Human cornea conservation in coconut water solution

Detalhes bibliográficos
Autor(a) principal: Cid,David Antonio Camelo
Data de Publicação: 2021
Outros Autores: Araújo,Marília Cavalcante, Passos,Márcia Vitorino Sampaio, Brasil,Ivelise Regina Canito, Nunes,José Ferreira, Salgueiro,Cristiane Clemente de Melo, Nogueira,Sávio Carvalho, Costa,Dácio Carvalho
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163
Resumo: ABSTRACT Purpose: The aim of this study was to evaluate the physical and chemical characteristics of coconut water and to analyze the use of coconut water solution for the conservation of human corneas. Methods: This was an experimental and controlled study performed at the Eye Bank of the General Hospital of Fortaleza. The coconut water-based solution was prepared at the Goat Seed Technology Laboratory of the Department of Veterinary Medicine of the State University of Ceará. Discarded corneas from the Eye Bank were divided into two groups for sequential experiments: G1, coconut water-based solution (experimental group), and G2, conservative treatment with OPTISOL GS® (control group). The osmolality of corneas in G1 was analyzed sequentially at 275, 300, 325, 345, 365, and 400 mOsm/L. The viability of the corneas was determined by specular microscopy and biomicroscopy on the first, third, and seventh days. Results: Corneas preserved in a solution of 365 and 345 mOsm/L had a transparency of 8 mm until the third day and had diffuse edema in the periphery, central folds, and partial epithelium loss until the seventh day. The 365-mOsm/L solution was associated with the worst results during follow-up. Corneas placed in Optisol-GS retained their original aspects. Conclusions: Coconut water-based preservative partially maintained corneal transparency and epithelial integrity, especially during the first three days of follow-up. The coconut water-based solutions used were not effective for use as preservatives in a human eye bank.
id CBO-2_731dbc2dfa15801bc3d2fefd1ce8c13f
oai_identifier_str oai:scielo:S0004-27492021000200163
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Human cornea conservation in coconut water solutionCorneaCoconut waterOrgan preservation/methodsOrgan preservation solutionBiotechnologyABSTRACT Purpose: The aim of this study was to evaluate the physical and chemical characteristics of coconut water and to analyze the use of coconut water solution for the conservation of human corneas. Methods: This was an experimental and controlled study performed at the Eye Bank of the General Hospital of Fortaleza. The coconut water-based solution was prepared at the Goat Seed Technology Laboratory of the Department of Veterinary Medicine of the State University of Ceará. Discarded corneas from the Eye Bank were divided into two groups for sequential experiments: G1, coconut water-based solution (experimental group), and G2, conservative treatment with OPTISOL GS® (control group). The osmolality of corneas in G1 was analyzed sequentially at 275, 300, 325, 345, 365, and 400 mOsm/L. The viability of the corneas was determined by specular microscopy and biomicroscopy on the first, third, and seventh days. Results: Corneas preserved in a solution of 365 and 345 mOsm/L had a transparency of 8 mm until the third day and had diffuse edema in the periphery, central folds, and partial epithelium loss until the seventh day. The 365-mOsm/L solution was associated with the worst results during follow-up. Corneas placed in Optisol-GS retained their original aspects. Conclusions: Coconut water-based preservative partially maintained corneal transparency and epithelial integrity, especially during the first three days of follow-up. The coconut water-based solutions used were not effective for use as preservatives in a human eye bank.Conselho Brasileiro de Oftalmologia2021-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163Arquivos Brasileiros de Oftalmologia v.84 n.2 2021reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20210027info:eu-repo/semantics/openAccessCid,David Antonio CameloAraújo,Marília CavalcantePassos,Márcia Vitorino SampaioBrasil,Ivelise Regina CanitoNunes,José FerreiraSalgueiro,Cristiane Clemente de MeloNogueira,Sávio CarvalhoCosta,Dácio Carvalhoeng2021-03-23T00:00:00Zoai:scielo:S0004-27492021000200163Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2021-03-23T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Human cornea conservation in coconut water solution
title Human cornea conservation in coconut water solution
spellingShingle Human cornea conservation in coconut water solution
Cid,David Antonio Camelo
Cornea
Coconut water
Organ preservation/methods
Organ preservation solution
Biotechnology
title_short Human cornea conservation in coconut water solution
title_full Human cornea conservation in coconut water solution
title_fullStr Human cornea conservation in coconut water solution
title_full_unstemmed Human cornea conservation in coconut water solution
title_sort Human cornea conservation in coconut water solution
author Cid,David Antonio Camelo
author_facet Cid,David Antonio Camelo
Araújo,Marília Cavalcante
Passos,Márcia Vitorino Sampaio
Brasil,Ivelise Regina Canito
Nunes,José Ferreira
Salgueiro,Cristiane Clemente de Melo
Nogueira,Sávio Carvalho
Costa,Dácio Carvalho
author_role author
author2 Araújo,Marília Cavalcante
Passos,Márcia Vitorino Sampaio
Brasil,Ivelise Regina Canito
Nunes,José Ferreira
Salgueiro,Cristiane Clemente de Melo
Nogueira,Sávio Carvalho
Costa,Dácio Carvalho
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Cid,David Antonio Camelo
Araújo,Marília Cavalcante
Passos,Márcia Vitorino Sampaio
Brasil,Ivelise Regina Canito
Nunes,José Ferreira
Salgueiro,Cristiane Clemente de Melo
Nogueira,Sávio Carvalho
Costa,Dácio Carvalho
dc.subject.por.fl_str_mv Cornea
Coconut water
Organ preservation/methods
Organ preservation solution
Biotechnology
topic Cornea
Coconut water
Organ preservation/methods
Organ preservation solution
Biotechnology
description ABSTRACT Purpose: The aim of this study was to evaluate the physical and chemical characteristics of coconut water and to analyze the use of coconut water solution for the conservation of human corneas. Methods: This was an experimental and controlled study performed at the Eye Bank of the General Hospital of Fortaleza. The coconut water-based solution was prepared at the Goat Seed Technology Laboratory of the Department of Veterinary Medicine of the State University of Ceará. Discarded corneas from the Eye Bank were divided into two groups for sequential experiments: G1, coconut water-based solution (experimental group), and G2, conservative treatment with OPTISOL GS® (control group). The osmolality of corneas in G1 was analyzed sequentially at 275, 300, 325, 345, 365, and 400 mOsm/L. The viability of the corneas was determined by specular microscopy and biomicroscopy on the first, third, and seventh days. Results: Corneas preserved in a solution of 365 and 345 mOsm/L had a transparency of 8 mm until the third day and had diffuse edema in the periphery, central folds, and partial epithelium loss until the seventh day. The 365-mOsm/L solution was associated with the worst results during follow-up. Corneas placed in Optisol-GS retained their original aspects. Conclusions: Coconut water-based preservative partially maintained corneal transparency and epithelial integrity, especially during the first three days of follow-up. The coconut water-based solutions used were not effective for use as preservatives in a human eye bank.
publishDate 2021
dc.date.none.fl_str_mv 2021-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200163
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20210027
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.84 n.2 2021
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209031307657216