Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report

Detalhes bibliográficos
Autor(a) principal: Hida,Wilson Takashi
Data de Publicação: 2012
Outros Autores: Motta,Antonio Francisco, Nakano,Celso Takashi, Tzelikis,Patrick F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000600012
Resumo: A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL) implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.
id CBO-2_98e89c953cb5d60d58799d1585994058
oai_identifier_str oai:scielo:S0004-27492012000600012
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case reportLens implantation, intraocular/adverse effectsVisual acuityCase reportA 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL) implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.Conselho Brasileiro de Oftalmologia2012-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000600012Arquivos Brasileiros de Oftalmologia v.75 n.6 2012reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492012000600012info:eu-repo/semantics/openAccessHida,Wilson TakashiMotta,Antonio FranciscoNakano,Celso TakashiTzelikis,Patrick F.eng2013-05-23T00:00:00Zoai:scielo:S0004-27492012000600012Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2013-05-23T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
title Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
spellingShingle Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
Hida,Wilson Takashi
Lens implantation, intraocular/adverse effects
Visual acuity
Case report
title_short Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
title_full Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
title_fullStr Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
title_full_unstemmed Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
title_sort Inadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report
author Hida,Wilson Takashi
author_facet Hida,Wilson Takashi
Motta,Antonio Francisco
Nakano,Celso Takashi
Tzelikis,Patrick F.
author_role author
author2 Motta,Antonio Francisco
Nakano,Celso Takashi
Tzelikis,Patrick F.
author2_role author
author
author
dc.contributor.author.fl_str_mv Hida,Wilson Takashi
Motta,Antonio Francisco
Nakano,Celso Takashi
Tzelikis,Patrick F.
dc.subject.por.fl_str_mv Lens implantation, intraocular/adverse effects
Visual acuity
Case report
topic Lens implantation, intraocular/adverse effects
Visual acuity
Case report
description A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL) implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eyes was 20/20 and neither complained of visual discomfort. In conclusion, we found that a reversed-optic Tecnis multifocal IOL in the present case resulted in good final visual acuity without significant differences in aberrations compared to the other eye, and a conservative management can be taken as a safe option.
publishDate 2012
dc.date.none.fl_str_mv 2012-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000600012
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000600012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27492012000600012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.75 n.6 2012
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209027632398336