedrez,Juliana A. Candotti,Cláudia T. Medeiros,Fernanda S. Marques,Mariana T. Rosa,Maria I. Z. Loss,Jefferson F. |
dc.subject.por.fl_str_mv |
physical therapy evaluation spine children validity of tests |
topic |
physical therapy evaluation spine children validity of tests |
description |
BACKGROUND: The adapted arcometer has been validated for use in adults. However, its suitability for use in children can be questioned given the structural differences present in these populations. OBJECTIVE: To verify the concurrent validity, repeatability, and intra- and inter-reproducibility of the adapted arcometer for the measurement of the angles of thoracic kyphosis and lumbar lordosis in children. METHOD: Forty children were evaluated using both sagittal radiography of the spine and the adapted arcometer. The evaluations using the arcometer were carried out by two trained evaluators on two different days. In the statistical treatment, the intraclass correlation coefficient (ICC), Pearson's product moment correlation, Spearman's rho, the paired t test, and Wilcoxon's test were used (α=.05). RESULTS: A moderate and significant correlation was found between the x-ray and the adapted arcometer regarding thoracic kyphosis, but no correlation was found regarding lumbar lordosis. Repeatability and intra-evaluator reproducibility of the thoracic kyphosis and lumbar lordosis were confirmed, which was not the case of inter-evaluator reproducibility. CONCLUSION: The adapted arcometer can be used to accompany postural alterations in children made by the same evaluator, while its use for diagnostic purposes and continued evaluation by different evaluators cannot be recommended. Further studies with the aim of adapting this instrument for use in children are recommended. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552014000600538 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552014000600538 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/bjpt-rbf.2014.0060 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia |
publisher.none.fl_str_mv |
Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia |
dc.source.none.fl_str_mv |
Brazilian Journal of Physical Therapy v.18 n.6 2014 reponame:Brazilian Journal of Physical Therapy instname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT) instacron:ABRAPG-FT |
instname_str |
Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT) |
instacron_str |
ABRAPG-FT |
institution |
ABRAPG-FT |
reponame_str |
Brazilian Journal of Physical Therapy |
collection |
Brazilian Journal of Physical Therapy |
repository.name.fl_str_mv |
Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT) |
repository.mail.fl_str_mv |
contato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br |
_version_ |
1754575950092173312 |