Corneal biomechanical features in patients with ankylosing spondylitis

Detalhes bibliográficos
Autor(a) principal: Cabuk,Kubra Serefoglu
Data de Publicação: 2017
Outros Autores: Üstün,Emine Isil, Atalay,Kursat, Kirgiz,Ahmet, Aydin,Rukiye
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000500009
Resumo: ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.
id CBO-2_9b1cf74985e213fd6cc9faae5a73584b
oai_identifier_str oai:scielo:S0004-27492017000500009
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Corneal biomechanical features in patients with ankylosing spondylitisSpondylitis, ankylosingCorneal biomechanicsCorneal tomographySeverity of illness indexABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.Conselho Brasileiro de Oftalmologia2017-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000500009Arquivos Brasileiros de Oftalmologia v.80 n.5 2017reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20170075info:eu-repo/semantics/openAccessCabuk,Kubra SerefogluÜstün,Emine IsilAtalay,KursatKirgiz,AhmetAydin,Rukiyeeng2017-11-09T00:00:00Zoai:scielo:S0004-27492017000500009Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2017-11-09T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Corneal biomechanical features in patients with ankylosing spondylitis
title Corneal biomechanical features in patients with ankylosing spondylitis
spellingShingle Corneal biomechanical features in patients with ankylosing spondylitis
Cabuk,Kubra Serefoglu
Spondylitis, ankylosing
Corneal biomechanics
Corneal tomography
Severity of illness index
title_short Corneal biomechanical features in patients with ankylosing spondylitis
title_full Corneal biomechanical features in patients with ankylosing spondylitis
title_fullStr Corneal biomechanical features in patients with ankylosing spondylitis
title_full_unstemmed Corneal biomechanical features in patients with ankylosing spondylitis
title_sort Corneal biomechanical features in patients with ankylosing spondylitis
author Cabuk,Kubra Serefoglu
author_facet Cabuk,Kubra Serefoglu
Üstün,Emine Isil
Atalay,Kursat
Kirgiz,Ahmet
Aydin,Rukiye
author_role author
author2 Üstün,Emine Isil
Atalay,Kursat
Kirgiz,Ahmet
Aydin,Rukiye
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Cabuk,Kubra Serefoglu
Üstün,Emine Isil
Atalay,Kursat
Kirgiz,Ahmet
Aydin,Rukiye
dc.subject.por.fl_str_mv Spondylitis, ankylosing
Corneal biomechanics
Corneal tomography
Severity of illness index
topic Spondylitis, ankylosing
Corneal biomechanics
Corneal tomography
Severity of illness index
description ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.
publishDate 2017
dc.date.none.fl_str_mv 2017-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000500009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492017000500009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20170075
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.80 n.5 2017
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209029499912192