Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?

Detalhes bibliográficos
Autor(a) principal: Ribeiro,Tarsila C.R.
Data de Publicação: 2007
Outros Autores: Kondo,Mario, Amaral,Ana Cristina C., Parise,Edson Roberto, Bragagnolo Júnior,Maurício A., Souza,Aécio Flávio Meirelles de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Infectious Diseases
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000100017
Resumo: In order to evaluate the accuracy of a urine reagent dipstick (Multistix 10SG®) to determine ascitic fluid leukocyte count, we prospectively studied 106 cirrhotic patients from April 2003 to December 2004, in two different centers (Federal University of São Paulo - UNIFESP-EPM and Federal University of Juiz de Fora - HU-UFJF) for the rapid bedside diagnosis of spontaneous bacterial peritonitis. The mean age 54 ± 12 years, there was a predominance of males (eighty-two patients, 77%), and alcohol was the most frequent etiology (43%). Forty-four percent of patients were classified as Child B and fifty-one as Child C (51%). Abdominal paracentesis was performed both in outpatient and inpatient settings and the Multistix 10SG® was tested. Eleven cases of spontaneous bacterial peritonitis were identified by means of polymorphonuclear count. If we considered the positive Multistix 10SG® result of 3 or more, the sensitivity, specificity, positive and negative predictive value were respectively 71%, 99%, 91% and 98%. With a positive reagent strip result taken as grade 2 (traces) or more, sensitivity was 86% and specificity was 96% with positive and negative predictive values of 60% and 99%, respectively. Diagnostic accuracy was 95%. We concluded that the use of a urine reagent dipstick (Multistix 10SG®) could be considered a quick, easy and cheap method for ascitic fluid cellularity determination in SBP diagnosis.
id BSID-1_4adfc66382bd30974ee739e0b54144b8
oai_identifier_str oai:scielo:S1413-86702007000100017
network_acronym_str BSID-1
network_name_str Brazilian Journal of Infectious Diseases
repository_id_str
spelling Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?Ascitic fluidrapid diagnosisdipstickbacterial peritonitisIn order to evaluate the accuracy of a urine reagent dipstick (Multistix 10SG®) to determine ascitic fluid leukocyte count, we prospectively studied 106 cirrhotic patients from April 2003 to December 2004, in two different centers (Federal University of São Paulo - UNIFESP-EPM and Federal University of Juiz de Fora - HU-UFJF) for the rapid bedside diagnosis of spontaneous bacterial peritonitis. The mean age 54 ± 12 years, there was a predominance of males (eighty-two patients, 77%), and alcohol was the most frequent etiology (43%). Forty-four percent of patients were classified as Child B and fifty-one as Child C (51%). Abdominal paracentesis was performed both in outpatient and inpatient settings and the Multistix 10SG® was tested. Eleven cases of spontaneous bacterial peritonitis were identified by means of polymorphonuclear count. If we considered the positive Multistix 10SG® result of 3 or more, the sensitivity, specificity, positive and negative predictive value were respectively 71%, 99%, 91% and 98%. With a positive reagent strip result taken as grade 2 (traces) or more, sensitivity was 86% and specificity was 96% with positive and negative predictive values of 60% and 99%, respectively. Diagnostic accuracy was 95%. We concluded that the use of a urine reagent dipstick (Multistix 10SG®) could be considered a quick, easy and cheap method for ascitic fluid cellularity determination in SBP diagnosis.Brazilian Society of Infectious Diseases2007-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000100017Brazilian Journal of Infectious Diseases v.11 n.1 2007reponame:Brazilian Journal of Infectious Diseasesinstname:Brazilian Society of Infectious Diseases (BSID)instacron:BSID10.1590/S1413-86702007000100017info:eu-repo/semantics/openAccessRibeiro,Tarsila C.R.Kondo,MarioAmaral,Ana Cristina C.Parise,Edson RobertoBragagnolo Júnior,Maurício A.Souza,Aécio Flávio Meirelles deeng2007-06-29T00:00:00Zoai:scielo:S1413-86702007000100017Revistahttps://www.bjid.org.br/https://old.scielo.br/oai/scielo-oai.phpbjid@bjid.org.br||lgoldani@ufrgs.br1678-43911413-8670opendoar:2007-06-29T00:00Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)false
dc.title.none.fl_str_mv Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
title Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
spellingShingle Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
Ribeiro,Tarsila C.R.
