Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis

Detalhes bibliográficos
Autor(a) principal: Machado, Marco Antonio de Campos [UNIFESP]
Data de Publicação: 2017
Outros Autores: Silva, João Amaro Ferrari [UNIFESP], Garcia, Eduardo Alonso [UNIFESP], Allemann, Norma [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172
https://repositorio.unifesp.br/handle/11600/54507
Resumo: Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.
id UFSP_4ecf7fdeefc91bd70ce9a09d4a69a8dd
oai_identifier_str oai:repositorio.unifesp.br/:11600/54507
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Ultrasound parameters of normal lacrimal sac and chronic dacryocystitisParâmetros ultrassonográficos do saco lacrimal normal e na dacriocistite crônicaLacrimal apparatusUltrasonographyLacrimal duct obstructionDacryocystitisAparelho lacrimal/ultrassonografiaObstrução dos ductos lacrimaisDacriocistitePurpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.Objetivo: Categorizar os achados ultrassonográficos do saco lacrimal em indivíduos com via lacrimal normal e em portadores de dacriocistite crônica. Métodos: Estudo retrospectivo de 20 indivíduos, 10 com via lacrimal normal (Grupo 1) e 10 com diagnóstico de dacriocistite crônica (Grupo 2) utilizando ultrassonografia modo B com transdutor de 10 MHz e técnica de contato (Aviso, Quantel Medical) para avaliar o saco lacrimal. Analisamos os seguintes parâmetros: dimensões, características e conteúdo. Resultados: Características da população estudada: sexo feminino: 6, Grupo 1; 8, Grupo 2; idade média: 48,4 anos (DP=19,93; variação, 22 a 80 anos), Grupo 1; 50,5 anos (DP=15,47; variação, 25 a 75 anos), Grupo 2. As dimensões do saco lacrimal foram aferidas: anteroposterior, 1,86 mm no Grupo 1 e 10,99 mm no Grupo 2, p<0,0001; vertical, 9,79 mm no Grupo 1 e 14,13 mm no Grupo 2, p=0,049. A avaliação qualitativa do conteúdo do saco lacrimal mostrou: conteúdo hipoecogênico no Grupo 1 (10, 100%); e conteúdo puntiforme hiperecogênico no Grupo 2 (10, 100%), com preenchimento parcial em 7 casos (70%). Conclusão: A ultrassonografia foi capaz de diferenciar a via lacrimal normal da acometida por dacriocistite crônica, e de determinar parâmetros úteis para suportar o acompanhamento clínico ou auxiliar no planejamento cirúrgico.Univ Fed Sao Paulo, Escola Paulista Med, Dept Ophthalmol, Sao Paulo, SP, BrazilUniv Fed Sao Paulo, Escola Paulista Med, Dept Ophthalmol, Sao Paulo, SP, BrazilWeb of ScienceConsel Brasil OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Machado, Marco Antonio de Campos [UNIFESP]Silva, João Amaro Ferrari [UNIFESP]Garcia, Eduardo Alonso [UNIFESP]Allemann, Norma [UNIFESP]2020-07-13T11:53:17Z2020-07-13T11:53:17Z2017info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion172-175application/pdfhttps://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172Arquivos Brasileiros De Oftalmologia. Sao Paulo, v. 80, n. 3, p. 172-175, 2017.10.5935/0004-2749.20170042S0004-27492017000300172.pdf0004-2749S0004-27492017000300172https://repositorio.unifesp.br/handle/11600/54507WOS:000408254100008engArquivos Brasileiros De OftalmologiaSao Pauloinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-01T09:00:27Zoai:repositorio.unifesp.br/:11600/54507Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-01T09:00:27Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
Parâmetros ultrassonográficos do saco lacrimal normal e na dacriocistite crônica
title Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
spellingShingle Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
Machado, Marco Antonio de Campos [UNIFESP]
Lacrimal apparatus
Ultrasonography
Lacrimal duct obstruction
Dacryocystitis
Aparelho lacrimal/ultrassonografia
Obstrução dos ductos lacrimais
Dacriocistite
title_short Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_full Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_fullStr Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_full_unstemmed Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
title_sort Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis
author Machado, Marco Antonio de Campos [UNIFESP]
author_facet Machado, Marco Antonio de Campos [UNIFESP]
Silva, João Amaro Ferrari [UNIFESP]
Garcia, Eduardo Alonso [UNIFESP]
Allemann, Norma [UNIFESP]
author_role author
author2 Silva, João Amaro Ferrari [UNIFESP]
Garcia, Eduardo Alonso [UNIFESP]
Allemann, Norma [UNIFESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Machado, Marco Antonio de Campos [UNIFESP]
Silva, João Amaro Ferrari [UNIFESP]
Garcia, Eduardo Alonso [UNIFESP]
Allemann, Norma [UNIFESP]
dc.subject.por.fl_str_mv Lacrimal apparatus
Ultrasonography
Lacrimal duct obstruction
Dacryocystitis
Aparelho lacrimal/ultrassonografia
Obstrução dos ductos lacrimais
Dacriocistite
topic Lacrimal apparatus
Ultrasonography
Lacrimal duct obstruction
Dacryocystitis
Aparelho lacrimal/ultrassonografia
Obstrução dos ductos lacrimais
Dacriocistite
description Purpose: To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. Methods: A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. Results: The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Conclusions: Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.
publishDate 2017
dc.date.none.fl_str_mv 2017
2020-07-13T11:53:17Z
2020-07-13T11:53:17Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172
Arquivos Brasileiros De Oftalmologia. Sao Paulo, v. 80, n. 3, p. 172-175, 2017.
10.5935/0004-2749.20170042
S0004-27492017000300172.pdf
0004-2749
S0004-27492017000300172
https://repositorio.unifesp.br/handle/11600/54507
WOS:000408254100008
url https://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000300172
https://repositorio.unifesp.br/handle/11600/54507
identifier_str_mv Arquivos Brasileiros De Oftalmologia. Sao Paulo, v. 80, n. 3, p. 172-175, 2017.
10.5935/0004-2749.20170042
S0004-27492017000300172.pdf
0004-2749
S0004-27492017000300172
WOS:000408254100008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Arquivos Brasileiros De Oftalmologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 172-175
application/pdf
dc.coverage.none.fl_str_mv Sao Paulo
dc.publisher.none.fl_str_mv Consel Brasil Oftalmologia
publisher.none.fl_str_mv Consel Brasil Oftalmologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268330071031808