Clinical results in phacoemulsification using the SRK/T formula

Detalhes bibliográficos
Autor(a) principal: Lagrasta, Juliana Marques de Souza [UNIFESP]
Data de Publicação: 2009
Outros Autores: Allemann, Norma [UNIFESP], Scapucin, Luciana [UNIFESP], Moeller, Cecilia Tobias de Aguiar [UNIFESP], Ohkawara, Lilian Emi [UNIFESP], Melo Junior, Luiz Alberto Soares [UNIFESP], Soriano, Eduardo Sone [UNIFESP], Casanova, Fabio Henrique [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0004-27492009000200011
http://repositorio.unifesp.br/handle/11600/4983
Resumo: PURPOSE: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. METHODS: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with the intraocular lens placed within the capsular bag. The same technician who was unaware of the purpose of the study made all the measurements. The achieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. RESULTS: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). CONCLUSION: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length.
id UFSP_48d2cef8ae7f2c26809f9299ccf4d31d
oai_identifier_str oai:repositorio.unifesp.br/:11600/4983
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Clinical results in phacoemulsification using the SRK/T formulaResultados clínicos na facoemulsificação utilizando a fórmula SRK/TBiometryCataract extractionLens implantation, IntraocularLens diseasesPhacoemulsificationRefractive errorsRefraction, ocularBiometriaExtração de catarataImplante de lente intraocularDoenças do cristalinoFacoemulsificaçãoErros de refraçãoRefração ocularPURPOSE: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. METHODS: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with the intraocular lens placed within the capsular bag. The same technician who was unaware of the purpose of the study made all the measurements. The achieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. RESULTS: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). CONCLUSION: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length.OBJETIVO: Avaliar resultados refracionais utilizando a fórmula SRK/T no cálculo de lentes intraoculares (LIO) em olhos com comprimento axial médio após facoemulsificação. MÉTODOS: Este estudo prospectivo envolveu 33 olhos com catarata nuclear que foram submetidos a facoemulsificação. Todas as cirurgias foram realizadas pelo mesmo cirurgião com lentes intraoculares no saco capsular. O mesmo tecnólogo, o qual não sabia o objetivo do estudo, realizou todas as medidas biométricas. O erro refracional atingido um mês após a cirurgia foi comparado ao erro refracional pós-operatório previsto pela fórmula SRK/T. RESULTADOS: O comprimento axial variou entre 22,2 mm e 24,5 mm. A refração média prevista foi -0,431 ± 0,181 dioptrias (D) e o equivalente esférico pós-operatório alcançado foi -0,220 ± 0,732 D. Dezoito olhos (55%) obtiveram erro refracional de ± 0,50 D e 30 olhos (91%) entre ± 1,00 D da refração prevista. Houve tendência a um erro hipermetrópico (média±SD: 0,211 ± 0,708 D, p=0,009). CONCLUSÃO: A fórmula SRK/T demonstrou acurácia satisfatória no cálculo do erro refracional em olhos de comprimento axial médio.Universidade Federal de São Paulo (UNIFESP) Department of OphthalmologyUniversidade Federal de São Paulo (UNIFESP) Department of OphthalmologyUNIFESP, Department of OphthalmologyUNIFESP, Department of OphthalmologySciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Lagrasta, Juliana Marques de Souza [UNIFESP]Allemann, Norma [UNIFESP]Scapucin, Luciana [UNIFESP]Moeller, Cecilia Tobias de Aguiar [UNIFESP]Ohkawara, Lilian Emi [UNIFESP]Melo Junior, Luiz Alberto Soares [UNIFESP]Soriano, Eduardo Sone [UNIFESP]Casanova, Fabio Henrique [UNIFESP]2015-06-14T13:39:10Z2015-06-14T13:39:10Z2009-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion189-193application/pdfhttp://dx.doi.org/10.1590/S0004-27492009000200011Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 72, n. 2, p. 189-193, 2009.10.1590/S0004-27492009000200011S0004-27492009000200011.pdf0004-2749S0004-27492009000200011http://repositorio.unifesp.br/handle/11600/4983WOS:000274753900011engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-04T22:12:12Zoai:repositorio.unifesp.br/:11600/4983Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-04T22:12:12Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Clinical results in phacoemulsification using the SRK/T formula
