Resumo: PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.
id CBO-2_29fe9b21bece0e4c6bd68fd54d921a5d
oai_identifier_str oai:scielo:S0004-27492010000400003
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Simulated cup/disc ratio: a tool for ophthalmologistsOptic discGlaucoma/diagnosisOptic nerve diseases/diagnosisDiagnostic techniques, ophthalmologicalInternet/utilizationMeasuresPURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.Conselho Brasileiro de Oftalmologia2010-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000400003Arquivos Brasileiros de Oftalmologia v.73 n.4 2010reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492010000400003info:eu-repo/semantics/openAccessBarbosa,Carolina PelegriniAngelini,Pedro FelipeSchor,PauloParanhos Junior,Augustoeng2010-10-04T00:00:00Zoai:scielo:S0004-27492010000400003Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2010-10-04T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Simulated cup/disc ratio: a tool for ophthalmologists
title Simulated cup/disc ratio: a tool for ophthalmologists
spellingShingle Simulated cup/disc ratio: a tool for ophthalmologists
Barbosa,Carolina Pelegrini
Optic disc
Glaucoma/diagnosis
Optic nerve diseases/diagnosis
Diagnostic techniques, ophthalmological
Internet/utilization
Measures
title_short Simulated cup/disc ratio: a tool for ophthalmologists
title_full Simulated cup/disc ratio: a tool for ophthalmologists
title_fullStr Simulated cup/disc ratio: a tool for ophthalmologists
title_full_unstemmed Simulated cup/disc ratio: a tool for ophthalmologists
title_sort Simulated cup/disc ratio: a tool for ophthalmologists
author Barbosa,Carolina Pelegrini
author_facet Barbosa,Carolina Pelegrini
Angelini,Pedro Felipe
Schor,Paulo
Paranhos Junior,Augusto
author_role author
author2 Angelini,Pedro Felipe
Schor,Paulo
Paranhos Junior,Augusto
author2_role author
author
author
dc.contributor.author.fl_str_mv Barbosa,Carolina Pelegrini
Angelini,Pedro Felipe
Schor,Paulo
Paranhos Junior,Augusto
dc.subject.por.fl_str_mv Optic disc
Glaucoma/diagnosis
Optic nerve diseases/diagnosis
Diagnostic techniques, ophthalmological
Internet/utilization
Measures
topic Optic disc
Glaucoma/diagnosis
Optic nerve diseases/diagnosis
Diagnostic techniques, ophthalmological
Internet/utilization
Measures
description PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.
publishDate 2010
dc.date.none.fl_str_mv 2010-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000400003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492010000400003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27492010000400003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.73 n.4 2010
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209026423390208