Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | São Paulo medical journal (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802003000300002 |
Resumo: | CONTEXT: The most frequently used methods for detecting antibodies are the indirect immunofluorescence test and the enzymatic immunoassay (ELISA). The polymerase chain reaction is a molecular biology technique in which the production of large amounts of specific DNA fragments is induced from very low concentrations of complex substrates aloowing the detection of very low amounts of viral particles. OBJECTIVE: To assess the accuracy of serological/ELISA tests in comparison with the polymerase chain reaction in maternal blood to diagnose cytomegalovirus infection. DESIGN: A descriptive study was performed. SETTING: High-risk outpatient clinic of Campinas University (Unicamp). PARTICIPANTS: We selected 243 pregnant women. All of them had been indicated for blood sampling because of suspicions of cytomegalovirus infection and also because of other infections. MAIN MEASUREMENTS: The group was tested for cytomegalovirus. Serological tests were run and compared to the polymerase chain reaction, which was considered to be the gold standard. Status analyses were done using Fisher's exact test, via the SAS software. RESULTS: The previous cytomegalovirus infection rate was 94.6%. The main reasons for inclusion in the study were fetal nervous system malformation (25.5%), maternal toxoplasmosis (25.5%) and Rh isoimmunization (14.8%). Only two women were included because of positive serological immunoglobulin M test for cytomegalovirus. The sensitivity and specificity of the serological tests were 94% and 6% for immunoglobulin G. CONCLUSION: Serological tests had lower sensitivity in comparison with the polymerase chain reaction test when diagnosing cytomegalovirus infection. The consequences of positive polymerase chain reaction and negative immunoglobulin M in women remain unknown. |
id |
APM-1_19b06de5e9f04525890a47b27424c4ea |
---|---|
oai_identifier_str |
oai:scielo:S1516-31802003000300002 |
network_acronym_str |
APM-1 |
network_name_str |
São Paulo medical journal (Online) |
repository_id_str |
|
spelling |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancyVirusPregnancySerologyPolymerase chain reactionCONTEXT: The most frequently used methods for detecting antibodies are the indirect immunofluorescence test and the enzymatic immunoassay (ELISA). The polymerase chain reaction is a molecular biology technique in which the production of large amounts of specific DNA fragments is induced from very low concentrations of complex substrates aloowing the detection of very low amounts of viral particles. OBJECTIVE: To assess the accuracy of serological/ELISA tests in comparison with the polymerase chain reaction in maternal blood to diagnose cytomegalovirus infection. DESIGN: A descriptive study was performed. SETTING: High-risk outpatient clinic of Campinas University (Unicamp). PARTICIPANTS: We selected 243 pregnant women. All of them had been indicated for blood sampling because of suspicions of cytomegalovirus infection and also because of other infections. MAIN MEASUREMENTS: The group was tested for cytomegalovirus. Serological tests were run and compared to the polymerase chain reaction, which was considered to be the gold standard. Status analyses were done using Fisher's exact test, via the SAS software. RESULTS: The previous cytomegalovirus infection rate was 94.6%. The main reasons for inclusion in the study were fetal nervous system malformation (25.5%), maternal toxoplasmosis (25.5%) and Rh isoimmunization (14.8%). Only two women were included because of positive serological immunoglobulin M test for cytomegalovirus. The sensitivity and specificity of the serological tests were 94% and 6% for immunoglobulin G. CONCLUSION: Serological tests had lower sensitivity in comparison with the polymerase chain reaction test when diagnosing cytomegalovirus infection. The consequences of positive polymerase chain reaction and negative immunoglobulin M in women remain unknown.Associação Paulista de Medicina - APM2003-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802003000300002Sao Paulo Medical Journal v.121 n.3 2003reponame:São Paulo medical journal (Online)instname:Associação Paulista de Medicinainstacron:APM10.1590/S1516-31802003000300002info:eu-repo/semantics/openAccessParmigiani,Silvana VarellaBarini,RicardoCosta,Sandra Cecília BotelhoAmaral,ElianaSilva,José Carlos Gama daPinto e Silva,João Luiz de Carvalhoeng2003-08-08T00:00:00Zoai:scielo:S1516-31802003000300002Revistahttp://www.scielo.br/spmjhttps://old.scielo.br/oai/scielo-oai.phprevistas@apm.org.br1806-94601516-3180opendoar:2003-08-08T00:00São Paulo medical journal (Online) - Associação Paulista de Medicinafalse |
