Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis

Detalhes bibliográficos
Autor(a) principal: Machado,Marco Antonio de Campos
Data de Publicação: 2017
Outros Autores: Silva,João Amaro Ferrari, Garcia,Eduardo Alonso, Allemann,Norma
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172
Resumo: ABSTRACT Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.
id CBO-2_4c65d824f885e42c73fce4f7f4f060c9
oai_identifier_str oai:scielo:S0004-27492017000300172
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Ultrasound parameters of normal lacrimal sac and chronic dacryocystitisLacrimal apparatus, ultrasonographyLacrimal duct obstructionDacryocystitisABSTRACT Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.Conselho Brasileiro de Oftalmologia2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172Arquivos Brasileiros de Oftalmologia v.80 n.3 2017reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20170042info:eu-repo/semantics/openAccessMachado,Marco Antonio de CamposSilva,João Amaro FerrariGarcia,Eduardo AlonsoAllemann,Normaeng2017-08-14T00:00:00Zoai:scielo:S0004-27492017000300172Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2017-08-14T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
spellingShingle Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
Machado,Marco Antonio de Campos
Lacrimal apparatus, ultrasonography
Lacrimal duct obstruction
Dacryocystitis
title_short Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_full Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_fullStr Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_full_unstemmed Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_sort Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
author Machado,Marco Antonio de Campos
author_facet Machado,Marco Antonio de Campos
Silva,João Amaro Ferrari
Garcia,Eduardo Alonso
Allemann,Norma
author_role author
author2 Silva,João Amaro Ferrari
Garcia,Eduardo Alonso
Allemann,Norma
author2_role author
author
author
dc.contributor.author.fl_str_mv Machado,Marco Antonio de Campos
Silva,João Amaro Ferrari
Garcia,Eduardo Alonso
Allemann,Norma
dc.subject.por.fl_str_mv Lacrimal apparatus, ultrasonography
Lacrimal duct obstruction
Dacryocystitis
topic Lacrimal apparatus, ultrasonography
Lacrimal duct obstruction
Dacryocystitis
description ABSTRACT Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.
publishDate 2017
dc.date.none.fl_str_mv 2017-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20170042
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.80 n.3 2017
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209029445386240