Validation of a new fiber electrode prototype for clinical electroretinography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492008000300003 |
Resumo: | PURPOSE: To validate a new fiber electrode prototype for clinical electroretinography (ERG). METHODS: A recently developed prototype of a disposable reference-coupled fiber electrode (patent pending Brazilian Institute of Industrial Property # PI0602186-7), including one fiber for corneal signals and a second fiber acting as reference was tested in a group of 20 healthy volunteers (17-31 years; mean 22.7 ± 4.5; 8 males). Standard electroretinography rod and cone responses were recorded from a fully dilated pupil simultaneously in both eyes with a reference-coupled fiber electrode prototype in one randomly assigned eye and a DTL® electrode in the other eye after 30 min of dark-adaptation. After presenting dark- and light-adapted stimuli, each response was analyzed for a- and b-wave amplitude and implicit time. The VERIS 5.1.9 system was used for electroretinography data acquisition and analysis. Electroretinography outcomes were analyzed by Mann-Whitney test. Slit-lamp examination was performed in both eyes right after electroretinography session to evaluate possible adverse effects. RESULTS: Responses recorded with reference-coupled fiber electrode prototypes were comparable to commercially available DTL® fiber electrodes. On a qualitative analysis, reference-coupled fiber electrodes provided recordings with less amount of noise. On average, scotopic electroretinography amplitude and b-wave implicit time recorded using DTL® were, respectively, 287.6 µV and 36.3 ms with similar findings for the reference-coupled fiber electrode prototype (287.9 µV and 36.3 ms). Under photopic conditions DTL® mean amplitude and implicit time were, respectively 108.9 µV and 24.5 ms with similar results for the reference-coupled fiber electrodes prototypes (116.4 µV and 24.5 ms). No corneal abrasions or any other significant adverse effects were found after electroretinography recording with both electrodes. CONCLUSIONS: The reference-coupled fiber electrode prototype provided stable and safe recordings of corneal electroretinograms compared to the commercially availabe DTL® electrode in healthy human subjects. The prototype is a feasible alternative instrument for clinical electroretinography recording to assess retinal function, however further analysis is recommended to validate its clinical usefulness in patients with retinal disorders. |
id |
CBO-2_9f5d9aa86dec13d1efd7c87a50d29cc9 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492008000300003 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Validation of a new fiber electrode prototype for clinical electroretinographyElectrodesElectroretinography/instrumentationRetina/physiologyRetinal diseasesValidation studiesPURPOSE: To validate a new fiber electrode prototype for clinical electroretinography (ERG). METHODS: A recently developed prototype of a disposable reference-coupled fiber electrode (patent pending Brazilian Institute of Industrial Property # PI0602186-7), including one fiber for corneal signals and a second fiber acting as reference was tested in a group of 20 healthy volunteers (17-31 years; mean 22.7 ± 4.5; 8 males). Standard electroretinography rod and cone responses were recorded from a fully dilated pupil simultaneously in both eyes with a reference-coupled fiber electrode prototype in one randomly assigned eye and a DTL® electrode in the other eye after 30 min of dark-adaptation. After presenting dark- and light-adapted stimuli, each response was analyzed for a- and b-wave amplitude and implicit time. The VERIS 5.1.9 system was used for electroretinography data acquisition and analysis. Electroretinography outcomes were analyzed by Mann-Whitney test. Slit-lamp examination was performed in both eyes right after electroretinography session to evaluate possible adverse effects. RESULTS: Responses recorded with reference-coupled fiber electrode prototypes were comparable to commercially available DTL® fiber electrodes. On a qualitative analysis, reference-coupled fiber electrodes provided recordings with less amount of noise. On average, scotopic electroretinography amplitude and b-wave implicit time recorded using DTL® were, respectively, 287.6 µV and 36.3 ms with similar findings for the reference-coupled fiber electrode prototype (287.9 µV and 36.3 ms). Under photopic conditions DTL® mean amplitude and implicit time were, respectively 108.9 µV and 24.5 ms with similar results for the reference-coupled fiber electrodes prototypes (116.4 µV and 24.5 ms). No corneal abrasions or any other significant adverse effects were found after electroretinography recording with both electrodes. CONCLUSIONS: The reference-coupled fiber electrode prototype provided stable and safe recordings of corneal electroretinograms compared to the commercially availabe DTL® electrode in healthy human subjects. The prototype is a