Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000200129 |
Resumo: | ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significant changes in axial length, central corneal thickness, anterior chamber depth, and keratometric measurements with soft contact lenses as compared to the naked eye (p<0.001). However, there were no significant differences in lens thickness outcomes between the naked eye and while wearing the three soft contact lenses (p>0.5). The changes in axial length, central corneal thickness, and anterior chamber depth were lens-specific and dependent on the thickness of the lens used. Conclusions: Sept-source optical coherence tomography based lens thickness measurements while wearing soft contact lenses are comparable to those of the naked eye. However, the thickness and the optical design of the soft contact lens may lead to significant differences in the axial lengh, central corneal thickness, anterior chamber deph, and keratometric measurements. |
id |
CBO-2_5d3dc0c23f0348888ae2ffd738151b74 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492019000200129 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomographyTomography, optical coherenceContact lensesBiometryABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significant changes in axial length, central corneal thickness, anterior chamber depth, and keratometric measurements with soft contact lenses as compared to the naked eye (p<0.001). However, there were no significant differences in lens thickness outcomes between the naked eye and while wearing the three soft contact lenses (p>0.5). The changes in axial length, central corneal thickness, and anterior chamber depth were lens-specific and dependent on the thickness of the lens used. Conclusions: Sept-source optical coherence tomography based lens thickness measurements while wearing soft contact lenses are comparable to those of the naked eye. However, the thickness and the optical design of the soft contact lens may lead to significant differences in the axial lengh, central corneal thickness, anterior chamber deph, and keratometric measurements.Conselho Brasileiro de Oftalmologia2019-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000200129Arquivos Brasileiros de Oftalmologia v.82 n.2 2019reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20190020info:eu-repo/semantics/openAccessFerrer-Blasco,TeresaEsteve-Taboada,José J.Domínguez-Vicent,AlbertoAloy,Miguel A.Adsuara,José E.Mimica,PetarMontés-Micó,Roberteng2019-01-31T00:00:00Zoai:scielo:S0004-27492019000200129Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2019-01-31T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography |
title |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography |
spellingShingle |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography Ferrer-Blasco,Teresa Tomography, optical coherence Contact lenses Biometry |
title_short |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography |
title_full |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography |
title_fullStr |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography |
title_full_unstemmed |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography |
title_sort |
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography |
author |
Ferrer-Blasco,Teresa |
author_facet |
Ferrer-Blasco,Teresa Esteve-Taboada,José J. Domínguez-Vicent,Alberto Aloy,Miguel A. Adsuara,José E. Mimica,Petar Montés-Micó,Robert |
author_role |
author |
author2 |
Esteve-Taboada,José J. Domínguez-Vicent,Alberto Aloy,Miguel A. Adsuara,José E. Mimica,Petar Montés-Micó,Robert |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Ferrer-Blasco,Teresa Esteve-Taboada,José J. Domínguez-Vicent,Alberto Aloy,Miguel A. Adsuara,José E. Mimica,Petar Montés-Micó,Robert |
dc.subject.por.fl_str_mv |
Tomography, optical coherence Contact lenses Biometry |
topic |
Tomography, optical coherence Contact lenses Biometry |
description |
ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significant changes in axial length, central corneal thickness, anterior chamber depth, and keratometric measurements with soft contact lenses as compared to the naked eye (p<0.001). However, there were no significant differences in lens thickness outcomes between the naked eye and while wearing the three soft contact lenses (p>0.5). The changes in axial length, central corneal thickness, and anterior chamber depth were lens-specific and dependent on the thickness of the lens used. Conclusions: Sept-source optical coherence tomography based lens thickness measurements while wearing soft contact lenses are comparable to those of the naked eye. However, the thickness and the optical design of the soft contact lens may lead to significant differences in the axial lengh, central corneal thickness, anterior chamber deph, and keratometric measurements. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000200129 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000200129 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20190020 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.82 n.2 2019 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209030353453056 |