Human cornea conservation in coconut water solution
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163 |
Resumo: | ABSTRACT Purpose: The aim of this study was to evaluate the physical and chemical characteristics of coconut water and to analyze the use of coconut water solution for the conservation of human corneas. Methods: This was an experimental and controlled study performed at the Eye Bank of the General Hospital of Fortaleza. The coconut water-based solution was prepared at the Goat Seed Technology Laboratory of the Department of Veterinary Medicine of the State University of Ceará. Discarded corneas from the Eye Bank were divided into two groups for sequential experiments: G1, coconut water-based solution (experimental group), and G2, conservative treatment with OPTISOL GS® (control group). The osmolality of corneas in G1 was analyzed sequentially at 275, 300, 325, 345, 365, and 400 mOsm/L. The viability of the corneas was determined by specular microscopy and biomicroscopy on the first, third, and seventh days. Results: Corneas preserved in a solution of 365 and 345 mOsm/L had a transparency of 8 mm until the third day and had diffuse edema in the periphery, central folds, and partial epithelium loss until the seventh day. The 365-mOsm/L solution was associated with the worst results during follow-up. Corneas placed in Optisol-GS retained their original aspects. Conclusions: Coconut water-based preservative partially maintained corneal transparency and epithelial integrity, especially during the first three days of follow-up. The coconut water-based solutions used were not effective for use as preservatives in a human eye bank. |
id |
CBO-2_731dbc2dfa15801bc3d2fefd1ce8c13f |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492021000200163 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Human cornea conservation in coconut water solutionCorneaCoconut waterOrgan preservation/methodsOrgan preservation solutionBiotechnologyABSTRACT Purpose: The aim of this study was to evaluate the physical and chemical characteristics of coconut water and to analyze the use of coconut water solution for the conservation of human corneas. Methods: This was an experimental and controlled study performed at the Eye Bank of the General Hospital of Fortaleza. The coconut water-based solution was prepared at the Goat Seed Technology Laboratory of the Department of Veterinary Medicine of the State University of Ceará. Discarded corneas from the Eye Bank were divided into two groups for sequential experiments: G1, coconut water-based solution (experimental group), and G2, conservative treatment with OPTISOL GS® (control group). The osmolality of corneas in G1 was analyzed sequentially at 275, 300, 325, 345, 365, and 400 mOsm/L. The viability of the corneas was determined by specular microscopy and biomicroscopy on the first, third, and seventh days. Results: Corneas preserved in a solution of 365 and 345 mOsm/L had a transparency of 8 mm until the third day and had diffuse edema in the periphery, central folds, and partial epithelium loss until the seventh day. The 365-mOsm/L solution was associated with the worst results during follow-up. Corneas placed in Optisol-GS retained their original aspects. Conclusions: Coconut water-based preservative partially maintained corneal transparency and epithelial integrity, especially during the first three days of follow-up. The coconut water-based solutions used were not effective for use as preservatives in a human eye bank.Conselho Brasileiro de Oftalmologia2021-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163Arquivos Brasileiros de Oftalmologia v.84 n.2 2021reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20210027info:eu-repo/semantics/openAccessCid,David Antonio CameloAraújo,Marília CavalcantePassos,Márcia Vitorino SampaioBrasil,Ivelise Regina CanitoNunes,José FerreiraSalgueiro,Cristiane Clemente de MeloNogueira,Sávio CarvalhoCosta,Dácio Carvalhoeng2021-03-23T00:00:00Zoai:scielo:S0004-27492021000200163Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2021-03-23T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Human cornea conservation in coconut water solution |
title |
Human cornea conservation in coconut water solution |
spellingShingle |
Human cornea conservation in coconut water solution Cid,David Antonio Camelo Cornea Coconut water Organ preservation/methods Organ preservation solution Biotechnology |
title_short |
Human cornea conservation in coconut water solution |
title_full |
Human cornea conservation in coconut water solution |
title_fullStr |
Human cornea conservation in coconut water solution |
title_full_unstemmed |
Human cornea conservation in coconut water solution |
title_sort |
Human cornea conservation in coconut water solution |
author |
Cid,David Antonio Camelo |
author_facet |
Cid,David Antonio Camelo Araújo,Marília Cavalcante Passos,Márcia Vitorino Sampaio Brasil,Ivelise Regina Canito Nunes,José Ferreira Salgueiro,Cristiane Clemente de Melo Nogueira,Sávio Carvalho Costa,Dácio Carvalho |
author_role |
author |
author2 |
Araújo,Marília Cavalcante Passos,Márcia Vitorino Sampaio Brasil,Ivelise Regina Canito Nunes,José Ferreira Salgueiro,Cristiane Clemente de Melo Nogueira,Sávio Carvalho Costa,Dácio Carvalho |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Cid,David Antonio Camelo Araújo,Marília Cavalcante Passos,Márcia Vitorino Sampaio Brasil,Ivelise Regina Canito Nunes,José Ferreira Salgueiro,Cristiane Clemente de Melo Nogueira,Sávio Carvalho Costa,Dácio Carvalho |
dc.subject.por.fl_str_mv |
Cornea Coconut water Organ preservation/methods Organ preservation solution Biotechnology |
topic |
Cornea Coconut water Organ preservation/methods Organ preservation solution Biotechnology |
description |
ABSTRACT Purpose: The aim of this study was to evaluate the physical and chemical characteristics of coconut water and to analyze the use of coconut water solution for the conservation of human corneas. Methods: This was an experimental and controlled study performed at the Eye Bank of the General Hospital of Fortaleza. The coconut water-based solution was prepared at the Goat Seed Technology Laboratory of the Department of Veterinary Medicine of the State University of Ceará. Discarded corneas from the Eye Bank were divided into two groups for sequential experiments: G1, coconut water-based solution (experimental group), and G2, conservative treatment with OPTISOL GS® (control group). The osmolality of corneas in G1 was analyzed sequentially at 275, 300, 325, 345, 365, and 400 mOsm/L. The viability of the corneas was determined by specular microscopy and biomicroscopy on the first, third, and seventh days. Results: Corneas preserved in a solution of 365 and 345 mOsm/L had a transparency of 8 mm until the third day and had diffuse edema in the periphery, central folds, and partial epithelium loss until the seventh day. The 365-mOsm/L solution was associated with the worst results during follow-up. Corneas placed in Optisol-GS retained their original aspects. Conclusions: Coconut water-based preservative partially maintained corneal transparency and epithelial integrity, especially during the first three days of follow-up. The coconut water-based solutions used were not effective for use as preservatives in a human eye bank. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20210027 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.84 n.2 2021 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209031307657216 |