dc.title.none.fl_str_mv |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy |
title |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy |
spellingShingle |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy Parmigiani,Silvana Varella Virus Pregnancy Serology Polymerase chain reaction |
title_short |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy |
title_full |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy |
title_fullStr |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy |
title_full_unstemmed |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy |
title_sort |
Accuracy of the serological ELISA test compared with the polymerase chain reaction for the diagnosis of cytomegalovirus infection in pregnancy |
author |
Parmigiani,Silvana Varella |
author_facet |
Parmigiani,Silvana Varella Barini,Ricardo Costa,Sandra Cecília Botelho Amaral,Eliana Silva,José Carlos Gama da Pinto e Silva,João Luiz de Carvalho |
author_role |
author |
author2 |
Barini,Ricardo Costa,Sandra Cecília Botelho Amaral,Eliana Silva,José Carlos Gama da Pinto e Silva,João Luiz de Carvalho |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Parmigiani,Silvana Varella Barini,Ricardo Costa,Sandra Cecília Botelho Amaral,Eliana Silva,José Carlos Gama da Pinto e Silva,João Luiz de Carvalho |
dc.subject.por.fl_str_mv |
Virus Pregnancy Serology Polymerase chain reaction |
topic |
Virus Pregnancy Serology Polymerase chain reaction |
description |
CONTEXT: The most frequently used methods for detecting antibodies are the indirect immunofluorescence test and the enzymatic immunoassay (ELISA). The polymerase chain reaction is a molecular biology technique in which the production of large amounts of specific DNA fragments is induced from very low concentrations of complex substrates aloowing the detection of very low amounts of viral particles. OBJECTIVE: To assess the accuracy of serological/ELISA tests in comparison with the polymerase chain reaction in maternal blood to diagnose cytomegalovirus infection. DESIGN: A descriptive study was performed. SETTING: High-risk outpatient clinic of Campinas University (Unicamp). PARTICIPANTS: We selected 243 pregnant women. All of them had been indicated for blood sampling because of suspicions of cytomegalovirus infection and also because of other infections. MAIN MEASUREMENTS: The group was tested for cytomegalovirus. Serological tests were run and compared to the polymerase chain reaction, which was considered to be the gold standard. Status analyses were done using Fisher's exact test, via the SAS software. RESULTS: The previous cytomegalovirus infection rate was 94.6%. The main reasons for inclusion in the study were fetal nervous system malformation (25.5%), maternal toxoplasmosis (25.5%) and Rh isoimmunization (14.8%). Only two women were included because of positive serological immunoglobulin M test for cytomegalovirus. The sensitivity and specificity of the serological tests were 94% and 6% for immunoglobulin G. CONCLUSION: Serological tests had lower sensitivity in comparison with the polymerase chain reaction test when diagnosing cytomegalovirus infection. The consequences of positive polymerase chain reaction and negative immunoglobulin M in women remain unknown. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802003000300002 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802003000300002 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-31802003000300002 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Paulista de Medicina - APM |
publisher.none.fl_str_mv |
Associação Paulista de Medicina - APM |
dc.source.none.fl_str_mv |
Sao Paulo Medical Journal v.121 n.3 2003 reponame:São Paulo medical journal (Online) instname:Associação Paulista de Medicina instacron:APM |
instname_str |
Associação Paulista de Medicina |
instacron_str |
APM |
institution |
APM |
reponame_str |
São Paulo medical journal (Online) |
collection |
São Paulo medical journal (Online) |
repository.name.fl_str_mv |
São Paulo medical journal (Online) - Associação Paulista de Medicina |
repository.mail.fl_str_mv |
revistas@apm.org.br |
_version_ |
1754209260517982209 |