Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172 |
Resumo: | ABSTRACT Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning. |
id |
CBO-2_4c65d824f885e42c73fce4f7f4f060c9 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492017000300172 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitisLacrimal apparatus, ultrasonographyLacrimal duct obstructionDacryocystitisABSTRACT Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.Conselho Brasileiro de Oftalmologia2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172Arquivos Brasileiros de Oftalmologia v.80 n.3 2017reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20170042info:eu-repo/semantics/openAccessMachado,Marco Antonio de CamposSilva,João Amaro FerrariGarcia,Eduardo AlonsoAllemann,Normaeng2017-08-14T00:00:00Zoai:scielo:S0004-27492017000300172Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2017-08-14T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis |
title |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis |
spellingShingle |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis Machado,Marco Antonio de Campos Lacrimal apparatus, ultrasonography Lacrimal duct obstruction Dacryocystitis |
title_short |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis |
title_full |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis |
title_fullStr |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis |
title_full_unstemmed |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis |
title_sort |
Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis |
author |
Machado,Marco Antonio de Campos |
author_facet |
Machado,Marco Antonio de Campos Silva,João Amaro Ferrari Garcia,Eduardo Alonso Allemann,Norma |
author_role |
author |
author2 |
Silva,João Amaro Ferrari Garcia,Eduardo Alonso Allemann,Norma |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Machado,Marco Antonio de Campos Silva,João Amaro Ferrari Garcia,Eduardo Alonso Allemann,Norma |
dc.subject.por.fl_str_mv |
Lacrimal apparatus, ultrasonography Lacrimal duct obstruction Dacryocystitis |
topic |
Lacrimal apparatus, ultrasonography Lacrimal duct obstruction Dacryocystitis |
description |
ABSTRACT Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20170042 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.80 n.3 2017 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209029445386240 |