Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study

Detalhes bibliográficos
Autor(a) principal: Jorge,Priscilla de Almeida
Data de Publicação: 2014
Outros Autores: Jorge,Delano, Ventura,Camila Vieira, Ventura,Bruna Vieira, lira,Wagner, Ventura,Marcelo Carvalho, Santhiago,Marcony Rodrigues, Kara-Junior,Newton
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400222
Resumo: Purpose: To evaluate the incidence of posterior capsule opacification (PCO) four years after the implantation of a hydrophilic acrylic intraocular lens (IOL). Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to the IOL implantation, as well as for one month postoperatively. The Student's t-test was used for statistical analysis. Results: The mean age of patients without PCO was 74.6 ± 9.5 years, compared to 70.3 ± 15 years in patients with PCO. Four years after surgery, 39 of the 58 eyes (67%) had detectable PCO and 24 eyes (41.3%) had decreased visual acuity (VA) due to PCO. These patients were referred for Nd:YAG laser capsulotomy. Three patients (5.1%) had decreased VA due to glaucoma, IOL opacification, or age-related macular degeneration. Twelve eyes (20.7%) presented mild PCO with unchanged VA. Systemic arterial hypertension was reported by 45% of the patients, and in 3.5% of these cases this was associated with diabetes mellitus. Conclusion: This study found the incidence of PCO to be 67% four years after phacoemulsification and Ioflex IOL implantation.
id CBO-2_6af2fc0bec33e2a8221ab42756c3a3a0
oai_identifier_str oai:scielo:S0004-27492014000400222
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up studyPosterior capsule of the lensCapsule opacificationPostoperative complicationsCataract/epidemiologyVisual acuity Purpose: To evaluate the incidence of posterior capsule opacification (PCO) four years after the implantation of a hydrophilic acrylic intraocular lens (IOL). Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to the IOL implantation, as well as for one month postoperatively. The Student's t-test was used for statistical analysis. Results: The mean age of patients without PCO was 74.6 ± 9.5 years, compared to 70.3 ± 15 years in patients with PCO. Four years after surgery, 39 of the 58 eyes (67%) had detectable PCO and 24 eyes (41.3%) had decreased visual acuity (VA) due to PCO. These patients were referred for Nd:YAG laser capsulotomy. Three patients (5.1%) had decreased VA due to glaucoma, IOL opacification, or age-related macular degeneration. Twelve eyes (20.7%) presented mild PCO with unchanged VA. Systemic arterial hypertension was reported by 45% of the patients, and in 3.5% of these cases this was associated with diabetes mellitus. Conclusion: This study found the incidence of PCO to be 67% four years after phacoemulsification and Ioflex IOL implantation. Conselho Brasileiro de Oftalmologia2014-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400222Arquivos Brasileiros de Oftalmologia v.77 n.4 2014reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20140057info:eu-repo/semantics/openAccessJorge,Priscilla de AlmeidaJorge,DelanoVentura,Camila VieiraVentura,Bruna Vieiralira,WagnerVentura,Marcelo CarvalhoSanthiago,Marcony RodriguesKara-Junior,Newtoneng2014-11-13T00:00:00Zoai:scielo:S0004-27492014000400222Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2014-11-13T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
title Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
spellingShingle Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
Jorge,Priscilla de Almeida
Posterior capsule of the lens
Capsule opacification
Postoperative complications
Cataract/epidemiology
Visual acuity
title_short Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
title_full Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
title_fullStr Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
title_full_unstemmed Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
title_sort Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study
author Jorge,Priscilla de Almeida
author_facet Jorge,Priscilla de Almeida
Jorge,Delano
Ventura,Camila Vieira
Ventura,Bruna Vieira
lira,Wagner
Ventura,Marcelo Carvalho
Santhiago,Marcony Rodrigues
Kara-Junior,Newton
author_role author
author2 Jorge,Delano
Ventura,Camila Vieira
Ventura,Bruna Vieira
lira,Wagner
Ventura,Marcelo Carvalho
Santhiago,Marcony Rodrigues
Kara-Junior,Newton
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Jorge,Priscilla de Almeida
Jorge,Delano
Ventura,Camila Vieira
Ventura,Bruna Vieira
lira,Wagner
Ventura,Marcelo Carvalho
Santhiago,Marcony Rodrigues
Kara-Junior,Newton
dc.subject.por.fl_str_mv Posterior capsule of the lens
Capsule opacification
Postoperative complications
Cataract/epidemiology
Visual acuity
topic Posterior capsule of the lens
Capsule opacification
Postoperative complications
Cataract/epidemiology
Visual acuity
description Purpose: To evaluate the incidence of posterior capsule opacification (PCO) four years after the implantation of a hydrophilic acrylic intraocular lens (IOL). Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to the IOL implantation, as well as for one month postoperatively. The Student's t-test was used for statistical analysis. Results: The mean age of patients without PCO was 74.6 ± 9.5 years, compared to 70.3 ± 15 years in patients with PCO. Four years after surgery, 39 of the 58 eyes (67%) had detectable PCO and 24 eyes (41.3%) had decreased visual acuity (VA) due to PCO. These patients were referred for Nd:YAG laser capsulotomy. Three patients (5.1%) had decreased VA due to glaucoma, IOL opacification, or age-related macular degeneration. Twelve eyes (20.7%) presented mild PCO with unchanged VA. Systemic arterial hypertension was reported by 45% of the patients, and in 3.5% of these cases this was associated with diabetes mellitus. Conclusion: This study found the incidence of PCO to be 67% four years after phacoemulsification and Ioflex IOL implantation.
publishDate 2014
dc.date.none.fl_str_mv 2014-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400222
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400222
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20140057
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.77 n.4 2014
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209028158783488