Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista do Colégio Brasileiro de Cirurgiões |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912022000100211 |
Resumo: | ABSTRACT Objective: The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures. Methods: 100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems. Results: the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss’ Kappa, with no significant differences between evaluations. Only 1 of the 8 plates presented an anatomic fit greater than 70%. Long plates (8 holes) presented a poor fit compared to short plates (6 or 7 holes). Conclusions: the overall evaluation showed that currently-available pre-contoured superior plate systems provide a poor fit on clavicles for midshaft fracture fixations. Long plates present a worse fit compared to short ones. |
id |
CBC-1_8b166cdd53c64102d13b68b786eef287 |
---|---|
oai_identifier_str |
oai:scielo:S0100-69912022000100211 |
network_acronym_str |
CBC-1 |
network_name_str |
Revista do Colégio Brasileiro de Cirurgiões |
repository_id_str |
|
spelling |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systemsBone PlatesClavicleFracture Fixation, InternalABSTRACT Objective: The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures. Methods: 100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems. Results: the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss’ Kappa, with no significant differences between evaluations. Only 1 of the 8 plates presented an anatomic fit greater than 70%. Long plates (8 holes) presented a poor fit compared to short plates (6 or 7 holes). Conclusions: the overall evaluation showed that currently-available pre-contoured superior plate systems provide a poor fit on clavicles for midshaft fracture fixations. Long plates present a worse fit compared to short ones.Colégio Brasileiro de Cirurgiões2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912022000100211Revista do Colégio Brasileiro de Cirurgiões v.49 2022reponame:Revista do Colégio Brasileiro de Cirurgiõesinstname:Colégio Brasileiro de Cirurgiões (CBC)instacron:CBC10.1590/0100-6991e-20223177eninfo:eu-repo/semantics/openAccessMENDES JUNIOR,ADRIANO FERNANDOTAVARES,AUGUSTO KHEDEOPPE,IGOR GERDIPIRES,ROBINSON ESTEVESBELANGERO,WILLIAM DIASLABRONICI,PEDRO JOSÉeng2022-05-09T00:00:00Zoai:scielo:S0100-69912022000100211Revistahttp://www.scielo.br/rcbcONGhttps://old.scielo.br/oai/scielo-oai.php||revistacbc@cbc.org.br1809-45460100-6991opendoar:2022-05-09T00:00Revista do Colégio Brasileiro de Cirurgiões - Colégio Brasileiro de Cirurgiões (CBC)false |
dc.title.none.fl_str_mv |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems |
title |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems |
spellingShingle |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems MENDES JUNIOR,ADRIANO FERNANDO Bone Plates Clavicle Fracture Fixation, Internal |
title_short |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems |
title_full |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems |
title_fullStr |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems |
title_full_unstemmed |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems |
title_sort |
Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems |
author |
MENDES JUNIOR,ADRIANO FERNANDO |
author_facet |
MENDES JUNIOR,ADRIANO FERNANDO TAVARES,AUGUSTO KHEDE OPPE,IGOR GERDI PIRES,ROBINSON ESTEVES BELANGERO,WILLIAM DIAS LABRONICI,PEDRO JOSÉ |
author_role |
author |
author2 |
TAVARES,AUGUSTO KHEDE OPPE,IGOR GERDI PIRES,ROBINSON ESTEVES BELANGERO,WILLIAM DIAS LABRONICI,PEDRO JOSÉ |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
MENDES JUNIOR,ADRIANO FERNANDO TAVARES,AUGUSTO KHEDE OPPE,IGOR GERDI PIRES,ROBINSON ESTEVES BELANGERO,WILLIAM DIAS LABRONICI,PEDRO JOSÉ |
dc.subject.por.fl_str_mv |
Bone Plates Clavicle Fracture Fixation, Internal |
topic |
Bone Plates Clavicle Fracture Fixation, Internal |
description |
ABSTRACT Objective: The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures. Methods: 100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems. Results: the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss’ Kappa, with no significant differences between evaluations. Only 1 of the 8 plates presented an anatomic fit greater than 70%. Long plates (8 holes) presented a poor fit compared to short plates (6 or 7 holes). Conclusions: the overall evaluation showed that currently-available pre-contoured superior plate systems provide a poor fit on clavicles for midshaft fracture fixations. Long plates present a worse fit compared to short ones. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912022000100211 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912022000100211 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0100-6991e-20223177en |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Colégio Brasileiro de Cirurgiões |
publisher.none.fl_str_mv |
Colégio Brasileiro de Cirurgiões |
dc.source.none.fl_str_mv |
Revista do Colégio Brasileiro de Cirurgiões v.49 2022 reponame:Revista do Colégio Brasileiro de Cirurgiões instname:Colégio Brasileiro de Cirurgiões (CBC) instacron:CBC |
instname_str |
Colégio Brasileiro de Cirurgiões (CBC) |
instacron_str |
CBC |
institution |
CBC |
reponame_str |
Revista do Colégio Brasileiro de Cirurgiões |
collection |
Revista do Colégio Brasileiro de Cirurgiões |
repository.name.fl_str_mv |
Revista do Colégio Brasileiro de Cirurgiões - Colégio Brasileiro de Cirurgiões (CBC) |
repository.mail.fl_str_mv |
||revistacbc@cbc.org.br |
_version_ |
1754209215423971328 |