Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

Detalhes bibliográficos
Autor(a) principal: Ferrer-Blasco,Teresa
Data de Publicação: 2012
Outros Autores: García-Lázaro,Santiago, Albarrán-Diego,César, Belda-Salmerón,Lurdes, Montés-Micó,Robert
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000300009
Resumo: PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively). The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group). CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.
id CBO-2_6477c4fe27c5cbbb0d7d6f7394cd1dfe
oai_identifier_str oai:scielo:S0004-27492012000300009
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Refractive lens exchange with a multifocal diffractive aspheric intraocular lensLens implantation, intraocularLens, crystalline/surgeryMyopia/surgeryHyperopia/physiopathologyPhacoemulsificationProsthesis designTonometry, ocularVisual acuityPURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively). The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group). CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.Conselho Brasileiro de Oftalmologia2012-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000300009Arquivos Brasileiros de Oftalmologia v.75 n.3 2012reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492012000300009info:eu-repo/semantics/openAccessFerrer-Blasco,TeresaGarcía-Lázaro,SantiagoAlbarrán-Diego,CésarBelda-Salmerón,LurdesMontés-Micó,Roberteng2012-08-02T00:00:00Zoai:scielo:S0004-27492012000300009Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2012-08-02T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
title Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
spellingShingle Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
Ferrer-Blasco,Teresa
Lens implantation, intraocular
Lens, crystalline/surgery
Myopia/surgery
Hyperopia/physiopathology
Phacoemulsification
Prosthesis design
Tonometry, ocular
Visual acuity
title_short Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
title_full Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
title_fullStr Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
title_full_unstemmed Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
title_sort Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
author Ferrer-Blasco,Teresa
author_facet Ferrer-Blasco,Teresa
García-Lázaro,Santiago
Albarrán-Diego,César
Belda-Salmerón,Lurdes
Montés-Micó,Robert
author_role author
author2 García-Lázaro,Santiago
Albarrán-Diego,César
Belda-Salmerón,Lurdes
Montés-Micó,Robert
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Ferrer-Blasco,Teresa
García-Lázaro,Santiago
Albarrán-Diego,César
Belda-Salmerón,Lurdes
Montés-Micó,Robert
dc.subject.por.fl_str_mv Lens implantation, intraocular
Lens, crystalline/surgery
Myopia/surgery
Hyperopia/physiopathology
Phacoemulsification
Prosthesis design
Tonometry, ocular
Visual acuity
topic Lens implantation, intraocular
Lens, crystalline/surgery
Myopia/surgery
Hyperopia/physiopathology
Phacoemulsification
Prosthesis design
Tonometry, ocular
Visual acuity
description PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively). The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group). CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.
publishDate 2012
dc.date.none.fl_str_mv 2012-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000300009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000300009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27492012000300009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.75 n.3 2012
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209027276931072