Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400228 |
Resumo: | Purpose: To investigate the effects of topically applied 1% cyclopentolate hydrochloride on anterior segment parameters obtained with a Pentacam rotating Scheimpflug camera in healthy young adults. Methods: Anterior segment analyses of 25 eyes from 25 young adults (Group 1), before and after 45 min of 1% cyclopentolate hydrochloride application, were performed. For a control group (cycloplegia-free, Group 2), 24 eyes of 24 age- and sex-matched healthy cases were evaluated twice at 45 min intervals. The results obtained from the groups were compared statistically. Results: The mean ages of the groups were 23.04 ± 3.42 (range, 18-29) and 22.4 ± 2.05 (range, 18-27) years for Groups 1 and 2, respectively (p=0.259). In Group 1, measurements between the two analyses were significantly different for the values of anterior chamber depth (ACD), anterior chamber angle (ACA), and anterior chamber volume (ACV) (p<0.05), whereas no statistical difference was found for the central corneal thickness (CCT) and keratometry (K1, K2) measurements. In Group 2, none of these parameters were statistically different between the two analyses. Conclusions: Topically applied 1% cyclopentolate hydrochloride caused an increase in the ACD and ACV values, and a decrease in the ACA value. However, it had no significant effect on the CCT and keratometry measurements. It is important to consider these effects when using the Pentacam device on young adults with cycloplegia and when applying it for various reasons. |
id |
CBO-2_6339a6dd83de10d9282b253654b02fa8 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492014000400228 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adultsBiometryCorneaCorneal pachymetryCyclopentolate/administration and dosageTechniques, measures, measurement equipment Purpose: To investigate the effects of topically applied 1% cyclopentolate hydrochloride on anterior segment parameters obtained with a Pentacam rotating Scheimpflug camera in healthy young adults. Methods: Anterior segment analyses of 25 eyes from 25 young adults (Group 1), before and after 45 min of 1% cyclopentolate hydrochloride application, were performed. For a control group (cycloplegia-free, Group 2), 24 eyes of 24 age- and sex-matched healthy cases were evaluated twice at 45 min intervals. The results obtained from the groups were compared statistically. Results: The mean ages of the groups were 23.04 ± 3.42 (range, 18-29) and 22.4 ± 2.05 (range, 18-27) years for Groups 1 and 2, respectively (p=0.259). In Group 1, measurements between the two analyses were significantly different for the values of anterior chamber depth (ACD), anterior chamber angle (ACA), and anterior chamber volume (ACV) (p<0.05), whereas no statistical difference was found for the central corneal thickness (CCT) and keratometry (K1, K2) measurements. In Group 2, none of these parameters were statistically different between the two analyses. Conclusions: Topically applied 1% cyclopentolate hydrochloride caused an increase in the ACD and ACV values, and a decrease in the ACA value. However, it had no significant effect on the CCT and keratometry measurements. It is important to consider these effects when using the Pentacam device on young adults with cycloplegia and when applying it for various reasons. Conselho Brasileiro de Oftalmologia2014-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400228Arquivos Brasileiros de Oftalmologia v.77 n.4 2014reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20140059info:eu-repo/semantics/openAccessArici,CeyhunTurk,AdemCeylan,Osman MelihKola,MehmetHurmeric,Volkaneng2014-11-13T00:00:00Zoai:scielo:S0004-27492014000400228Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2014-11-13T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults |
title |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults |
spellingShingle |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults Arici,Ceyhun Biometry Cornea Corneal pachymetry Cyclopentolate/administration and dosage Techniques, measures, measurement equipment |
title_short |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults |
title_full |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults |
title_fullStr |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults |
title_full_unstemmed |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults |
title_sort |
Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults |
author |
Arici,Ceyhun |
author_facet |
Arici,Ceyhun Turk,Adem Ceylan,Osman Melih Kola,Mehmet Hurmeric,Volkan |
author_role |
author |
author2 |
Turk,Adem Ceylan,Osman Melih Kola,Mehmet Hurmeric,Volkan |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Arici,Ceyhun Turk,Adem Ceylan,Osman Melih Kola,Mehmet Hurmeric,Volkan |
dc.subject.por.fl_str_mv |
Biometry Cornea Corneal pachymetry Cyclopentolate/administration and dosage Techniques, measures, measurement equipment |
topic |
Biometry Cornea Corneal pachymetry Cyclopentolate/administration and dosage Techniques, measures, measurement equipment |
description |
Purpose: To investigate the effects of topically applied 1% cyclopentolate hydrochloride on anterior segment parameters obtained with a Pentacam rotating Scheimpflug camera in healthy young adults. Methods: Anterior segment analyses of 25 eyes from 25 young adults (Group 1), before and after 45 min of 1% cyclopentolate hydrochloride application, were performed. For a control group (cycloplegia-free, Group 2), 24 eyes of 24 age- and sex-matched healthy cases were evaluated twice at 45 min intervals. The results obtained from the groups were compared statistically. Results: The mean ages of the groups were 23.04 ± 3.42 (range, 18-29) and 22.4 ± 2.05 (range, 18-27) years for Groups 1 and 2, respectively (p=0.259). In Group 1, measurements between the two analyses were significantly different for the values of anterior chamber depth (ACD), anterior chamber angle (ACA), and anterior chamber volume (ACV) (p<0.05), whereas no statistical difference was found for the central corneal thickness (CCT) and keratometry (K1, K2) measurements. In Group 2, none of these parameters were statistically different between the two analyses. Conclusions: Topically applied 1% cyclopentolate hydrochloride caused an increase in the ACD and ACV values, and a decrease in the ACA value. However, it had no significant effect on the CCT and keratometry measurements. It is important to consider these effects when using the Pentacam device on young adults with cycloplegia and when applying it for various reasons. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400228 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400228 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20140059 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.77 n.4 2014 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209028162977792 |