Ascitic fluid
rapid diagnosis
dipstick
bacterial peritonitis
title_short Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
title_full Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
title_fullStr Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
title_full_unstemmed Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
title_sort Evaluation of reagent strips for ascitic fluid leukocyte determination: is it a possible alternative for spontaneous bacterial peritonitis rapid diagnosis?
author Ribeiro,Tarsila C.R.
author_facet Ribeiro,Tarsila C.R.
Kondo,Mario
Amaral,Ana Cristina C.
Parise,Edson Roberto
Bragagnolo Júnior,Maurício A.
Souza,Aécio Flávio Meirelles de
author_role author
author2 Kondo,Mario
Amaral,Ana Cristina C.
Parise,Edson Roberto
Bragagnolo Júnior,Maurício A.
Souza,Aécio Flávio Meirelles de
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Ribeiro,Tarsila C.R.
Kondo,Mario
Amaral,Ana Cristina C.
Parise,Edson Roberto
Bragagnolo Júnior,Maurício A.
Souza,Aécio Flávio Meirelles de
dc.subject.por.fl_str_mv Ascitic fluid
rapid diagnosis
dipstick
bacterial peritonitis
topic Ascitic fluid
rapid diagnosis
dipstick
bacterial peritonitis
description In order to evaluate the accuracy of a urine reagent dipstick (Multistix 10SG®) to determine ascitic fluid leukocyte count, we prospectively studied 106 cirrhotic patients from April 2003 to December 2004, in two different centers (Federal University of São Paulo - UNIFESP-EPM and Federal University of Juiz de Fora - HU-UFJF) for the rapid bedside diagnosis of spontaneous bacterial peritonitis. The mean age 54 ± 12 years, there was a predominance of males (eighty-two patients, 77%), and alcohol was the most frequent etiology (43%). Forty-four percent of patients were classified as Child B and fifty-one as Child C (51%). Abdominal paracentesis was performed both in outpatient and inpatient settings and the Multistix 10SG® was tested. Eleven cases of spontaneous bacterial peritonitis were identified by means of polymorphonuclear count. If we considered the positive Multistix 10SG® result of 3 or more, the sensitivity, specificity, positive and negative predictive value were respectively 71%, 99%, 91% and 98%. With a positive reagent strip result taken as grade 2 (traces) or more, sensitivity was 86% and specificity was 96% with positive and negative predictive values of 60% and 99%, respectively. Diagnostic accuracy was 95%. We concluded that the use of a urine reagent dipstick (Multistix 10SG®) could be considered a quick, easy and cheap method for ascitic fluid cellularity determination in SBP diagnosis.
publishDate 2007
dc.date.none.fl_str_mv 2007-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000100017
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000100017
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1413-86702007000100017
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
dc.source.none.fl_str_mv Brazilian Journal of Infectious Diseases v.11 n.1 2007
reponame:Brazilian Journal of Infectious Diseases
instname:Brazilian Society of Infectious Diseases (BSID)
instacron:BSID
instname_str Brazilian Society of Infectious Diseases (BSID)
instacron_str BSID
institution BSID
reponame_str Brazilian Journal of Infectious Diseases
collection Brazilian Journal of Infectious Diseases
repository.name.fl_str_mv Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)
repository.mail.fl_str_mv bjid@bjid.org.br||lgoldani@ufrgs.br
_version_ 1754209239766663168