feasible alternative instrument for clinical electroretinography recording to assess retinal function, however further analysis is recommended to validate its clinical usefulness in patients with retinal disorders.Conselho Brasileiro de Oftalmologia2008-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492008000300003Arquivos Brasileiros de Oftalmologia v.71 n.3 2008reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492008000300003info:eu-repo/semantics/openAccessBerezovsky,AdrianaPereira,Josenilson MartinsSalomão,Solange RiosSantos,Vagner Rogério dosSchor,Pauloeng2008-07-15T00:00:00Zoai:scielo:S0004-27492008000300003Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2008-07-15T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Validation of a new fiber electrode prototype for clinical electroretinography |
title |
Validation of a new fiber electrode prototype for clinical electroretinography |
spellingShingle |
Validation of a new fiber electrode prototype for clinical electroretinography Berezovsky,Adriana Electrodes Electroretinography/instrumentation Retina/physiology Retinal diseases Validation studies |
title_short |
Validation of a new fiber electrode prototype for clinical electroretinography |
title_full |
Validation of a new fiber electrode prototype for clinical electroretinography |
title_fullStr |
Validation of a new fiber electrode prototype for clinical electroretinography |
title_full_unstemmed |
Validation of a new fiber electrode prototype for clinical electroretinography |
title_sort |
Validation of a new fiber electrode prototype for clinical electroretinography |
author |
Berezovsky,Adriana |
author_facet |
Berezovsky,Adriana Pereira,Josenilson Martins Salomão,Solange Rios Santos,Vagner Rogério dos Schor,Paulo |
author_role |
author |
author2 |
Pereira,Josenilson Martins Salomão,Solange Rios Santos,Vagner Rogério dos Schor,Paulo |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Berezovsky,Adriana Pereira,Josenilson Martins Salomão,Solange Rios Santos,Vagner Rogério dos Schor,Paulo |
dc.subject.por.fl_str_mv |
Electrodes Electroretinography/instrumentation Retina/physiology Retinal diseases Validation studies |
topic |
Electrodes Electroretinography/instrumentation Retina/physiology Retinal diseases Validation studies |
description |
PURPOSE: To validate a new fiber electrode prototype for clinical electroretinography (ERG). METHODS: A recently developed prototype of a disposable reference-coupled fiber electrode (patent pending Brazilian Institute of Industrial Property # PI0602186-7), including one fiber for corneal signals and a second fiber acting as reference was tested in a group of 20 healthy volunteers (17-31 years; mean 22.7 ± 4.5; 8 males). Standard electroretinography rod and cone responses were recorded from a fully dilated pupil simultaneously in both eyes with a reference-coupled fiber electrode prototype in one randomly assigned eye and a DTL® electrode in the other eye after 30 min of dark-adaptation. After presenting dark- and light-adapted stimuli, each response was analyzed for a- and b-wave amplitude and implicit time. The VERIS 5.1.9 system was used for electroretinography data acquisition and analysis. Electroretinography outcomes were analyzed by Mann-Whitney test. Slit-lamp examination was performed in both eyes right after electroretinography session to evaluate possible adverse effects. RESULTS: Responses recorded with reference-coupled fiber electrode prototypes were comparable to commercially available DTL® fiber electrodes. On a qualitative analysis, reference-coupled fiber electrodes provided recordings with less amount of noise. On average, scotopic electroretinography amplitude and b-wave implicit time recorded using DTL® were, respectively, 287.6 µV and 36.3 ms with similar findings for the reference-coupled fiber electrode prototype (287.9 µV and 36.3 ms). Under photopic conditions DTL® mean amplitude and implicit time were, respectively 108.9 µV and 24.5 ms with similar results for the reference-coupled fiber electrodes prototypes (116.4 µV and 24.5 ms). No corneal abrasions or any other significant adverse effects were found after electroretinography recording with both electrodes. CONCLUSIONS: The reference-coupled fiber electrode prototype provided stable and safe recordings of corneal electroretinograms compared to the commercially availabe DTL® electrode in healthy human subjects. The prototype is a feasible alternative instrument for clinical electroretinography recording to assess retinal function, however further analysis is recommended to validate its clinical usefulness in patients with retinal disorders. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492008000300003 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492008000300003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-27492008000300003 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.71 n.3 2008 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209025058144256 |