Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386 |
Resumo: | ABSTRACT Purpose: To compare the linear measurements of the optic disk cup obtained using RTVue optical coherence tomography (OCT) with those obtained using digital retinography. Methods: This is a cross-sectional study performed with digital retinography and RTVue OCT images from patients with glaucoma or patients suspected of glaucoma. In color retinography, the greatest horizontal and vertical diameters of the optic disk starting from the inner edge of the Elschnig ring were obtained using a pachymeter with a grade of 0.01 mm. In OCT, the delineation of the optic nerve was obtained automatically from the horizontal and vertical cup results. Results: One hundred eyes from 100 subjects with a mean age of 60.1 ± 15.7 years were included. Of these, 79 were the right eye and 21 the left eye, with 61 men and 39 women. The mean horizontal cup obtained with OCT was 0.91 ± 0.10, while that obtained with retinography was 0.79 ± 0.11 (p<0.01). Conclusions: There was poor agreement between the evaluated methods in the measurements of optic disk cup excavations. Measurements obtained automatically with OCT RTVue were higher but were significantly correlated with measurements obtained manually with digital retinography. Poor agreement of the optic disk parameters between the two imaging devices was noted. |
id |
CBO-2_a732a563b9ced0965c91e99b8a409f04 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492017000600386 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinographyOptic diskGlaucoma/diagnosisOptic nerveAqueous humorTomographyOptical coherenceDiagnostic techniquesOphthalmologicalABSTRACT Purpose: To compare the linear measurements of the optic disk cup obtained using RTVue optical coherence tomography (OCT) with those obtained using digital retinography. Methods: This is a cross-sectional study performed with digital retinography and RTVue OCT images from patients with glaucoma or patients suspected of glaucoma. In color retinography, the greatest horizontal and vertical diameters of the optic disk starting from the inner edge of the Elschnig ring were obtained using a pachymeter with a grade of 0.01 mm. In OCT, the delineation of the optic nerve was obtained automatically from the horizontal and vertical cup results. Results: One hundred eyes from 100 subjects with a mean age of 60.1 ± 15.7 years were included. Of these, 79 were the right eye and 21 the left eye, with 61 men and 39 women. The mean horizontal cup obtained with OCT was 0.91 ± 0.10, while that obtained with retinography was 0.79 ± 0.11 (p<0.01). Conclusions: There was poor agreement between the evaluated methods in the measurements of optic disk cup excavations. Measurements obtained automatically with OCT RTVue were higher but were significantly correlated with measurements obtained manually with digital retinography. Poor agreement of the optic disk parameters between the two imaging devices was noted.Conselho Brasileiro de Oftalmologia2017-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386Arquivos Brasileiros de Oftalmologia v.80 n.6 2017reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20170094info:eu-repo/semantics/openAccessRibeiro Jr.,ValdenirRibeiro,Cristiane FariasÁvila,Marcos P.Magacho,Leopoldoeng2017-12-11T00:00:00Zoai:scielo:S0004-27492017000600386Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2017-12-11T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography |
title |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography |
spellingShingle |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography Ribeiro Jr.,Valdenir Optic disk Glaucoma/diagnosis Optic nerve Aqueous humor Tomography Optical coherence Diagnostic techniques Ophthalmological |
title_short |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography |
title_full |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography |
title_fullStr |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography |
title_full_unstemmed |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography |
title_sort |
Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography |
author |
Ribeiro Jr.,Valdenir |
author_facet |
Ribeiro Jr.,Valdenir Ribeiro,Cristiane Farias Ávila,Marcos P. Magacho,Leopoldo |
author_role |
author |
author2 |
Ribeiro,Cristiane Farias Ávila,Marcos P. Magacho,Leopoldo |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Ribeiro Jr.,Valdenir Ribeiro,Cristiane Farias Ávila,Marcos P. Magacho,Leopoldo |
dc.subject.por.fl_str_mv |
Optic disk Glaucoma/diagnosis Optic nerve Aqueous humor Tomography Optical coherence Diagnostic techniques Ophthalmological |
topic |
Optic disk Glaucoma/diagnosis Optic nerve Aqueous humor Tomography Optical coherence Diagnostic techniques Ophthalmological |
description |
ABSTRACT Purpose: To compare the linear measurements of the optic disk cup obtained using RTVue optical coherence tomography (OCT) with those obtained using digital retinography. Methods: This is a cross-sectional study performed with digital retinography and RTVue OCT images from patients with glaucoma or patients suspected of glaucoma. In color retinography, the greatest horizontal and vertical diameters of the optic disk starting from the inner edge of the Elschnig ring were obtained using a pachymeter with a grade of 0.01 mm. In OCT, the delineation of the optic nerve was obtained automatically from the horizontal and vertical cup results. Results: One hundred eyes from 100 subjects with a mean age of 60.1 ± 15.7 years were included. Of these, 79 were the right eye and 21 the left eye, with 61 men and 39 women. The mean horizontal cup obtained with OCT was 0.91 ± 0.10, while that obtained with retinography was 0.79 ± 0.11 (p<0.01). Conclusions: There was poor agreement between the evaluated methods in the measurements of optic disk cup excavations. Measurements obtained automatically with OCT RTVue were higher but were significantly correlated with measurements obtained manually with digital retinography. Poor agreement of the optic disk parameters between the two imaging devices was noted. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000600386 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20170094 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.80 n.6 2017 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209029529272320 |