Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography

Detalhes bibliográficos
Autor(a) principal: Ribeiro Jr.,Valdenir
Data de Publicação: 2017
Outros Autores: Ribeiro,Cristiane Farias, Ávila,Marcos P., Magacho,Leopoldo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386
Resumo: ABSTRACT Purpose: To compare the linear measurements of the optic disk cup obtained using RTVue optical coherence tomography (OCT) with those obtained using digital retinography. Methods: This is a cross-sectional study performed with digital retinography and RTVue OCT images from patients with glaucoma or patients suspected of glaucoma. In color retinography, the greatest horizontal and vertical diameters of the optic disk starting from the inner edge of the Elschnig ring were obtained using a pachymeter with a grade of 0.01 mm. In OCT, the delineation of the optic nerve was obtained automatically from the horizontal and vertical cup results. Results: One hundred eyes from 100 subjects with a mean age of 60.1 ± 15.7 years were included. Of these, 79 were the right eye and 21 the left eye, with 61 men and 39 women. The mean horizontal cup obtained with OCT was 0.91 ± 0.10, while that obtained with retinography was 0.79 ± 0.11 (p<0.01). Conclusions: There was poor agreement between the evaluated methods in the measurements of optic disk cup excavations. Measurements obtained automatically with OCT RTVue were higher but were significantly correlated with measurements obtained manually with digital retinography. Poor agreement of the optic disk parameters between the two imaging devices was noted.
id CBO-2_a732a563b9ced0965c91e99b8a409f04
oai_identifier_str oai:scielo:S0004-27492017000600386
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinographyOptic diskGlaucoma/diagnosisOptic nerveAqueous humorTomographyOptical coherenceDiagnostic techniquesOphthalmologicalABSTRACT Purpose: To compare the linear measurements of the optic disk cup obtained using RTVue optical coherence tomography (OCT) with those obtained using digital retinography. Methods: This is a cross-sectional study performed with digital retinography and RTVue OCT images from patients with glaucoma or patients suspected of glaucoma. In color retinography, the greatest horizontal and vertical diameters of the optic disk starting from the inner edge of the Elschnig ring were obtained using a pachymeter with a grade of 0.01 mm. In OCT, the delineation of the optic nerve was obtained automatically from the horizontal and vertical cup results. Results: One hundred eyes from 100 subjects with a mean age of 60.1 ± 15.7 years were included. Of these, 79 were the right eye and 21 the left eye, with 61 men and 39 women. The mean horizontal cup obtained with OCT was 0.91 ± 0.10, while that obtained with retinography was 0.79 ± 0.11 (p<0.01). Conclusions: There was poor agreement between the evaluated methods in the measurements of optic disk cup excavations. Measurements obtained automatically with OCT RTVue were higher but were significantly correlated with measurements obtained manually with digital retinography. Poor agreement of the optic disk parameters between the two imaging devices was noted.Conselho Brasileiro de Oftalmologia2017-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386Arquivos Brasileiros de Oftalmologia v.80 n.6 2017reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20170094info:eu-repo/semantics/openAccessRibeiro Jr.,ValdenirRibeiro,Cristiane FariasÁvila,Marcos P.Magacho,Leopoldoeng2017-12-11T00:00:00Zoai:scielo:S0004-27492017000600386Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2017-12-11T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
title Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
spellingShingle Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
Ribeiro Jr.,Valdenir
Optic disk
Glaucoma/diagnosis
Optic nerve
Aqueous humor
Tomography
Optical coherence
Diagnostic techniques
Ophthalmological
title_short Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
title_full Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
title_fullStr Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
title_full_unstemmed Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
title_sort Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
author Ribeiro Jr.,Valdenir
author_facet Ribeiro Jr.,Valdenir
Ribeiro,Cristiane Farias
Ávila,Marcos P.
Magacho,Leopoldo
author_role author
author2 Ribeiro,Cristiane Farias
Ávila,Marcos P.
Magacho,Leopoldo
author2_role author
author
author
dc.contributor.author.fl_str_mv Ribeiro Jr.,Valdenir
Ribeiro,Cristiane Farias
Ávila,Marcos P.
Magacho,Leopoldo
dc.subject.por.fl_str_mv Optic disk
Glaucoma/diagnosis
Optic nerve
Aqueous humor
Tomography
Optical coherence
Diagnostic techniques
Ophthalmological
topic Optic disk
Glaucoma/diagnosis
Optic nerve
Aqueous humor
Tomography
Optical coherence
Diagnostic techniques
Ophthalmological
description ABSTRACT Purpose: To compare the linear measurements of the optic disk cup obtained using RTVue optical coherence tomography (OCT) with those obtained using digital retinography. Methods: This is a cross-sectional study performed with digital retinography and RTVue OCT images from patients with glaucoma or patients suspected of glaucoma. In color retinography, the greatest horizontal and vertical diameters of the optic disk starting from the inner edge of the Elschnig ring were obtained using a pachymeter with a grade of 0.01 mm. In OCT, the delineation of the optic nerve was obtained automatically from the horizontal and vertical cup results. Results: One hundred eyes from 100 subjects with a mean age of 60.1 ± 15.7 years were included. Of these, 79 were the right eye and 21 the left eye, with 61 men and 39 women. The mean horizontal cup obtained with OCT was 0.91 ± 0.10, while that obtained with retinography was 0.79 ± 0.11 (p<0.01). Conclusions: There was poor agreement between the evaluated methods in the measurements of optic disk cup excavations. Measurements obtained automatically with OCT RTVue were higher but were significantly correlated with measurements obtained manually with digital retinography. Poor agreement of the optic disk parameters between the two imaging devices was noted.
publishDate 2017
dc.date.none.fl_str_mv 2017-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20170094
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.80 n.6 2017
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209029529272320