Clinical results in phacoemulsification using the SRK/T formula
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200011 |
Resumo: | PURPOSE: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. METHODS: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with the intraocular lens placed within the capsular bag. The same technician who was unaware of the purpose of the study made all the measurements. The achieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. RESULTS: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). CONCLUSION: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length. |
id |
CBO-2_1590c67e33b0dc78fbbd415d41d8c892 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492009000200011 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Clinical results in phacoemulsification using the SRK/T formulaBiometryCataract extractionLens implantation, Intraocular/methodsLens diseasesPhacoemulsificationRefractive errors/surgeryRefraction, ocularPURPOSE: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. METHODS: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with the intraocular lens placed within the capsular bag. The same technician who was unaware of the purpose of the study made all the measurements. The achieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. RESULTS: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). CONCLUSION: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length.Conselho Brasileiro de Oftalmologia2009-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200011Arquivos Brasileiros de Oftalmologia v.72 n.2 2009reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492009000200011info:eu-repo/semantics/openAccessLagrasta,Juliana Marques de SouzaAllemann,NormaScapucin,LucianaMoeller,Cecilia Tobias de AguiarOhkawara,Lilian EmiMelo Jr.,Luiz Alberto SoaresSoriano,Eduardo SoneCasanova,Fabio Henriqueeng2009-05-12T00:00:00Zoai:scielo:S0004-27492009000200011Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2009-05-12T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Clinical results in phacoemulsification using the SRK/T formula |
title |
Clinical results in phacoemulsification using the SRK/T formula |
spellingShingle |
Clinical results in phacoemulsification using the SRK/T formula Lagrasta,Juliana Marques de Souza Biometry Cataract extraction Lens implantation, Intraocular/methods Lens diseases Phacoemulsification Refractive errors/surgery Refraction, ocular |
title_short |
Clinical results in phacoemulsification using the SRK/T formula |
title_full |
Clinical results in phacoemulsification using the SRK/T formula |
title_fullStr |
Clinical results in phacoemulsification using the SRK/T formula |
title_full_unstemmed |
Clinical results in phacoemulsification using the SRK/T formula |
title_sort |
Clinical results in phacoemulsification using the SRK/T formula |
author |
Lagrasta,Juliana Marques de Souza |
author_facet |
Lagrasta,Juliana Marques de Souza Allemann,Norma Scapucin,Luciana Moeller,Cecilia Tobias de Aguiar Ohkawara,Lilian Emi Melo Jr.,Luiz Alberto Soares Soriano,Eduardo Sone Casanova,Fabio Henrique |
author_role |
author |
author2 |
Allemann,Norma Scapucin,Luciana Moeller,Cecilia Tobias de Aguiar Ohkawara,Lilian Emi Melo Jr.,Luiz Alberto Soares Soriano,Eduardo Sone Casanova,Fabio Henrique |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Lagrasta,Juliana Marques de Souza Allemann,Norma Scapucin,Luciana Moeller,Cecilia Tobias de Aguiar Ohkawara,Lilian Emi Melo Jr.,Luiz Alberto Soares Soriano,Eduardo Sone Casanova,Fabio Henrique |
dc.subject.por.fl_str_mv |
Biometry Cataract extraction Lens implantation, Intraocular/methods Lens diseases Phacoemulsification Refractive errors/surgery Refraction, ocular |
topic |
Biometry Cataract extraction Lens implantation, Intraocular/methods Lens diseases Phacoemulsification Refractive errors/surgery Refraction, ocular |
description |
PURPOSE: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. METHODS: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with the intraocular lens placed within the capsular bag. The same technician who was unaware of the purpose of the study made all the measurements. The achieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. RESULTS: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). CONCLUSION: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200011 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-27492009000200011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.72 n.2 2009 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209025587675136 |