Biocide activity of microfiber mops with and without silver after contamination

Detalhes bibliográficos
Autor(a) principal: Lorenzi,Sonia De
Data de Publicação: 2011
Outros Autores: Romanini,Letizia, Finzi,Gianfranco, Salvatorelli,Germano
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Infectious Diseases
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702011000300003
Resumo: OBJECTIVE: The purpose of the present research was to compare the residual microbial load in Solo System microfiber mops with silver and in normal microfiber mops without silver to see whether those with the silver prevent bacterial proliferation and spread more effectively during normal cleaning operations. METHODS: Mops with and without silver were experimentally contaminated with suspension of Staphylococcus aureus ATCC 6538. The bioburden was evaluated by a filtering procedure according to UNI EN 1174 after contamination, after washing and after different times of impregnation in an alcohol-base detergent. RESULTS AND DISCUSSION: The results obtained lead to the conclusion that silver microfiber mop was significantly more effective in reducing bacterial load despite initial high level contamination (10(6)-10(7) CFU/50 cm²). Indeed, after low temperature washing, the bacterial load was already completely eliminated while the mop without silver still presented relatively high levels of the microorganism (approximately 10² CFU/50 cm²) even after being soaked for 8 hours in a detergent/disinfectant.
id BSID-1_5a54bcd0f68a9e1a53dfa7f3b2b13ddf
oai_identifier_str oai:scielo:S1413-86702011000300003
network_acronym_str BSID-1
network_name_str Brazilian Journal of Infectious Diseases
repository_id_str
spelling Biocide activity of microfiber mops with and without silver after contaminationdecontaminationsurface-active agentsproducts with antimicrobial actionsemi-coloninfection controlOBJECTIVE: The purpose of the present research was to compare the residual microbial load in Solo System microfiber mops with silver and in normal microfiber mops without silver to see whether those with the silver prevent bacterial proliferation and spread more effectively during normal cleaning operations. METHODS: Mops with and without silver were experimentally contaminated with suspension of Staphylococcus aureus ATCC 6538. The bioburden was evaluated by a filtering procedure according to UNI EN 1174 after contamination, after washing and after different times of impregnation in an alcohol-base detergent. RESULTS AND DISCUSSION: The results obtained lead to the conclusion that silver microfiber mop was significantly more effective in reducing bacterial load despite initial high level contamination (10(6)-10(7) CFU/50 cm²). Indeed, after low temperature washing, the bacterial load was already completely eliminated while the mop without silver still presented relatively high levels of the microorganism (approximately 10² CFU/50 cm²) even after being soaked for 8 hours in a detergent/disinfectant.Brazilian Society of Infectious Diseases2011-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702011000300003Brazilian Journal of Infectious Diseases v.15 n.3 2011reponame:Brazilian Journal of Infectious Diseasesinstname:Brazilian Society of Infectious Diseases (BSID)instacron:BSID10.1590/S1413-86702011000300003info:eu-repo/semantics/openAccessLorenzi,Sonia DeRomanini,LetiziaFinzi,GianfrancoSalvatorelli,Germanoeng2011-06-06T00:00:00Zoai:scielo:S1413-86702011000300003Revistahttps://www.bjid.org.br/https://old.scielo.br/oai/scielo-oai.phpbjid@bjid.org.br||lgoldani@ufrgs.br1678-43911413-8670opendoar:2011-06-06T00:00Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)false
dc.title.none.fl_str_mv Biocide activity of microfiber mops with and without silver after contamination
title Biocide activity of microfiber mops with and without silver after contamination
spellingShingle Biocide activity of microfiber mops with and without silver after contamination
Lorenzi,Sonia De
decontamination
surface-active agents
products with antimicrobial action
semi-colon
infection control
title_short Biocide activity of microfiber mops with and without silver after contamination
title_full Biocide activity of microfiber mops with and without silver after contamination
title_fullStr Biocide activity of microfiber mops with and without silver after contamination
title_full_unstemmed Biocide activity of microfiber mops with and without silver after contamination
title_sort Biocide activity of microfiber mops with and without silver after contamination
author Lorenzi,Sonia De
author_facet Lorenzi,Sonia De
Romanini,Letizia
Finzi,Gianfranco
Salvatorelli,Germano
author_role author
author2 Romanini,Letizia
Finzi,Gianfranco
Salvatorelli,Germano
author2_role author
author
author
dc.contributor.author.fl_str_mv Lorenzi,Sonia De
Romanini,Letizia
Finzi,Gianfranco
Salvatorelli,Germano
dc.subject.por.fl_str_mv decontamination
surface-active agents
products with antimicrobial action
semi-colon
infection control
topic decontamination
surface-active agents
products with antimicrobial action
semi-colon
infection control
description OBJECTIVE: The purpose of the present research was to compare the residual microbial load in Solo System microfiber mops with silver and in normal microfiber mops without silver to see whether those with the silver prevent bacterial proliferation and spread more effectively during normal cleaning operations. METHODS: Mops with and without silver were experimentally contaminated with suspension of Staphylococcus aureus ATCC 6538. The bioburden was evaluated by a filtering procedure according to UNI EN 1174 after contamination, after washing and after different times of impregnation in an alcohol-base detergent. RESULTS AND DISCUSSION: The results obtained lead to the conclusion that silver microfiber mop was significantly more effective in reducing bacterial load despite initial high level contamination (10(6)-10(7) CFU/50 cm²). Indeed, after low temperature washing, the bacterial load was already completely eliminated while the mop without silver still presented relatively high levels of the microorganism (approximately 10² CFU/50 cm²) even after being soaked for 8 hours in a detergent/disinfectant.
publishDate 2011
dc.date.none.fl_str_mv 2011-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702011000300003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702011000300003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1413-86702011000300003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
dc.source.none.fl_str_mv Brazilian Journal of Infectious Diseases v.15 n.3 2011
reponame:Brazilian Journal of Infectious Diseases
instname:Brazilian Society of Infectious Diseases (BSID)
instacron:BSID
instname_str Brazilian Society of Infectious Diseases (BSID)
instacron_str BSID
institution BSID
reponame_str Brazilian Journal of Infectious Diseases
collection Brazilian Journal of Infectious Diseases
repository.name.fl_str_mv Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)
repository.mail.fl_str_mv bjid@bjid.org.br||lgoldani@ufrgs.br
_version_ 1754209241598525440