Resumo: | PURPOSE: A microdevice for the treatment of refractory glaucoma is presented. The underlying concepts, its mechanisms of action and the surgical technique for implanting are explained and the results are analyzed. The microdevice was developed and the surgeries were performed at the Maldonado-Bas Eye Clinic (Cordoba, Argentina), under the rules established in the protocol approved by the provisions of the National Administration of Drugs, Food and Medical Technology 430/7. File No.:1-47-25-649-07-1. METHODS: In a prospective study, following the protocol, 16 eyes with refractory glaucoma were included and operated. Intraocular pressure <21mmHg with or without additional medication was considered successful. The follow-up was one year. Averages, percentages and their 95% confidence bands were calculated. Analysis of variance for repeated measures was used to compare averages. RESULTS: The average preoperative intraocular pressure was 32.81 mmHg, SD ± 10.94 mmHg in a range of 14 to 50 mmHg. The average post-surgical intraocular pressure at one year was 12.43 mmHg, SD ± 2.85 mmHg in a range of 7 to 19 mmHg. The difference between the pre-and post-surgery average intraocular pressure was 20.38 mmHg. The number of successes was 14 eyes (87.5%, confidence interval (CI) 95% 61.6% - 98.6%). The number of failures was two eyes (12.5%, CI 95% 1.43% - 38.4%). CONCLUSIONS: The results show that the microdevice is successful for the treatment of refractory glaucoma. |
id |
CBO-2_d47f54e3be1df81c770d2488229425d6 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492011000300011 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Microdevice for aqueous humor drainage Maldonado Bas - PförtnerGlaucoma/surgeryFiltering surgeryIntraocular pressureTrabeculectomy/methodsAqueous humorOptical devicesSclera/surgerySclerostomyPURPOSE: A microdevice for the treatment of refractory glaucoma is presented. The underlying concepts, its mechanisms of action and the surgical technique for implanting are explained and the results are analyzed. The microdevice was developed and the surgeries were performed at the Maldonado-Bas Eye Clinic (Cordoba, Argentina), under the rules established in the protocol approved by the provisions of the National Administration of Drugs, Food and Medical Technology 430/7. File No.:1-47-25-649-07-1. METHODS: In a prospective study, following the protocol, 16 eyes with refractory glaucoma were included and operated. Intraocular pressure <21mmHg with or without additional medication was considered successful. The follow-up was one year. Averages, percentages and their 95% confidence bands were calculated. Analysis of variance for repeated measures was used to compare averages. RESULTS: The average preoperative intraocular pressure was 32.81 mmHg, SD ± 10.94 mmHg in a range of 14 to 50 mmHg. The average post-surgical intraocular pressure at one year was 12.43 mmHg, SD ± 2.85 mmHg in a range of 7 to 19 mmHg. The difference between the pre-and post-surgery average intraocular pressure was 20.38 mmHg. The number of successes was 14 eyes (87.5%, confidence interval (CI) 95% 61.6% - 98.6%). The number of failures was two eyes (12.5%, CI 95% 1.43% - 38.4%). CONCLUSIONS: The results show that the microdevice is successful for the treatment of refractory glaucoma.Conselho Brasileiro de Oftalmologia2011-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492011000300011Arquivos Brasileiros de Oftalmologia v.74 n.3 2011reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492011000300011info:eu-repo/semantics/openAccessMaldonado-Bas,ArturoMaldonado-Junyent,AnaMaldonado-Junyent,Arturoeng2011-09-02T00:00:00Zoai:scielo:S0004-27492011000300011Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2011-09-02T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner |
title |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner |
spellingShingle |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner Maldonado-Bas,Arturo Glaucoma/surgery Filtering surgery Intraocular pressure Trabeculectomy/methods Aqueous humor Optical devices Sclera/surgery Sclerostomy |
title_short |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner |
title_full |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner |
title_fullStr |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner |
title_full_unstemmed |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner |
title_sort |
Microdevice for aqueous humor drainage Maldonado Bas - Pförtner |
author |
Maldonado-Bas,Arturo |
author_facet |
Maldonado-Bas,Arturo Maldonado-Junyent,Ana Maldonado-Junyent,Arturo |
author_role |
author |
author2 |
Maldonado-Junyent,Ana Maldonado-Junyent,Arturo |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Maldonado-Bas,Arturo Maldonado-Junyent,Ana Maldonado-Junyent,Arturo |
dc.subject.por.fl_str_mv |
Glaucoma/surgery Filtering surgery Intraocular pressure Trabeculectomy/methods Aqueous humor Optical devices Sclera/surgery Sclerostomy |
topic |
Glaucoma/surgery Filtering surgery Intraocular pressure Trabeculectomy/methods Aqueous humor Optical devices Sclera/surgery Sclerostomy |
description |
PURPOSE: A microdevice for the treatment of refractory glaucoma is presented. The underlying concepts, its mechanisms of action and the surgical technique for implanting are explained and the results are analyzed. The microdevice was developed and the surgeries were performed at the Maldonado-Bas Eye Clinic (Cordoba, Argentina), under the rules established in the protocol approved by the provisions of the National Administration of Drugs, Food and Medical Technology 430/7. File No.:1-47-25-649-07-1. METHODS: In a prospective study, following the protocol, 16 eyes with refractory glaucoma were included and operated. Intraocular pressure <21mmHg with or without additional medication was considered successful. The follow-up was one year. Averages, percentages and their 95% confidence bands were calculated. Analysis of variance for repeated measures was used to compare averages. RESULTS: The average preoperative intraocular pressure was 32.81 mmHg, SD ± 10.94 mmHg in a range of 14 to 50 mmHg. The average post-surgical intraocular pressure at one year was 12.43 mmHg, SD ± 2.85 mmHg in a range of 7 to 19 mmHg. The difference between the pre-and post-surgery average intraocular pressure was 20.38 mmHg. The number of successes was 14 eyes (87.5%, confidence interval (CI) 95% 61.6% - 98.6%). The number of failures was two eyes (12.5%, CI 95% 1.43% - 38.4%). CONCLUSIONS: The results show that the microdevice is successful for the treatment of refractory glaucoma. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492011000300011 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492011000300011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-27492011000300011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.74 n.3 2011 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209026849112064 |