Resumo: SUMMARY OBJECTIVE This study aims to investigate the causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography (TVS RT-3D-HyCoSy), in order to improve the diagnostic efficiency of TVS RT-3D-HyCoSy. METHODS A total of 162 oviducts of 83 infertility patients were examined by TVS RT-3D-HyCoSy. These results were compared with the gold standard for laparoscopic dye studies, and the misdiagnosed cases were analyzed. RESULTS TVS RT-3D-HyCoSy revealed that 68 oviducts were unobstructed and 94 obstructed. The results for the 144 oviducts were in line with the gold standard, while those for 18 oviducts were not. The accuracy rate of the TVS RT-3D-HyCoSy was 88.9%, and the misdiagnosis rate was 11.1%. The main causes of misdiagnosis included contrast medium countercurrent and diffusion, oviduct spasm, abnormal shape or position of the oviduct, pelvic adhesion, and poor imaging operation. CONCLUSION TVS RT-3D-HyCoSy can well-evaluate tubal patency, and understand and improve the cause of misdiagnosis. Furthermore, the diagnostic efficiency of TVS RT-3D-HyCoSy can still be further improved.
id AMB-1_59e953882e47c6befeb08d76acee9569
oai_identifier_str oai:scielo:S0104-42302019000801055
network_acronym_str AMB-1
network_name_str Revista da Associação Médica Brasileira (Online)
repository_id_str
spelling Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonographyHysterosalpingographyInfertilityDiagnostic Techniques, Obstetrical and GynecologicalDiagnostic ErrorsSUMMARY OBJECTIVE This study aims to investigate the causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography (TVS RT-3D-HyCoSy), in order to improve the diagnostic efficiency of TVS RT-3D-HyCoSy. METHODS A total of 162 oviducts of 83 infertility patients were examined by TVS RT-3D-HyCoSy. These results were compared with the gold standard for laparoscopic dye studies, and the misdiagnosed cases were analyzed. RESULTS TVS RT-3D-HyCoSy revealed that 68 oviducts were unobstructed and 94 obstructed. The results for the 144 oviducts were in line with the gold standard, while those for 18 oviducts were not. The accuracy rate of the TVS RT-3D-HyCoSy was 88.9%, and the misdiagnosis rate was 11.1%. The main causes of misdiagnosis included contrast medium countercurrent and diffusion, oviduct spasm, abnormal shape or position of the oviduct, pelvic adhesion, and poor imaging operation. CONCLUSION TVS RT-3D-HyCoSy can well-evaluate tubal patency, and understand and improve the cause of misdiagnosis. Furthermore, the diagnostic efficiency of TVS RT-3D-HyCoSy can still be further improved.Associação Médica Brasileira2019-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302019000801055Revista da Associação Médica Brasileira v.65 n.8 2019reponame:Revista da Associação Médica Brasileira (Online)instname:Associação Médica Brasileira (AMB)instacron:AMB10.1590/1806-9282.65.8.1055info:eu-repo/semantics/openAccessLiang,NaWu,Qing-QingLi,Jing-HuaGao,Feng-YunSun,Fu-LiGuo,Cui-Xiaeng2020-01-20T00:00:00Zoai:scielo:S0104-42302019000801055Revistahttps://ramb.amb.org.br/ultimas-edicoes/#https://old.scielo.br/oai/scielo-oai.php||ramb@amb.org.br1806-92820104-4230opendoar:2020-01-20T00:00Revista da Associação Médica Brasileira (Online) - Associação Médica Brasileira (AMB)false
dc.title.none.fl_str_mv Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
title Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
spellingShingle Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
Liang,Na
Hysterosalpingography
Infertility
Diagnostic Techniques, Obstetrical and Gynecological
Diagnostic Errors
title_short Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
title_full Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
title_fullStr Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
title_full_unstemmed Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
title_sort Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
author Liang,Na
author_facet Liang,Na
Wu,Qing-Qing
Li,Jing-Hua
Gao,Feng-Yun
Sun,Fu-Li
Guo,Cui-Xia
author_role author
author2 Wu,Qing-Qing
Li,Jing-Hua
Gao,Feng-Yun
Sun,Fu-Li
Guo,Cui-Xia
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Liang,Na
Wu,Qing-Qing
Li,Jing-Hua
Gao,Feng-Yun
Sun,Fu-Li
Guo,Cui-Xia
dc.subject.por.fl_str_mv Hysterosalpingography
Infertility
Diagnostic Techniques, Obstetrical and Gynecological
Diagnostic Errors
topic Hysterosalpingography
Infertility
Diagnostic Techniques, Obstetrical and Gynecological
Diagnostic Errors
description SUMMARY OBJECTIVE This study aims to investigate the causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography (TVS RT-3D-HyCoSy), in order to improve the diagnostic efficiency of TVS RT-3D-HyCoSy. METHODS A total of 162 oviducts of 83 infertility patients were examined by TVS RT-3D-HyCoSy. These results were compared with the gold standard for laparoscopic dye studies, and the misdiagnosed cases were analyzed. RESULTS TVS RT-3D-HyCoSy revealed that 68 oviducts were unobstructed and 94 obstructed. The results for the 144 oviducts were in line with the gold standard, while those for 18 oviducts were not. The accuracy rate of the TVS RT-3D-HyCoSy was 88.9%, and the misdiagnosis rate was 11.1%. The main causes of misdiagnosis included contrast medium countercurrent and diffusion, oviduct spasm, abnormal shape or position of the oviduct, pelvic adhesion, and poor imaging operation. CONCLUSION TVS RT-3D-HyCoSy can well-evaluate tubal patency, and understand and improve the cause of misdiagnosis. Furthermore, the diagnostic efficiency of TVS RT-3D-HyCoSy can still be further improved.
publishDate 2019
dc.date.none.fl_str_mv 2019-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302019000801055
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302019000801055
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1806-9282.65.8.1055
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Médica Brasileira
publisher.none.fl_str_mv Associação Médica Brasileira
dc.source.none.fl_str_mv Revista da Associação Médica Brasileira v.65 n.8 2019
reponame:Revista da Associação Médica Brasileira (Online)
instname:Associação Médica Brasileira (AMB)
instacron:AMB
instname_str Associação Médica Brasileira (AMB)
instacron_str AMB
institution AMB
reponame_str Revista da Associação Médica Brasileira (Online)
collection Revista da Associação Médica Brasileira (Online)
repository.name.fl_str_mv Revista da Associação Médica Brasileira (Online) - Associação Médica Brasileira (AMB)
repository.mail.fl_str_mv ||ramb@amb.org.br
_version_ 1754212834290434048