Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients

Detalhes bibliográficos
Autor(a) principal: Rose,Sara Cardoso Paes
Data de Publicação: 2020
Outros Autores: Cunha,Débora Vilela, Medeiros,Sandra de Barros Cobra, Trevizoli,José Eduardo, Carneiro,Marcos de Vasconcelos, Freitas,Wladimir Magalhães de, Mendes,Liliana Sampaio Costa
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista da Associação Médica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020001101577
Resumo: SUMMARY Hepatopulmonary Syndrome (HPS) is a complication of cirrhosis that worsens the disease's prognosis, pre and post liver transplant. The objective of this study is to analyze the prevalence of HPS in cirrhotic patients at our service and to correlate it with oxygen saturation (SatO2) using a pulse oximeter to evaluate if this is useful as a screening test for HPS. A prospective study was conducted in patients with hepatic cirrhosis conventionally selected from 2014 to 2016. All the patients underwent an echocardiogram with microbubbles and oxygen saturation measurement by pulse oximetry. Those with intrapulmonary shunt were submitted to arterial blood gas analysis. The relationship between oxygen saturation and HPS was assessed by the multivariate model of binary logistic regression. We analyzed 77 patients, and 23.3% (18 patients) had all criteria for HPS. The relationship between HPS and SatO2 did not show statistical significance, even after the variables were adjusted for sex, age, and smoking. Oxygen saturation alone was not able to detect HPS in the sample of cirrhotic patients. More accurate methods for screening and diagnosis of the syndrome should be used.
id AMB-1_66b6ac589edb62d62560e814e9d5440b
oai_identifier_str oai:scielo:S0104-42302020001101577
network_acronym_str AMB-1
network_name_str Revista da Associação Médica Brasileira (Online)
repository_id_str
spelling Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patientsHepatopulmonary syndromeOximetryTriageSUMMARY Hepatopulmonary Syndrome (HPS) is a complication of cirrhosis that worsens the disease's prognosis, pre and post liver transplant. The objective of this study is to analyze the prevalence of HPS in cirrhotic patients at our service and to correlate it with oxygen saturation (SatO2) using a pulse oximeter to evaluate if this is useful as a screening test for HPS. A prospective study was conducted in patients with hepatic cirrhosis conventionally selected from 2014 to 2016. All the patients underwent an echocardiogram with microbubbles and oxygen saturation measurement by pulse oximetry. Those with intrapulmonary shunt were submitted to arterial blood gas analysis. The relationship between oxygen saturation and HPS was assessed by the multivariate model of binary logistic regression. We analyzed 77 patients, and 23.3% (18 patients) had all criteria for HPS. The relationship between HPS and SatO2 did not show statistical significance, even after the variables were adjusted for sex, age, and smoking. Oxygen saturation alone was not able to detect HPS in the sample of cirrhotic patients. More accurate methods for screening and diagnosis of the syndrome should be used.Associação Médica Brasileira2020-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020001101577Revista da Associação Médica Brasileira v.66 n.11 2020reponame:Revista da Associação Médica Brasileira (Online)instname:Associação Médica Brasileira (AMB)instacron:AMB10.1590/1806-9282.66.11.1577info:eu-repo/semantics/openAccessRose,Sara Cardoso PaesCunha,Débora VilelaMedeiros,Sandra de Barros CobraTrevizoli,José EduardoCarneiro,Marcos de VasconcelosFreitas,Wladimir Magalhães deMendes,Liliana Sampaio Costaeng2020-11-30T00:00:00Zoai:scielo:S0104-42302020001101577Revistahttps://ramb.amb.org.br/ultimas-edicoes/#https://old.scielo.br/oai/scielo-oai.php||ramb@amb.org.br1806-92820104-4230opendoar:2020-11-30T00:00Revista da Associação Médica Brasileira (Online) - Associação Médica Brasileira (AMB)false
dc.title.none.fl_str_mv Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
title Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
spellingShingle Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
Rose,Sara Cardoso Paes
Hepatopulmonary syndrome
Oximetry
Triage
title_short Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
title_full Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
title_fullStr Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
title_full_unstemmed Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
title_sort Correlation between hepatopulmonary syndrome and oxygen saturation pulse oximetry in cirrhotic patients
author Rose,Sara Cardoso Paes
author_facet Rose,Sara Cardoso Paes
Cunha,Débora Vilela
Medeiros,Sandra de Barros Cobra
Trevizoli,José Eduardo
Carneiro,Marcos de Vasconcelos
Freitas,Wladimir Magalhães de
Mendes,Liliana Sampaio Costa
author_role author
author2 Cunha,Débora Vilela
Medeiros,Sandra de Barros Cobra
Trevizoli,José Eduardo
Carneiro,Marcos de Vasconcelos
Freitas,Wladimir Magalhães de
Mendes,Liliana Sampaio Costa
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Rose,Sara Cardoso Paes
Cunha,Débora Vilela
Medeiros,Sandra de Barros Cobra
Trevizoli,José Eduardo
Carneiro,Marcos de Vasconcelos
Freitas,Wladimir Magalhães de
Mendes,Liliana Sampaio Costa
dc.subject.por.fl_str_mv Hepatopulmonary syndrome
Oximetry
Triage
topic Hepatopulmonary syndrome
Oximetry
Triage
description SUMMARY Hepatopulmonary Syndrome (HPS) is a complication of cirrhosis that worsens the disease's prognosis, pre and post liver transplant. The objective of this study is to analyze the prevalence of HPS in cirrhotic patients at our service and to correlate it with oxygen saturation (SatO2) using a pulse oximeter to evaluate if this is useful as a screening test for HPS. A prospective study was conducted in patients with hepatic cirrhosis conventionally selected from 2014 to 2016. All the patients underwent an echocardiogram with microbubbles and oxygen saturation measurement by pulse oximetry. Those with intrapulmonary shunt were submitted to arterial blood gas analysis. The relationship between oxygen saturation and HPS was assessed by the multivariate model of binary logistic regression. We analyzed 77 patients, and 23.3% (18 patients) had all criteria for HPS. The relationship between HPS and SatO2 did not show statistical significance, even after the variables were adjusted for sex, age, and smoking. Oxygen saturation alone was not able to detect HPS in the sample of cirrhotic patients. More accurate methods for screening and diagnosis of the syndrome should be used.
publishDate 2020
dc.date.none.fl_str_mv 2020-11-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020001101577
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020001101577
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1806-9282.66.11.1577
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Médica Brasileira
publisher.none.fl_str_mv Associação Médica Brasileira
dc.source.none.fl_str_mv Revista da Associação Médica Brasileira v.66 n.11 2020
reponame:Revista da Associação Médica Brasileira (Online)
instname:Associação Médica Brasileira (AMB)
instacron:AMB
instname_str Associação Médica Brasileira (AMB)
instacron_str AMB
institution AMB
reponame_str Revista da Associação Médica Brasileira (Online)
collection Revista da Associação Médica Brasileira (Online)
repository.name.fl_str_mv Revista da Associação Médica Brasileira (Online) - Associação Médica Brasileira (AMB)
repository.mail.fl_str_mv ||ramb@amb.org.br
_version_ 1754212835577036800