Resultados clínicos na facoemulsificação utilizando a fórmula SRK/T
title Clinical results in phacoemulsification using the SRK/T formula
spellingShingle Clinical results in phacoemulsification using the SRK/T formula
Lagrasta, Juliana Marques de Souza [UNIFESP]
Biometry
Cataract extraction
Lens implantation, Intraocular
Lens diseases
Phacoemulsification
Refractive errors
Refraction, ocular
Biometria
Extração de catarata
Implante de lente intraocular
Doenças do cristalino
Facoemulsificação
Erros de refração
Refração ocular
title_short Clinical results in phacoemulsification using the SRK/T formula
title_full Clinical results in phacoemulsification using the SRK/T formula
title_fullStr Clinical results in phacoemulsification using the SRK/T formula
title_full_unstemmed Clinical results in phacoemulsification using the SRK/T formula
title_sort Clinical results in phacoemulsification using the SRK/T formula
author Lagrasta, Juliana Marques de Souza [UNIFESP]
author_facet Lagrasta, Juliana Marques de Souza [UNIFESP]
Allemann, Norma [UNIFESP]
Scapucin, Luciana [UNIFESP]
Moeller, Cecilia Tobias de Aguiar [UNIFESP]
Ohkawara, Lilian Emi [UNIFESP]
Melo Junior, Luiz Alberto Soares [UNIFESP]
Soriano, Eduardo Sone [UNIFESP]
Casanova, Fabio Henrique [UNIFESP]
author_role author
author2 Allemann, Norma [UNIFESP]
Scapucin, Luciana [UNIFESP]
Moeller, Cecilia Tobias de Aguiar [UNIFESP]
Ohkawara, Lilian Emi [UNIFESP]
Melo Junior, Luiz Alberto Soares [UNIFESP]
Soriano, Eduardo Sone [UNIFESP]
Casanova, Fabio Henrique [UNIFESP]
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Lagrasta, Juliana Marques de Souza [UNIFESP]
Allemann, Norma [UNIFESP]
Scapucin, Luciana [UNIFESP]
Moeller, Cecilia Tobias de Aguiar [UNIFESP]
Ohkawara, Lilian Emi [UNIFESP]
Melo Junior, Luiz Alberto Soares [UNIFESP]
Soriano, Eduardo Sone [UNIFESP]
Casanova, Fabio Henrique [UNIFESP]
dc.subject.por.fl_str_mv Biometry
Cataract extraction
Lens implantation, Intraocular
Lens diseases
Phacoemulsification
Refractive errors
Refraction, ocular
Biometria
Extração de catarata
Implante de lente intraocular
Doenças do cristalino
Facoemulsificação
Erros de refração
Refração ocular
topic Biometry
Cataract extraction
Lens implantation, Intraocular
Lens diseases
Phacoemulsification
Refractive errors
Refraction, ocular
Biometria
Extração de catarata
Implante de lente intraocular
Doenças do cristalino
Facoemulsificação
Erros de refração
Refração ocular
description PURPOSE: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. METHODS: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with the intraocular lens placed within the capsular bag. The same technician who was unaware of the purpose of the study made all the measurements. The achieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. RESULTS: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). CONCLUSION: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length.
publishDate 2009
dc.date.none.fl_str_mv 2009-04-01
2015-06-14T13:39:10Z
2015-06-14T13:39:10Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0004-27492009000200011
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 72, n. 2, p. 189-193, 2009.
10.1590/S0004-27492009000200011
S0004-27492009000200011.pdf
0004-2749
S0004-27492009000200011
http://repositorio.unifesp.br/handle/11600/4983
WOS:000274753900011
url http://dx.doi.org/10.1590/S0004-27492009000200011
http://repositorio.unifesp.br/handle/11600/4983
identifier_str_mv Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 72, n. 2, p. 189-193, 2009.
10.1590/S0004-27492009000200011
S0004-27492009000200011.pdf
0004-2749
S0004-27492009000200011
WOS:000274753900011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Arquivos Brasileiros de Oftalmologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 189-193
application/pdf
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268281136087040